This MAX4 accessory is a screw mounted neutral link. it is a 1P, rated current is 100A, and rated operational voltage is 500VAC. The cable cross section capacity goes up to 16-16mm². The color of the neutral link is black.

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

MAX9

Product brand

Clipsal

Range of product

Blue Point

Product or component type

neutral link

Physical

[in] rated current

100 A

[ue] rated operational voltage

500 V

Connector type

screw terminals

Number of poles

1

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Rohs exemption information

Yes

Circularity profile

N/A

Others

Package 1 bare product quantity

1

Cable cross section

16 mm²

Number of mounting holes

5

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

5.1 cm

Package 1 width

4.6 cm

Package 1 length

6.5 cm

Package 1 weight

68.0 g
Show all specifications

Frequently Asked Questions

hide show

I want to put in two-way switching but can’t run the cables between the mechanisms. Can I achieve wireless two-way switching with Wiser Zigbee?

This can be done with our 2AX, 10AX or Micro Module Switch along with the Hub. At one end you will need an Active, Neutral and Load wiring. At the other end you will need Active and Neutral only. You can then create Automations to achieve the 2-way.
You need to create two automations for a 2-way:
 
  1. when switch A and switch B are ON, turn switch A and switch B ON
  2. when switch A and switch B are OFF, turn switch A and switch B OFF


This can be expanded to 3-way, 4-way etc by simply adding the other switches into the respective ON and OFF automations.


2 way ON Automation2 way OFF Automation

How to set up vertical slider on a 5500SHAC/NAC, 5500NAC2/AC2?

Under Visualization Parameter

tick the Vertical slider and invert the vertical slider option to flip the horizontal slider to a vertical slider icon

horizontal slider to vertical slider

 

tick inversion optionTick inver vertical slider


 

Where can I find the files and how to update the firmware on my Zigbee Wiser devices when I don’t have the Wiser Hub?

Firmware for the Wiser devices is updated via the Wiser by SE app and is done via the mode of connection. If your device is connected in Bluetooth in Wiser by SE, you will have access to Bluetooth firmware updates and if your Wiser device is connected in Zigbee via the Wiser Hub to Wiser by SE, you will have access to Zigbee firmware updates.
Without the Wiser Hub you will be unable to connect Wiser devices via Zigbee in Wiser by SE and therefore will be unable to update your devices. 
We do not offer any other methods for updating firmware on the devices.
 

My Wiser battery device is showing the battery is almost flat, can I replace the battery and what do I replace it with?

All battery devices in the Wiser range have pictograms on how to change the battery in the instructions, which are available on the appropriate product page on our website (https://www.clipsal.com/products/wiser-smart-home-solutions). It also states the type of battery used for each unit. 

CLP591011/PDL591011 - Window/Door Sensor - CR2450 x 1
CLP595011/PDL595011 - Motion Sensor - LR03 AAA x 2 
CLP593011/PDL593011 - Temp/Humidity Sensor - CR2450 x 1
CLP592011/PDL592011 - Water Leakage Sensor - LR03 AAA x 2
 

What is the Standby Power of my Wiser devices?

Wiser Micro Module Switch - CLP5011WSZ/PDL5011WSZ - 0.4 W
Wiser Micro Module Dimmer - CLP5010WDZ/PDL5010WDZ - 0.4 W
Wiser Micro Module Blind - CLP5015WBZ/PDL5015WBZ - 0.4 W
Wiser Hub - CLP501902/PDL501902 - 0.2 W 
Bluetooth 2AX - 41E2PBSWM-VW/PDL356PB2MBTW-VW - 0.25 W
Bluetooth 10AX - 41E10PBSWM-VW/PDL356PB10MBTW-VW - 0.20 W
Bluetooth Dimmer - 41EPBDWCLM-VW/PDL354PBDMBTW-VW - 0.50 W
Bluetooth Socket - 3025CSG/PDL395CSG - 0.30 W
ZigBee 2AX - 41E2PBSWMZ-VW/PDL356PB2MBTZ-VW - 0.25 W
ZigBee 10AX - 41E10PBSWMZ-VW/PDL356PB10MBTZ-VW - 0.20 W
ZigBee Dimmer - 41EPBDWCLMZ-VW/PDL354PBDMBTZ-VW - 0.50 W
ZigBee Socket - 3025CSGZ/PDL395CSGZ - 0.30 W

What is the hole size of the padlock provision for a GV2P starter?

Issue:
Padlock hole diameter on GV2P

Product Line:
GV2 Manual Motor Protectors

Environment:
All GV2P, rotary handle. 

Cause:
n/a

Resolution:
There are provisions for one padlock only, the hole size is approximately 6mm.  You can add a GV2V03 padlock attachment that will allow up to 6 padlocks for Lock out Tag out applications.

My Wiser battery device is showing the battery is almost flat, but it hasn’t been 5 years?

The battery devices state Up to 5 years and that this may vary based on the default settings, usage, frequency of firmware updates and the environment its placed in. 
For example if the Temperature/Humidity sensor was placed where temperature fluctuation were happening frequently this would increase the number of reports it sends and therefore increase the battery usage when compared to one that is reporting less frequently.    
 

Video: OsiSense XC standard - How to read the complete XCMD switch references

Goals and Symptoms

OsiSense XC standard - How to read the complete XCMD switch references

Facts and Changes

XCMD universal limit switch
How to read a complete switch reference

Causes and Fixes

Attached document showing how to read a complete switch reference from the sub-assemblies indicated into the "Detection for OsiSense solutions" catalogue, in the XCMD limit switch series. On the complete XCMN switch series for OEM, the switch reference is indicated directly on the housing

Is ActiveX control required for Virtual ViewX?

Virtual ViewX is Geo SCADA Expert new web interface. It is available in Geo SCADA Expert 2019 onwards.

ActiveX control is not required for Virtual ViewX. It is designed to work on any modern browser which is HTML5 compatible.

How to download "Easergy Studio" (Micom S1 Studio)?

To download "Easergy Studio" previously known as Micom S1 Studio, Please follow the steps below:

Steps:

  1. Click the URL: http://www.schneider-electric.com/en/product-range-download/61035-easergy-studio.
  2. Go to 'Documents and Downloads' tab and then click "See More Documents" button.
  3. Scroll down to "Easergy Studio". Click 'Download' 

Easergy Studio will start to download.

Note:
You will also need to obtain the data model relevant to your Micom Relays.
For assistance regarding data models please visit the URL: http://www.schneider-electric.com.au/en/faqs/FA221295/

Why is there still 240V on the C-Bus dimmer output when it has been switched off from C-Bus?

C-Bus dimmer is controlled by Triac/Mosffet and due to this has a small leakage current.

This small leakage current will impose main voltage out on the dimmer output/load even those the channel is switched off via C-Bus.

We advise that the whole dimmer needs to be switched off before maintenance takes place.



 

What to do when C-Bus dimmer channel will not turn off ?

- Initially check that the programming is correct.

- If using LED lights, the LED may stay on when the channel is off, this is due to the leakage current being enough to power the LED, use of a 31LCDA may resolve this issue.

- If using Halogen and  the channel will not turn off, there may be damage to the electronics on this channel - Electricians only to perform this check, disconnect the Active's , Neutral and Earth from the unit, remove the cable for the load on that channel then with a multimeter check between the Neutral and that suspect channel output, if you see a low resistance the Triac has shorted.

- Advise not to use this channel and label as faulty, other channels on this dimmer should still be ok to use as per normal, alternatively you could return this unit for a quote on repair, note a repair may not be possible.

What type of LED's can be used on C-Bus Dimmers?

Firstly you will need to confirm whether your C-Bus system contains C-Bus Leading Edge Dimmers or C-Bus Universal Dimmers, You may need to consult with your EcoXpert in Light and Room Control which one(s) you have if unsure. 

The general recommendations for LED compatibility with C-Bus Dimmers is as follows
1) Ensure your LED's have a dedicated LED Driver (electronic transformer) that supports your C-Bus Dimmer type
2) Bench test that the LED Driver is of good quality and works as expected at your site
3) C-Bus Dimmer channels require >25W of load if less is connected to a specific channel that channel will require the addition of a 31LCDA (Load Corrective Device)
image.png
4) If the dimming range of the LED fittings is specified by the manufacturer - the installer can programmer the Min/Max settings of the C-Bus Dimming channel to match the LED fittings dimming range.

Note:
C-Bus Leading Edge Dimmers will require LED's which have electronic transformers (LED Driver) which support Leading Edge AC phase control dimming (as noted in the compatible loads section of the installation manual)
image.png

C-Bus Universal Dimmers will require LED's which have electronic transformers (LED Driver) which supports Trailing Edge AC phase control dimming (as noted in the compatible loads section of the installation manual).
Although Universal Dimmers can support leading OR trailing edge AC phase control dimming it needs to be exclusively one or the other (NOT BOTH). As such LED Drivers which note LE/TE LED Driver are NOT suitable for the Universal Dimmer. 
image.png
IMPORTANT: Clipsal by Schneider Electric & Schneider Electric DO NOT make LED's which are compatible with C-Bus NOR can we recommend specific LED Drivers for your C-Bus Dimmer type as LED Dimming and Driver technology is continually changing. The above is a guideline to assist you choose a compatible LED with dedicated LED Driver that supports your dimmer in question. As noted above please have your EcoXpert in Light and Room Control bench test LED Fittings and LED Driver for suitability on your C-Bus Network.  

What are the C-BUS Relay part numbers?

You have several options for relays, Catalogue numbers and information below.

L5504RVF, L5504RVFP** - 4 Channel voltage free relay - 10amps per channel
L5508RVF, L5508RVFP** - 8 Channel voltage free relay - 10amps per channel
L5512RVF, L5512RVFP** - 12 Channel voltage free relay - 10amps per channel

L5504RVF20, L5504RVF20P** - 4 Channel voltage free relay - 20amps per channel

L5508RELVP - 8 Channel Extra Low Voltage Relay

5101R - Single and Two Channel 250v AC 10amp relay
5102RVF - Single and Two Channel 250v AC 10amp Voltage Free Relay

** Any part number that has a 'P' after the part number for Din Rail mount units does NOT include a C-Bus 200ma Power Supply..