Standard Series, Flush Switch, 2 Gang, 250VAC, 10A, Architrave

Standard Series, Flush Switch, 2 Gang, 250VAC, 10A, Architrave White Electric

Item Number: 32A-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Device presentation

basic element with full cover plate and grid

Number of poles

1

Device mounting

flush

Number of rocker

2

Local signalling

without

[ue] rated operational voltage

250 V AC

Rated current

10 A

Marking

without marking

Fixing mode

by screws

Actuator

rocker

Switch function

1-pole

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP120506EN

Circularity profile

N/A

Others

Package 1 bare product quantity

1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

2.9 cm

Package 1 width

3.28 cm

Package 1 length

8.62 cm

Package 1 weight

44 g
Show all specifications

Frequently Asked Questions

hide show

What are the replacement part numbers for a Square D RCBOs example QOE120B03?

Please see attached document for the characteristics of the new RCBos and below table shows the replacement part#s
RCBO   
MaterialAlternative MaterialDescriptionComment
QOE110BO3QO110B10RCBO30FQOE RCBO 1P+N 10A B 30mA 10kADirect Replacement
QOE116BO3QO116B10RCBO30FQOE RCBO 1P+N 16A B 30mA 10kADirect Replacement
QOE120BO3QO120B10RCBO30FQOE RCBO 1P+N 20A B 30mA 10kADirect Replacement
QOE132BO3QO132B10RCBO30FQOE RCBO 1P+N 32A B 30mA 10kADirect Replacement
QOE140BO3QO140B10RCBO30FQOE RCBO 1P+N 40A B 30mA 10kADirect Replacement
    


 

What is the replacement for the High HP ATS01N softstarters?

Issue:
Part number for the replacement of the ATS01N High HP Soft Starters.

Product line:
ATS01, Altistart 01, High HP

Environment:
All models

Cause:
The launch of the ATS22 in 2011 caused the High HP units to become redundant.

Resolution:

The ATS01 High HP units were replaced with the ATS22 units.  These are functional replacements only.  The ATS01 had no overload protection, an internal power supply and simple dial adjustments.  The ATS22 will require external 120V or 230V power.  There are no dials to adjust, but the unit will need to be programmed.  See the ATS22 User Manual, document BBV51330 to review the wiring, dimensions and programming.  See the attached file.

ATS01N230LY - 32A rated.  Replaced by ATS22D32S6U
ATS01N244LY - 44A rated.  Replaced by ATS22D47S6U
ATS01N272LY - 72A rated.  Replaced by ATS22D75S6U
ATS01N285LY - 85A rated.  Replaced by ATS22D88S6U

 

Are replacement contacts available for a CAD32 relay?

Issue:
Contacts need to be replaced in a CAD32** relay.

Product Line:
TeSys D IEC style relays

Environment:
CAD relays

Resolution:
The TeSys D IEC style relays do not offer replacement contacts.

Can the ATS22 operate at 50 deg C temperatures?

Issue:
Operating temperature range for the Altistart 22

Product Line:
ATS22, Altistart 22

Environment:
All models, all serial numbers.

Cause:
high or low ambient temperatures.

Resolution:
The standard current ratings for the ATS22 is based on an ambient temperature of 40C (104F).  

The minimum operating temperature is -10C (14F).  The maximum operating temperature is 60C (140F).
When operating above 40C (104F), the softstart needs to be derated by 2.2% for every degree Celsius above 40C (104F).

For example:  ATS22D32S6U is 32A rated.  For an ambient temperature of 50C (122F), derating is 22% (2.2 x 10).  The 32A softstart rating becomes 24.96A (32A x 0.78 = 24.96). 

Can A9N61512 iC60H DC breaker be fed from top

No, the breaker is Polarized and can only be Fed from Bottom
image.pngimage.png
It will be the same for all iC0H DC single pole breakers:
C60H-DC Rating (In) Reference C curve 1P
1A A9N61501
2A A9N61502
4A A9N61504
6A A9N61506
10A A9N61508  
16A A9N61511
20A A9N61512
25A A9N61513
32A A9N61515
40A A9N61517
50A A9N61518
63A A9N61519

 

What are the ranges of the Square D Circuit Breakers?

MaterialDescriptionCommentDirect Replacement
QO106EC10MINIATURE CIRCUIT BREAKER 240V 6ADiscontinuedno replacement
QO110EC10QOvs 1P 10A 10kA Type CDirect ReplacementQO110VSC10
QO116EC10QOvs 1P 16A 10kA Type CDirect ReplacementQO116VSC10
QO120EC10QOvs 1P 20A 10kA Type CDirect ReplacementQO120VSC10
QO125EC10QOvs 1P 25A 10kA Type CDirect ReplacementQO125VSC10
QO132EC10QOvs 1P 32A 10kA Type CDirect ReplacementQO132VSC10
QO140EC10QOvs 1P 40A 10kA Type CDirect ReplacementQO140VSC10
QO150EC10QOvs 1P 50A 10kA Type CDirect ReplacementQO150VSC10
QO163EC10QOvs 1P 63A 10kA Type CDirect ReplacementQO163VSC10
QOH180XAUSMCB QOH 1P 80A 6KADiscontinuedno replacement
QOH1100XAUSMCB QOH 1P 100A 6KADiscontinuedno replacement
QO310EC10QOvs 3P 10A 10kA Type CDirect ReplacementQO310VSC10
QO316EC10QOvs 3P 16A 10kA Type CDirect ReplacementQO316VSC10
QO320EC10QOvs 3P 20A 10kA Type CDirect ReplacementQO320VSC10
QO325EC10QOvs 3P 25A 10kA Type CDirect ReplacementQO325VSC10
QO332EC10QOvs 3P 32A 10kA Type CDirect ReplacementQO332VSC10
QO340EC10QOvs 3P 40A 10kA Type CDirect ReplacementQO340VSC10
QO350EC10QOvs 3P 50A 10kA Type CDirect ReplacementQO350VSC10
QO363EC10QOvs 3P 63A 10kA Type CDirect ReplacementQO363VSC10
QOH380XAUSMCB QOH 3P 80A 6KADiscontinuedno replacement
    
RCBO   
QOE110BO3QOE RCBO 1P+N 10A B 30mA 10kADirect ReplacementQO110B10RCBO30F
QOE116BO3QOE RCBO 1P+N 16A B 30mA 10kADirect ReplacementQO116B10RCBO30F
QOE120BO3QOE RCBO 1P+N 20A B 30mA 10kADirect ReplacementQO120B10RCBO30F
QOE132BO3QOE RCBO 1P+N 32A B 30mA 10kADirect ReplacementQO132B10RCBO30F
QOE140BO3QOE RCBO 1P+N 40A B 30mA 10kADirect ReplacementQO140B10RCBO30F

What is the part code for a 3 Phase 32A 30mA RCBO?

We do not offer a single 3 Pole 32 Amps 30mA RCBO. 

You can use 3 Pole 32 Amps iC60 MCB and connect it with the 3 Pole Add-on Vigi Module "A9V02763" (comes with the neutral tail to be connected with the distributed neutral) - this combination is 6 Poles wide 

If balanced three phase system with out neutral you should use Add on Vigi "A9V51363" - this combination is 6½ Pole wide

What is the operating and storage temperature of the I range (iSW) switches.

There are two types of I range switch (iSW Switches) they have different properties and temperature ranges.
The difference is the ISO Standard that the product is manufactured to comply with:
  • IEC/EN 60669
  • IEC/EN 60947-3
For 20-32A they comply with IEC/EN 60669
For 40-125A they comply with IEC/EN 60947-3

The operating temperature of I range switches is:-
  • For IEC/EN 60669 devices between - 20°C...+50°C without derating.
  • For IEC/EN 60947-3 devices -25...+60 °C without derating.

Their storage temperature must be:-
  • For IEC/EN 60669 devices between - 40...+100°C
  • For IEC/EN 60947-3 devices between -40...+85 °C

What is the code for a 32A Type B RCBO for EV chargers?

We do not have any Type B RCBOs available, but this protection can be achieved using a RCCB and MCB.

Single phase = A9Z51240 + A9F54232

3 phase = A9Z51440 + A9F54432
 

Which keys are used with NetShelter cabinets and EcoAisle, and how customers can obtain them.

Issue:
Replacement NetShelter key or additional matching keys are needed.

Product Line: 
NetShelter Cabinets, EcoAisle

Environment:
All versions and serial ranges.

Cause:
Keys may be lost, or spares may be required. 

Resolution:
 
NetShelter Replacement Keys for SX, SV, AV, VX, WX and AR8132A Combination Lock Handles

This document explains which keys are used for various NetShelter cabinets and how to obtain them.

NetShelter SX, SV, AV & VX: 
Please use Part W870-8135 as the replacement key for NetShelter SX, AV and VX front & rear door handles and side panels. This is a single key, not a pair. It’s a sellable part. It can also be RMA’d for in-warrantee replacement. We allow customers one extra key per cabinet as in-warrantee replacement during the first year of ownership. If you need an in-warrantee replacement please call APC customer service and have the cabinet's model number and serial number available.

NetShelter WX:
AR100 and AR100 HD please use Part 840-0103 as the replacement key & door handle kit. 
AR106, AR109 and AR112 please use W870-8135.

NetShelter CX: 
Please use Part 0H-0292-SE as the replacement keys for all NetShelter CX door locks. This is a set of two (2) keys.

AR8132A Combination Lock Handles:
We do not currently stock a replacement key for the AR8132A combination lock handle. If you need to order a replacement key it must be ordered direct from the manufacturer, EMKA. or one of their distributors. The EMKA part number is 1108-U36-222. See below for EMKA contact information.

EcoAisle: 
Key for drop out panels: W870-8135. 
Key for the sliding door: 0J-870-26645. 

EMKA contact information:
United States Headquarters: EMKA Inc.1961 Fulling Mill Road Middletown, PA 17057 Phone: 717-986-1111
European Headquarters: EMKA Beschlagteile GmbH & Co. KGLangenberger Str. 32D-42551 Velbert (Germany)Phone: +49 (0)2051 273-0
For specific regional contacts, please reference EMKA’s website. www.emka.com

What is the Efficiency of the EV Link Chargers?

1) Inside EV Link a mother board with a 24V power supply commanding a contact is installed. 
2) Less than 100W of consumption when the CT is closed. We are just a gate between the grid and the car.

So the maximum consumption is 100w (dedicated to 24v power supply, motherboard, contactor and led). Efficiency will be, 
If the load is a 3,7kW (16A 1P) efficiency = 97%
If the load is a 22kW (32A 3P) efficiency = 99,5%

But, also consider the Harmonics, Power factor produced by the Car itself which will affect efficiency. 
 

What is the replacement model for a NS100N 3 Pole molded case circuit breaker?

The replacement model for a NS100N 3 Pole is the NSX100F 3P range.

NSX100F: (36kA at 415V)
Complete/3 Pole Front Connected
DescriptionTypeTrip UnitRatingPart Number
NSX100F (36kA) Distribution ProtectionStandard thermal-magnetic trip unit TM-DTM16D11-16ALV429637
TM25D17-25ALV429636
TM32D22-32ALV429635
TM40D28-40ALV429634
TM50D35-50ALV429633
TM63D44-63ALV429632
TM80D56-80ALV429631
TM100D70-100ALV429630
Electronic Trip unit Micrologic 2.2 (LSol)40A18-40ALV429772
100A40-100LV429770
Electronic Trip unit Micrologic 5.2A (LSI) (ammeter)40A18-40ALV429882
100A40-100LV429880
NSX100F (36kA)
Motor Protection
Nagnetic only trip Unit MAMA2.52.5A, 0.75kWLV429745
MA6.36.3A, 2.2kWLV429744
MA12.512.5A, 5.5kWLV429743
MA2525A, 11kWLV429742
MA5050A, 22kWLV429741
MA100100A, 45kWLV429740
Electronic Trip unit Micrologic 2.2 (LSol)25A12-25A, 11kWLV429828
50A25-50A, 22kWLV429827
100A50- 100A, 45kWLV429825



There is also a 4P model as well.

Please see link to Product guide - http://www2.schneider-electric.com/resources/sites/SCHNEIDER_ELECTRIC/content/live/FAQS/297000/FA297893/pl_PL/CROSSFER%20NS%20TO%20NSX.pdf