Standard Series Twin Switch Socket Outlet White Electric
Item Number: 25N-WE
Datasheet

For 25N-WE
Specifications
Design
Range of product
Product or component type
Product brand
Surface finish
Physical
Control type
Number of gangs
Pin number
Number of power socket outlets
Actuator
- switch
- rocker
Fixing mode
Local signalling
Mounting position
[ue] rated operational voltage
[in] rated current
Depth
Length
Width
Fixing center
Standards
- AS/NZS 3100
- AS/NZS 3112
- AS/NZS 3133
- AS/NZS 3000:approval number S/1
China rohs regulation
Environmental disclosure
Circularity profile
Material
Material
Documents & downloads
hide show-
All
-
Technical Data Catalogues
-
Specification Guide
-
Certificates (MSDS)
-
Declaration of Conformity
Frequently Asked Questions
hide showInrush current of the ATV61 / ATV71 High horse power VFDs.
Product Line:
ATV61HC11N4, ATV61HC31N4, ATV61HC25N4, ATV61HC40N4, ATV61HC63N4
ATV71HD90N4, ATV71HC20N4, ATV71HC25N4, ATV71HC31N4, ATV71HC50N4
Environment:
All
Cause:
Application requirement.
Resolution:
Inrush current
Drive power [kW] I peak [A] (~2ms) I peak [A] (~2ms)
Product Design Features
Product Line:
Circuit Breaker Enclosures
Resolution:
NOTE: This information will generally apply to ALL the Molded Case Circuit Breaker Enclosures(The F-frame, B-Frame, H-frame, the J-frame, the L-frame, the M-frame and P-Frame). But for the video a J250S was used.
The wiring diagram on the circuit breaker enclosures will be located on, one of the inside sidewalls of the enclosure. All the necessary information for the enclosure will be on the wiring diagram and will contain the following;
1) Catalog and series number of the enclosure
2) What type of Circuit breakers that can be used
3) Any accessory that can be used in the enclosure, like the solid neutral and equipment ground kit
4) The UL listed catalog number Prefixes for the breakers that can be used in the enclosure
5) Maximum wire sizes for the enclosure(NOTE: Sometimes the breaker can accept larger wire, BUT the enclosure wire bending space will be limited to what the wiring diagram shows)
6) The Wiring schematics
7) The Short Circuit Current Rating information for each breaker at each voltage level
8) The Date code. The date code will be an ink stamp, generally located on the inside back wall of the enclosure. The Date Code will be a 5 or 6 digit code and will read as follows; first two digits = year, the 2nd two digits = week of the year, the 5th digit = the day of the week and the last digit(if used) = the shift. For example, 183241 is year - 2018, week of year -32, day of week - 4 and shift - 1. (Aug. 9th, 2018)
DC choke dimensional size used with an ATV61HC25N4 and ATV61HC40N4.
Product line:
Altivar ATV61
Environment:
Part number specific, all serial numbers
Cause:
None
Resolution:
The DC choke used with these models is designated DC-CHOKE 3.
There are 2 units per ATV61HC25N4.
There are 3 units per ATV61HC40N4.
See the attached file for dimensional information.
Conduit kits for the Altivar Process Drives
Product Line:
Altivar Process Drive (ATV630, ATV930)
Environment:
All serial numbers for Altivar Process Drive
Cause:
N/A
Resolution:
Frame Size 1...4
- Includes IP21 conduit kit already installed on the drive
- Includes IP21 conduit kit but not installed on the drive
Conduit kits are not supplied and have to be ordered:
- Size 6 [ATV630D55M3, ATV630D75M3, ATV930D55M3C, ATV930D75M3C, ATV630C11N4, ATV630C13N4, ATV630C16N4, ATV930C11N4C, ATV930C13N4C, ATV930C16N4C]
- UL type 1 and IP21: VW3A9704
- Size 7A [ATV630C22N4, ATV930C22N4(C)]
- UL type 1: VW3A9212
- UL type 21: VW3A9112
- Size 7B [ATV630C25N4, ATV630C31N4, ATV930C25N4C, ATV930C31N4C]
- UL type 1 without braking unit: VW3A9213
- UL type 1 with braking unit: VW3A9214
- UL type 21 without braking unit: VW3A9113
- UL type 21 with braking unit: VW3A9114
Issue:
What would cause an EPF2 fault on the ATV61 drive with an Ethernet IP card?
Product Line:
Altivar ATV61
Environment:
All
Cause:
Using an Allen Bradley PLC trying to access assemblies 103 and 104, and the drive has not been set up per case 2 example as recommended in the Ethernet IP VW3A3316 manual.
Resolution:
Case 2 programming example is as follows:
- Menu 1.6
- Ref 1= Communications card
- Profile= Separate controls
- CMD switching= C312
- CMD channel 1= Communication card
- CMD channel 2= Terminal control
- Ref 2 Switching= C313
- Ref 2 Channel= AI1 or AI2