Standard Series, Flush Switch, 2 Gang, 250VAC, 10A, Architrave White Electric
Item Number: 32A-WE
Datasheet
Specifications
Design
Range of product
Product brand
Sustainable offer status
Physical
Device presentation
Number of poles
Device mounting
Number of rocker
Local signalling
[ue] rated operational voltage
Rated current
Marking
Fixing mode
Actuator
Switch function
Reach regulation
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
Others
Package 1 bare product quantity
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Documents & downloads
hide show-
All
-
Technical Data Catalogues
-
Environmental Disclosure
-
Certificates (MSDS)
Frequently Asked Questions
hide showRCBO | |||
Material | Alternative Material | Description | Comment |
QOE110BO3 | QO110B10RCBO30F | QOE RCBO 1P+N 10A B 30mA 10kA | Direct Replacement |
QOE116BO3 | QO116B10RCBO30F | QOE RCBO 1P+N 16A B 30mA 10kA | Direct Replacement |
QOE120BO3 | QO120B10RCBO30F | QOE RCBO 1P+N 20A B 30mA 10kA | Direct Replacement |
QOE132BO3 | QO132B10RCBO30F | QOE RCBO 1P+N 32A B 30mA 10kA | Direct Replacement |
QOE140BO3 | QO140B10RCBO30F | QOE RCBO 1P+N 40A B 30mA 10kA | Direct Replacement |
Part number for the replacement of the ATS01N High HP Soft Starters.
Product line:
ATS01, Altistart 01, High HP
Environment:
All models
Cause:
The launch of the ATS22 in 2011 caused the High HP units to become redundant.
Resolution:
The ATS01 High HP units were replaced with the ATS22 units. These are functional replacements only. The ATS01 had no overload protection, an internal power supply and simple dial adjustments. The ATS22 will require external 120V or 230V power. There are no dials to adjust, but the unit will need to be programmed. See the ATS22 User Manual, document BBV51330 to review the wiring, dimensions and programming. See the attached file.
ATS01N230LY - 32A rated. Replaced by ATS22D32S6U
ATS01N244LY - 44A rated. Replaced by ATS22D47S6U
ATS01N272LY - 72A rated. Replaced by ATS22D75S6U
ATS01N285LY - 85A rated. Replaced by ATS22D88S6U
Contacts need to be replaced in a CAD32** relay.
Product Line:
TeSys D IEC style relays
Environment:
CAD relays
Resolution:
The TeSys D IEC style relays do not offer replacement contacts.
Operating temperature range for the Altistart 22
Product Line:
ATS22, Altistart 22
Environment:
All models, all serial numbers.
Cause:
high or low ambient temperatures.
Resolution:
The standard current ratings for the ATS22 is based on an ambient temperature of 40C (104F).
The minimum operating temperature is -10C (14F). The maximum operating temperature is 60C (140F).
When operating above 40C (104F), the softstart needs to be derated by 2.2% for every degree Celsius above 40C (104F).
For example: ATS22D32S6U is 32A rated. For an ambient temperature of 50C (122F), derating is 22% (2.2 x 10). The 32A softstart rating becomes 24.96A (32A x 0.78 = 24.96).
No, the breaker is Polarized and can only be Fed from Bottom
It will be the same for all iC0H DC single pole breakers:
C60H-DC Rating (In) Reference C curve 1P
1A A9N61501
2A A9N61502
4A A9N61504
6A A9N61506
10A A9N61508
16A A9N61511
20A A9N61512
25A A9N61513
32A A9N61515
40A A9N61517
50A A9N61518
63A A9N61519
Material | Description | Comment | Direct Replacement |
QO106EC10 | MINIATURE CIRCUIT BREAKER 240V 6A | Discontinued | no replacement |
QO110EC10 | QOvs 1P 10A 10kA Type C | Direct Replacement | QO110VSC10 |
QO116EC10 | QOvs 1P 16A 10kA Type C | Direct Replacement | QO116VSC10 |
QO120EC10 | QOvs 1P 20A 10kA Type C | Direct Replacement | QO120VSC10 |
QO125EC10 | QOvs 1P 25A 10kA Type C | Direct Replacement | QO125VSC10 |
QO132EC10 | QOvs 1P 32A 10kA Type C | Direct Replacement | QO132VSC10 |
QO140EC10 | QOvs 1P 40A 10kA Type C | Direct Replacement | QO140VSC10 |
QO150EC10 | QOvs 1P 50A 10kA Type C | Direct Replacement | QO150VSC10 |
QO163EC10 | QOvs 1P 63A 10kA Type C | Direct Replacement | QO163VSC10 |
QOH180XAUS | MCB QOH 1P 80A 6KA | Discontinued | no replacement |
QOH1100XAUS | MCB QOH 1P 100A 6KA | Discontinued | no replacement |
QO310EC10 | QOvs 3P 10A 10kA Type C | Direct Replacement | QO310VSC10 |
QO316EC10 | QOvs 3P 16A 10kA Type C | Direct Replacement | QO316VSC10 |
QO320EC10 | QOvs 3P 20A 10kA Type C | Direct Replacement | QO320VSC10 |
QO325EC10 | QOvs 3P 25A 10kA Type C | Direct Replacement | QO325VSC10 |
QO332EC10 | QOvs 3P 32A 10kA Type C | Direct Replacement | QO332VSC10 |
QO340EC10 | QOvs 3P 40A 10kA Type C | Direct Replacement | QO340VSC10 |
QO350EC10 | QOvs 3P 50A 10kA Type C | Direct Replacement | QO350VSC10 |
QO363EC10 | QOvs 3P 63A 10kA Type C | Direct Replacement | QO363VSC10 |
QOH380XAUS | MCB QOH 3P 80A 6KA | Discontinued | no replacement |
RCBO | |||
QOE110BO3 | QOE RCBO 1P+N 10A B 30mA 10kA | Direct Replacement | QO110B10RCBO30F |
QOE116BO3 | QOE RCBO 1P+N 16A B 30mA 10kA | Direct Replacement | QO116B10RCBO30F |
QOE120BO3 | QOE RCBO 1P+N 20A B 30mA 10kA | Direct Replacement | QO120B10RCBO30F |
QOE132BO3 | QOE RCBO 1P+N 32A B 30mA 10kA | Direct Replacement | QO132B10RCBO30F |
QOE140BO3 | QOE RCBO 1P+N 40A B 30mA 10kA | Direct Replacement | QO140B10RCBO30F |
You can use 3 Pole 32 Amps iC60 MCB and connect it with the 3 Pole Add-on Vigi Module "A9V02763" (comes with the neutral tail to be connected with the distributed neutral) - this combination is 6 Poles wide
If balanced three phase system with out neutral you should use Add on Vigi "A9V51363" - this combination is 6½ Pole wide
The difference is the ISO Standard that the product is manufactured to comply with:
- IEC/EN 60669
- IEC/EN 60947-3
For 40-125A they comply with IEC/EN 60947-3
The operating temperature of I range switches is:-
- For IEC/EN 60669 devices between - 20°C...+50°C without derating.
- For IEC/EN 60947-3 devices -25...+60 °C without derating.
Their storage temperature must be:-
- For IEC/EN 60669 devices between - 40...+100°C
- For IEC/EN 60947-3 devices between -40...+85 °C
Single phase = A9Z51240 + A9F54232
3 phase = A9Z51440 + A9F54432
Replacement NetShelter key or additional matching keys are needed.
Product Line:
NetShelter Cabinets, EcoAisle
Environment:
All versions and serial ranges.
Cause:
Keys may be lost, or spares may be required.
Resolution:
This document explains which keys are used for various NetShelter cabinets and how to obtain them.
NetShelter SX, SV, AV & VX:
Please use Part W870-8135 as the replacement key for NetShelter SX, AV and VX front & rear door handles and side panels. This is a single key, not a pair. It’s a sellable part. It can also be RMA’d for in-warrantee replacement. We allow customers one extra key per cabinet as in-warrantee replacement during the first year of ownership. If you need an in-warrantee replacement please call APC customer service and have the cabinet's model number and serial number available.
NetShelter WX:
AR100 and AR100 HD please use Part 840-0103 as the replacement key & door handle kit.
AR106, AR109 and AR112 please use W870-8135.
NetShelter CX:
Please use Part 0H-0292-SE as the replacement keys for all NetShelter CX door locks. This is a set of two (2) keys.
AR8132A Combination Lock Handles:
We do not currently stock a replacement key for the AR8132A combination lock handle. If you need to order a replacement key it must be ordered direct from the manufacturer, EMKA. or one of their distributors. The EMKA part number is 1108-U36-222. See below for EMKA contact information.
EcoAisle:
Key for drop out panels: W870-8135.
Key for the sliding door: 0J-870-26645.
EMKA contact information:
United States Headquarters: EMKA Inc.1961 Fulling Mill Road Middletown, PA 17057 Phone: 717-986-1111
European Headquarters: EMKA Beschlagteile GmbH & Co. KGLangenberger Str. 32D-42551 Velbert (Germany)Phone: +49 (0)2051 273-0
For specific regional contacts, please reference EMKA’s website. www.emka.com
2) Less than 100W of consumption when the CT is closed. We are just a gate between the grid and the car.
So the maximum consumption is 100w (dedicated to 24v power supply, motherboard, contactor and led). Efficiency will be,
If the load is a 3,7kW (16A 1P) efficiency = 97%
If the load is a 22kW (32A 3P) efficiency = 99,5%
But, also consider the Harmonics, Power factor produced by the Car itself which will affect efficiency.
NSX100F: (36kA at 415V)
Complete/3 Pole Front Connected
Description | Type | Trip Unit | Rating | Part Number |
NSX100F (36kA) Distribution Protection | Standard thermal-magnetic trip unit TM-D | TM16D | 11-16A | LV429637 |
TM25D | 17-25A | LV429636 | ||
TM32D | 22-32A | LV429635 | ||
TM40D | 28-40A | LV429634 | ||
TM50D | 35-50A | LV429633 | ||
TM63D | 44-63A | LV429632 | ||
TM80D | 56-80A | LV429631 | ||
TM100D | 70-100A | LV429630 | ||
Electronic Trip unit Micrologic 2.2 (LSol) | 40A | 18-40A | LV429772 | |
100A | 40-100 | LV429770 | ||
Electronic Trip unit Micrologic 5.2A (LSI) (ammeter) | 40A | 18-40A | LV429882 | |
100A | 40-100 | LV429880 | ||
NSX100F (36kA) Motor Protection | Nagnetic only trip Unit MA | MA2.5 | 2.5A, 0.75kW | LV429745 |
MA6.3 | 6.3A, 2.2kW | LV429744 | ||
MA12.5 | 12.5A, 5.5kW | LV429743 | ||
MA25 | 25A, 11kW | LV429742 | ||
MA50 | 50A, 22kW | LV429741 | ||
MA100 | 100A, 45kW | LV429740 | ||
Electronic Trip unit Micrologic 2.2 (LSol) | 25A | 12-25A, 11kW | LV429828 | |
50A | 25-50A, 22kW | LV429827 | ||
100A | 50- 100A, 45kW | LV429825 |
There is also a 4P model as well.
Please see link to Product guide - http://www2.schneider-electric.com/resources/sites/SCHNEIDER_ELECTRIC/content/live/FAQS/297000/FA297893/pl_PL/CROSSFER%20NS%20TO%20NSX.pdf