Standard Series, Single Switch Socket Outlet, 250V, 10A, Standard Size, Vertical

Standard Series, Single Switch Socket Outlet, 250V, 10A, Standard Size, Vertical White Electric

Item Number: 15V-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product or component type

switched socket

Product brand

Clipsal

Surface finish

glossy

Physical

Control type

ON/OFF button

Number of gangs

1 gang

Pin number

3

Number of power socket outlets

1

Actuator

rocker|switch

Fixing mode

by screws

Local signalling

without light indicator

Mounting position

vertical

[ue] rated operational voltage

250 V AC

[in] rated current

10 A

Depth

14 mm

Length

115 mm

Width

73 mm

Fixing center

84 mm

Standards

AS/NZS 3100|AS/NZS 3112|AS/NZS 3133|AS/NZS 3000:approval number S/1

Eu rohs directive

Compliant with Exemptions

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP120506EN

Circularity profile

N/A

Material

Material

PC (polycarbonate)

Others

Commercial status history

SESA301466 | Thu Aug 10 18:38:00 EDT 2023 | From Import Local | From 18 to 19

Package 1 bare product quantity

1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3 cm

Package 1 width

7.2 cm

Package 1 length

11.5 cm

Package 1 weight

70.4 g

Unit type of package 2

BB1

Number of units in package 2

5

Package 2 height

11.7 cm

Package 2 width

10.2 cm

Package 2 length

13.8 cm

Package 2 weight

450 g

Unit type of package 3

CAR

Number of units in package 3

100

Package 3 height

25.4 cm

Package 3 width

34.8 cm

Package 3 length

44.5 cm

Package 3 weight

9 kg
Show all specifications

Documents & downloads

hide show

Frequently Asked Questions

hide show

Does 5041NMML/5041NMS come with a push button assembly Blank?

 

5041NMML/5041NMS - doesn’t come with a push button assembly Blank
1

 

25041NMML Clipsal 40 Series C-Bus Master Module

 

 

35041NMS-Clipsal C-Bus 40 SERIES Slave Push Button Mech

 

 

5041NMS does not  come with a push button cap,  need to purchase separately

 

 

440APB(Standard PushButton)

 5 S40APB(style color range)  or
 6E40APB (essence style range)- for marking then it will be a special order

 
 

Is it possible to use ATS480 / ATS48 output side with step up transformer for 1000Vac Motor ( stepping up from 415V to 1000V ) ?

It is not recommended to use step-up transformer on ATS48/ATS480 output.

Instead of ATS, the suggestion is to use VSD + Sinus filter + step up transformer combination for this requirement.


The dv/dt output voltage of the ATS48/ATS480 will be the cause of current and voltage oscillations and overvoltages.

Thyristors can burn in overvoltage and the insulation of the motor has to be high enough.

The magnetic saturation of the transformer will cause overcurrents which will damage the thyristors.

In case of micro cut of the main supply, overcurrent will appear.

 

What is a 3 phase 20 amp RCBO made up of?

The part number for a 3 phase, 20Amp RCBO is a 4RCBE420/30.

Specifications
Supply Voltage415 V AC
Rating20A
Fault Current6000A
Sensitivity30mA
Poles3P+N
TypeType A
Pole Width5 Modules (18mm × 5)
Curve TypeC - Curve
Top or Bottom FedBoth
IP RatingIP20
MountDin-Rail (Double Locking Clip)
IndicatorPositive Contact and Red Flag
CertificationApproval to AS/ NZS 61009.1:2015

For further information please visit https://www.clipsal.com/products/detail?catno=4RCBE420/30&tab-document-1=0

Max4 RCBO 3PN C 20A 6000A 30mA A type 415V RCBO
 

Can I use the 2P iC60 (N or H) MCB for 400V application (e.g. measuring 400V across phase to Neutral)?

Issue:

Can use the 2P iC60 (N or H) MCB for 400V application measuring 400V across phase to Neutral?

Product Line:

Acti 9

Environment:

iC60 (N or H)

Resolution:

Yes, MCBs Acti9 iC60N/H 2P can be used under Ue (Ph/N) or (Ph/Ph)=400Vac applications.
You can refer to breaking capacities declared in catalogue pages for Ue=380-415Vac (e.g Icu=10kA for iC60N 2P C 40A including ref.A9F44240).

What is the replacement for NS630H with STR23SE trip unit?

The alternative replacement for NS630H with STR23SE trip unit is the new offer Compact NSX new Generation C63H32D630.


C63H32D630

Circuit breaker, ComPacT NSX630H, 70kA/415VAC, 3 poles, MicroLogic 2.3 trip unit 630A

What does the Y mean at the end of the ATS48 part number?

Issue:
N/A

Product Line:
Altistar 48

Environment:
Altistart 48

Cause:
N/A

Resolution:
ATS48 has a control supply and a power supply.

On  the Y range, you have a control supply that is 110-220 and the power supply is 208-690V. Y range is dedicated for the US market, with NEC standard soft starter that must be protected against the current unbalance.  Y range has three current sensors,. There are only 2 on the Q range (one more OLF on the Y range).

On Q range, the control supply is 220-415V and the power supply is 230-415V.
 

What are the default settings of Dip Switch in UA Controller?

The default settings of UA controller for automatic transfer of circuit breaker is listed in the table. 
 
Dip Switch settings
Dip Switch240VAC415VAC
A01
B11
C00

Dip switch A is Voltage dependent. 
image.png
Refer to user manual for further information - https://www.se.com/au/en/download/document/51201113AA/

What is the replacement for CA2DN31E7?

The replacement for CA2DN31E7 is CAD32E7

CAD32E7 has 48V AC coil.

Other coil voltages are :

AC = 24V-B7, 32V-C7, 48V-E7, 110V-F7, 220-M7, 240V-U7, 415V-N7

DC = 12V-JD, 24V-BD, 48V-ED, 110V-FD, 220V-MD

 

What is the difference between the iC60N and the iC60H Circuit Breakers?

The differences between the iC60N and iC60H series of circuit breakers is the iC60N has a breaking capacity of 6kA at 240/415V, C Curve in accordance with AS/NZS60898.1, where as the iC60H has a breaking capacity of 10kA at 240/415V B, C & D Curve in accordance with AS/NZS60898.1.

In Australia the iC60N is only available in C Curve where as the iC60H is available in B, C & D Curve.
 
iC60N & iC60H Dimensions

Connection: Tunnel terminals for the following cables
- up to 25A : 25mm2 stranded
- 32 to 63A : 35mm2 stranded

For further information please visit https://www.schneider-electric.com.au/en/product-subcategory/1605-acti-9-miniature-circuit-breakers---mcbs/


 

What are the 9013FHG pressure switch contacts rated at?

Issue:
Contact Rating of 9013F Pressure Switches

Product Line: 
Pressure, vacuum and Float Switches 

Environment:
9013 Type F Pressure Switch 

Resolution:
Those contacts have a control circuit rating of A600.
They are DC rated at 1/4 HP at 115V and 230V (Except form M4)
They are Single Phase AC rated 1 1/2 HP at 115V, 2 HP at 230V
They are Polyphase rated 2 HP at 115V, 3 HP at 230V, and 1 HP at 460/575V.

This also applies to the 9013 FHG2, 9, 12, 13, 44, 49 9013 FSG, and FSW.

What is the DC Bus Voltage Threshold at which the Brake IGBT operates in Altivar 71 Drive powered with 220VAC or 415VAC 3 Phase.

The Altivar 71 Drive Braking IGBT operates when the value of DC Bus Voltage is higher than the DC Bus Threshold Voltage OBR. When the value of the DC Bus Voltage is lower than the threshold voltage (Unom_max + 10%), the Braking IGBT/Transistor is switched off.

The Voltage Threshold Values for a Drive working on 220VAC or 415VAC, 3Phase is provided in the attachment.

Note:

OBR is the threshold point where the Braking Transistor switches ON and Unom_max + 10% is the threshold point where the Braking Transistor switches OFF.

What Earth leakage protection relay do I require?

Firstly Choose from the two types of relays, (DIN rail mount or Front-panel mount) Using the tables below.
Then make a selection dependent on the voltage required along with the settings desired.


Vigirex Earth Leakage Protection Relay (DIN rail mount)
TYPEPOWER SUPPLYSETTINGSREFERENCE
RH21M12 to 24V AC- 12 to 48V DC30mA-Inst, 300mA-Insta or 300mA-60ms56160
 48V AC30mA-Inst, 300mA-Insta or 300mA-60ms56161
 110 to 130V AC30mA-Inst, 300mA-Insta or 300mA-60ms56162
 220 to 240V AC30mA-Inst, 300mA-Insta or 300mA-60ms56163
 380 to 415V AC30mA-Inst, 300mA-Insta or 300mA-60ms56164
 440 to 525VAC30mA-Inst, 300mA-Insta or 300mA-60ms56165
RH99M12 to 24V AC- 12 to 48V DC30mA to 30A- Inst to 4.5s56170
 48V AC30mA to 30A- Inst to 4.5s56171
 110 to 130V AC30mA to 30A- Inst to 4.5s56172
 220 to 240V AC30mA to 30A- Inst to 4.5s56173
 380 to 415V AC30mA to 30A- Inst to 4.5s56174
 440 to 525V ac30mA to 30A- Inst to 4.5s56175




Vigirex Earth Leakage Protection Relay (Front-Panel mount)
TYPEPOWER SUPPLYSETTINGSREFERENCE
RH21P12 to 24V AC- 12 to 48V DC30mA-Inst, 300mA-Insta or 300mA-60ms56260
 48V AC30mA-Inst, 300mA-Insta or 300mA-60ms56261
 110 to 130V AC30mA-Inst, 300mA-Insta or 300mA-60ms56262
 220 to 240V AC30mA-Inst, 300mA-Insta or 300mA-60ms56263
 380 to 415V AC30mA-Inst, 300mA-Insta or 300mA-60ms56264
 440 to 525VAC30mA-Inst, 300mA-Insta or 300mA-60ms56265
RH99P12 to 24V AC- 12 to 48V DC30mA to 30A- Inst to 4.5s56270
 48V AC30mA to 30A- Inst to 4.5s56271
 110 to 130V AC30mA to 30A- Inst to 4.5s56272
 220 to 240V AC30mA to 30A- Inst to 4.5s56273
 380 to 415V AC30mA to 30A- Inst to 4.5s56274
 440 to 525V ac30mA to 30A- Inst to 4.5s56275
RHU220 to 240V AC15mA to 30A- Inst to 5s28560(1)

Then choose a Toroidal to suit:
Vigirex Sensors (Toroidal and rectangular)
TYPEDESCRIPTIONDIMENSIONRATED OPERATIONAL CURRENTREFERENCE
Closed Toroid,A-typeTA3030mm65A50437(2)
 PA4050mm85A50438(2)
 IA8080mm160A50439
 MA120120mm250A50440
 SA200200mm400A50441
 GA300300mm630A50442
Split Toroid, OA-typePOA46mm85A50485
 GOA110mm250A50486
Rectangular SensorsSmall Rectangular Sensors280 x 115mm1600A56053(3)
 Large Rectangular Sensors470 x 160mm3200A56054(3)

For further information please visit https://www.se.com/au/en/product-range/1014-vigirex/?parent-subcategory-id=4250
Earth-leakage relay RH10M - 1 A - 24 VEarth-leakage relay RH10P - 30 mA - 24 V



 

What are the codes of the items supplied with the 3 phase EV parking protection kits?

Parts that should be supplied as follows:

KITPARKING22-1:
A9F54440 x 1, MCB, iC60H 4P 40A C Curve
A9Z51440 x 1, RCD, iIDP 4P 40A 30mA Type B, 400V
A9A26969 x 2, Under voltage release, iMNX 220 240VAC
A9F44204 x 1, MCB, iC60N 2P 4A C Curve
A9R91240 x 1, RCCB, iID 2P 40A 30mA Type Asi
A9A26924 x 2, Aux contact, iOF 240 415VAC 24 130VDC

KITPARKING22-2:
A9F54440 x 2, MCB, iC60H 4P 40A C Curve
A9Z51440 x 2, RCD, iIDP 4P 40A 30mA Type B, 400V
A9A26969 x 3, Under voltage release, iMNX 220 240VAC
A9F44204 x 1, MCB, iC60N 2P 4A C Curve
A9R91240 x 1, RCCB, iID 2P 40A 30mA Type Asi
A9A26924 x 4, Aux contact, iOF 240 415VAC 24 130VDC
 

Why can't I use a domestic model APC UPS on a ship

Issue:

In North America, one would expect to see approximately 120 volts when
measuring from hot to neutral and from hot to ground. However, large ships
use delta power. That is, there are two hot legs (center tapped 120Vac) and a
ground: no neutral. Each hot is 60 volts. One can measure from hot to hot
(phase to phase) and will see 120 volts. When measuring from either hot to
ground, one will see 60 volts.


Product Line:

Smart-UPS

Environment:

All models with the "X93" suffix (IE: SU700X93, SUA1500X93)

Cause:

Standard North American Smart-UPS are designed for a 3 wire input comprised of a 120v Hot, Neutral, and Ground.


Resolution:

For this environment, APC has the Smart-UPS X93 Shipboard Series. A standard
120Vac model should not be used on a ship with delta power. When a 120Vac
APC UPS transfers to battery, it supplies 115V +/-5V on the hot leg. Herein
lies the problem with standard models on ships. According to the National
Electric Code, the neutral leg must be passed through the standard UPS
units without interruption. As a result, it is possible that 180Vrms may be
passed to the load when switching to battery (120Vac from the UPS inverter on
one phase and 60 volts from the ship on the second phase). Most computers have
power supplies that accept a wide range of input voltage; therefore, they would
not be affected by the voltage jump. However, if the load has any common mode
suppression (i.e. 150Vac MOVs), then the load may be affected.



Input to the X93 units is two hot legs at 60Vac each. The output is one hot
120Vac leg, a neutral and a ground. The primary differences between the X93
unit and the domestic are that the site wiring fault circuit is disabled, a
double pole breaker replaces the single pole breaker at the input, and a triple
pole switch is added that can disconnect the incoming AC as well as the bias
supplies in the UPS (it won't turn on anymore). The X93 does not break both
line and neutral unless the input breaker is tripped. If it just goes to
battery, the output and input neutral are still continuous. The ground and
neutral are not connected by the UPS so unless the neutral is bonded to ground
on the ship at the supply or load, one will not necessarily measure 0 volts from
neutral to ground at the output of the UPS.



Note: A customer who has decided to use a domestic model on a ship producing
delta power aware that  the ship must have over current protection (fuse or circuit breaker)
in each hot leg. This is because a fault within the UPS (highly unlikely) from neutral
(whichever hot leg corresponds to the neutral) to ground is not protected by
the UPS's circuit breaker. Without this branch protection on the ship, such a
fault within the UPS could be dangerous because fault current is not limited.

What is the replacement model for a NS100N 3 Pole molded case circuit breaker?

The replacement model for a NS100N 3 Pole is the NSX100F 3P range.

NSX100F: (36kA at 415V)
Complete/3 Pole Front Connected
DescriptionTypeTrip UnitRatingPart Number
NSX100F (36kA) Distribution ProtectionStandard thermal-magnetic trip unit TM-DTM16D11-16ALV429637
TM25D17-25ALV429636
TM32D22-32ALV429635
TM40D28-40ALV429634
TM50D35-50ALV429633
TM63D44-63ALV429632
TM80D56-80ALV429631
TM100D70-100ALV429630
Electronic Trip unit Micrologic 2.2 (LSol)40A18-40ALV429772
100A40-100LV429770
Electronic Trip unit Micrologic 5.2A (LSI) (ammeter)40A18-40ALV429882
100A40-100LV429880
NSX100F (36kA)
Motor Protection
Nagnetic only trip Unit MAMA2.52.5A, 0.75kWLV429745
MA6.36.3A, 2.2kWLV429744
MA12.512.5A, 5.5kWLV429743
MA2525A, 11kWLV429742
MA5050A, 22kWLV429741
MA100100A, 45kWLV429740
Electronic Trip unit Micrologic 2.2 (LSol)25A12-25A, 11kWLV429828
50A25-50A, 22kWLV429827
100A50- 100A, 45kWLV429825



There is also a 4P model as well.

Please see link to Product guide - http://www2.schneider-electric.com/resources/sites/SCHNEIDER_ELECTRIC/content/live/FAQS/297000/FA297893/pl_PL/CROSSFER%20NS%20TO%20NSX.pdf
 

What versions of XRG come with Vigilohm mobile fault locating kit?

There are 3 versions of XRG: 
- 115/127V AC (Reference Number - 50281)
- 220/240V AC (Reference Number - 50282)
- 380/415V AC (Reference Number - 50283). 

The high voltage version could be used in lower voltage network. 

For example, the 50283 could be used in network which has L-N voltage 115. 

However, the low voltage version could not be used in high voltage network.