Clipsal - Max 4 Mini Neutral link 100 A 500 V 8 hole with cover front wiring Black
Item Number: L8
Specifications
Design
Range
Product brand
Range of product
Product or component type
Physical
[in] rated current
[ue] rated operational voltage
Connector type
Number of poles
Height
Width
Depth
Reach regulation
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Circularity profile
Others
Package 1 bare product quantity
Cable cross section
Number of mounting holes
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Take-back
Product contributes to saved and avoided emissions
Removable battery
Documents & downloads
hide show-
All
-
Technical Data Catalogues
-
Specification Guide
Frequently Asked Questions
hide showUnder Visualization Parameter
tick the Vertical slider and invert the vertical slider option to flip the horizontal slider to a vertical slider icon
Tick inver vertical slider
Potential issues caused by having >2A limit are:
Damage to the C-Bus cat-5 cable if a dead short were to occur
Impedance causing unstable communications
Potential stressing of power supply units
The C-Bus Cat-5 (cable) must not carry current in excess of 2 A (this is the Maximum C-Bus Current per Network).
Either reduce the number of C-Bus power supply or split the network by using a network bridge(5500NB) in this case.
C-Bus Hardware Installation.pdf
C-Bus™ Products Training Course Training Guide.pdf
How to adjust PowerPact P or R or Masterpact circuit breakers with Micrologic trip units to a different Amp rating?
Product Line:
PowerPact P, PowerPact R, Masterpact NW, Masterpact NT
Resolution:
The attached spreadsheet gives you the sensor plug and Long Time (rating plug) settings that will set the breaker to any amperage within its range.
Note that many amp settings can be attained with more than one rating plug and sensor combination.
Sensor plugs can be changed to a lower amperage in some cases; they cannot be increased from the original size, but they can be reduced as much as 50%.
It is not possible to put a 100A or 250A sensor in a 400A or larger breaker. 400A and larger breakers cannot accept 100A or 250A sensors.
See circuit breaker section of the digest for a chart showing possible sensor plugs for breakers 3200A and under.
Sensor Plug Replacement Guide attached includes references for amperages above 3200A.
Scenario: You want to use a C-Bus motion SENSOR to trigger a scene stored on another device i.e C-Bus switch when it turns ON and then trigger a second scene when it times OUT and turns OFF.
Mandatory: The C-Bus switch will need to have built in scene and virtual keys (switch firmware >= v2.0.00)
The motion detector to trigger scenes needs to utilise the secondary application (trigger control)
C-Bus Sensor secondary application is set to Trigger control and the Key1 is then select to set to trigger secondary application by clicking on the P(Primary application) it will change to S(secondary application).
The Trigger Group will need to be the same (common) to trigger both scenes - and its the value of the trigger group that acts as the action selector telling the triggered scene which action is being triggered.
The scenes will be stored in a KEYE4.
Action Selector 0 means that Scene 1 will trigger when Trigger Group 0 is at 0 (OFF) level and
Action Selector 255 means that Scene 2 will trigger when Trigger Group 0 is at 255 (ON) level.
Looking for a transformer or power supply to convert DC to AC
Product Line:
Phaseo ABL8 Power Supply
Environment:
Phaseo Power Supply
Cause:
Will backfeeding an ABL8 DC power supply allow DC voltage to convert to AC?
Resolution:
No, these are not intended to be used in this manner. A DC rectifier will need to be used
Over 7-10 years the battery requires replacing else if there is a power failure you’re risking losing time and all programming on the unit.
The replacement battery is CR2477N
Issue:
Needs environmental data for ABL8WPS24200 and ABL8WPS24400.
Product Line:
Relays and Timers
Environment:
ABL Phaseo Power Supplies
Resolution:
Per expanded catalog DIA3ED207041EN-US, page 30, "-13°F to 140°F with derating from 122 °F or (-25 to +60 derating from 50°C)".