Standard Series Single Socket Outlet White Electric
Item Number: 402-WE
Datasheet

For 402-WE
Specifications
Design
Product or component type
Product brand
Physical
Quantity per set
Marking
Local signalling
Device mounting
Fixing mode
[in] rated current
[ue] rated operational voltage
Depth
Fixing center
Number of poles
Standards
- AS/NZS 3100
- AS/NZS 3112
- AS/NZS 3133
- AS/NZS 3000:approval number S/1
Reach regulation
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Product Brochures
-
Technical Data Catalogues
-
Installation Instruction
-
Specification Guide
-
Certificates (MSDS)
Frequently Asked Questions
hide showOn the Altivar drives, in CiA402 profile, what sequence is written to run drive in Reverse?
Product LIne:
Altivar drives with serial communication control in CiA-402 (Drivecom) Mode of operation.
Environment:
All current production models with the exception of the ATV212 series, all serial numbers
Cause:
To issue a run command forward in CiA402 profile, you must write the sequence 6,7,15 to the command word. What sequence should be written to run reverse?
Resolution:
In order to run, Bits 0-3 must be all high, this translates to decimal value of 15. Bit 11 of the control word determines the direction of the the drive. When bits 0,1,2,3 are high (decimal 15) the drive runs in Forward direction. When bits 0,1,2,3,11 are high (decimal 2063) the drive runs in Reverse direction.
Please go to the following links below and check under the Documentation Tab for more information.
Australia - https://www.clipsal.com/products/detail?CatNo=Z4025&itemno=Z4025-ZW&backto=/search?q=Z4025&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=Z4025&itemno=Z4025-ZW&backto=/search?q=Z4025&tab-document-1=0
3) Verify XW CHARGE CYCLE is '2Stg/NoFloat' in XW Advanced - Charger Settings - Charge Cycle (factory default setting)
4) On MPPT set CHARGE CYCLE to '3 stage' in MPPT Advanced - Charger Settings - Charge Cycle
5) It is also recommended that the system has a minimum battery capacity of 200Ah. An additional 100Ah for every 1kW of solar power is preferable.
Note: There may be times where the fan needs to be replaced and customer would like to know the ratings of the fan. Physically, the fan's size is 12cm by 12cm.
Caution: This should only be done safely and by a qualified technician
From the System Status Screen
1.) Press Enter
2.) Under Select Device select the SCP
3.) Scroll down until you see Fault Alarm
4.) Press enter to enable/disable
*NOTE: Below the fault alarm option there is an additional low battery alarm that you would need to enable separately from the fault alarm option