Standard Series, Flush Switch, 1 Gang, 250VAC, 10A, Architrave

Standard Series, Flush Switch, 1 Gang, 250VAC, 10A, Architrave White Electric

Item Number: 30-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Device presentation

basic element with full cover plate and grid

Number of poles

1

Device mounting

flush

Number of rocker

1

Local signalling

without

[ue] rated operational voltage

250 V AC

Rated current

10 A

Marking

without marking

Fixing mode

by screws

Actuator

rocker

Switch function

1-pole

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP120506EN

Circularity profile

N/A

Others

Package 1 bare product quantity

1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3 cm

Package 1 width

3.3 cm

Package 1 length

7.5 cm

Package 1 weight

30 g
Show all specifications

Frequently Asked Questions

hide show

How can I connect SoMove to an Altivar Process drive via Ethernet TCP/IP or Profinet?

Issue:
Connecting SoMove to the VFD using the Ethernet network connection.
 

Product Line:
ATV61 
ATV71 
ATV630
ATV930
ATV320
ATV340
ATV32

Environment:
Ethernet IP or Profinet option installed.
VW3A3316, VW3A3320, VW3A3627 VW3A3720

Cause:
Drive is not detected when attempting to connect.

Resolution:
See attachment for screenshots showing SoMove V2.9.4

STEP 1
Turn OFF your computers firewall before starting so you will have access to your Ethernet port. 
somove Ethernet 32

STEP 2
Edit Connection on your computers ethernet port and setup IP address in the Altivar Drive using an HMI.
Computer or PC setup:
Example setting up your PCs IP address.
Search Ethernet settings
-Change adapter options
- Choose the Ethernet port you want to use.
-Choose Properties
-Make sure IPV4 and IPV6 are both checked. 
-Double click on the IPV4 settings
-Select "Use the following IP address" and now enter in an IP address for your PCs ethernet port. 
Note this IP address needs to match your Drives IP address up to the last octet. 
Drives IP address= 10.172.86.1 (for the Drive) and your PC's IP address = 10.172.86.10 (your computer)
Subnet address= 255.255.255.0
-Choose ok
Somove Ethernet 1

Drive Setup
Example set your Drives IP address using the remote HMI under the Ethernet settings in the programming. 
Type=Fixed
IP address= 10.172.86.1 (for the Drive) 
Subnet address= 255.255.255.0
-Power cycle your Drive after changing the IP address 


STEP 3 
Open up Somove 2.9.4 or newer and setup your "edit connection/scan" settings.
-Click on  "edit connection/scan"
-Choose Modbus TCP double click
-Choose the advanced settings (small gear wheel icon).
-Choose More
-Choose Scan tab
-Now type in your Drives IP address example 10.172.86.1  
-Choose Single Scan and enter 1 
-Apply and OK
-Ok again 
Somove Ethernet 2

STEP 4 
-Now Scan for the Device to see if your PC finds the Drive. 
-double click on the picture of the drive to connect and load from the device.

Somove Ethernet 3

NOTE: If your Drives ATV630 or ATV930 Firmware is version V3.3IE or above it will now include cyber security features and you will have to enter a password before connecting to the drive other Ethernet or Profinet. You can find this unique password on your HMI under the Communications menu, Embedded Ethernet configuration, and find SECE.  SECE select OK on the HMI and then select WDPE and press ok.  Your will now see your unique password example "iY^Nm9cV"
This password is temporary and will need to be changed and remembered.

The USERNAME: ADMIN (all caps)
The Password: iY^Nm9cV (for this example only) 

FAQ cyber security 1

FAQ cyber security 1a

FAQ cyber security 1n

Please read and understand before checking OK. 

Somove ethernet 4

Somove is loading settings from the Drive to your Somove on your PC. 

somove ethernet 5b


Your are now connected to the Drive when the bar across the top turn's orange. 

Somove Ethernet 6a


Please be aware that you will be required to enter a password when you connect via Ethernet or Profinet if your Process Drive is version V3.3IE or higher so if you live in an area or work for a company that does not require or mandate having a password for Ethernet or Profinet for cyber security you can disable the feature if desired.  Otherwise leave the feature active which can offer the best cyber security. 

FAQ cyber security 1b


Done.  


NOTE:  

This example should work using. 
-Ethernet TCP
-Ethernet IP
-Profinet

 

 
 
 
 
 

What does the SOC indication mean on the Altivar 630 Process drive?

Issue:
SOC indication meaning on the Altivar 630 Process drive.

Product Line:
Altivar 630 Process

Environment:
All serial numbers for Altivar Process

Cause:
N/A

Resolution:
SOC means [Stand by output contactor].
You will need to check you OPL (Output Phase Loss) settings under [Complete settings] [Error/Warning handling] [Output phase loss].
Look at oAC settings - No detected error triggered, but management of the output voltage in order to avoid an over current when the link with the motor is reestablished and catch on the fly performed (even if this function has not been configured).The drive switches to [Output cut ]SOC state after [OutPhL Time] Odt time. Catch on fly is possible as soon as the drive is in stand by output cut [Output cut] SOC state.
 

When comparing projects with a BMENOC3xx in Unity Dif, what does the “ParamKW” refer to?

UnityDif
If the value of ParamKW is different, then it is referring to any modification done on the configuration of the NOC (most likely in the DTM browser). If you do not see any changes in this section of the program, then no actual modification was done. For example, if the IP address of a device in the DTM browser is changed and then changed back to its original value, a time stamp will still exist, resulting in the ParamKW changing.
DTM

How can you change the maximum speed on the ATV31 or ATV312 drives so that the motor can operate above 60Hz?

Issue:   
How can the motor operate above 60Hz in the ATV31 or ATV312 drives?
 
Product Line:   
ATV31 ATV312
 
Environment:  
All
 
Cause:  
Changing high speed / max frequency
 
Resolution:   
Parameter HSP determines the maximum speed the drive can operate.  Parameter tFr determines the maximum value that HSP can be adjusted.  

By default, tFr is set to 60Hz.  When changing the Motor Frequency - bFr this changes tFr to 72Hz.  

To increase the maximum speed above 72Hz - Go to the drc menu and Set parameter tFr.  This can be adjusted up to 500Hz.  After saving the change, go to the SEt menu > HSP and adjust up to the desired speed.  

If your motor is a specialty motor that is rated for a frequency other than 50Hz. or 60Hz. such as a 300Hz. rated spindle motor, change parameter FrS under the DRC menu to match the rated frequency of the motor.

 

Can you feed 230vac into an 480vac Altviar ATV drive to run a 230vac motor?

Issue:
Wha happens if you feed 230vac into an 480vac Altviar ATV drive to run a 230vac motor?

Product Line:
Altivar ATV61, ATV71, ATV312, ATV212 ATV32

Environment:
All

Cause:
They ordered the wrong drive with 480vac they need a 230vac drive can they use the 480vac to run the 230v motor?

Resolution:
No you will need to order the correct drive to match the motor amps, hp and application.

What is the replacement for a NS100N with TM100D Trip unit?

The replacement for a 3 poles 3d NS100N with TM100D Trip unit is NSX100F = LV429630
It is the same dimensions.
LV429630


For further information refer to:
https://download.schneider-electric.com/files?p_enDocType=Catalog&p_File_Name=LVPED217032EN.pdf&p_Doc_Ref=LVPED217032EN

How far can you remote mount the remote HMI or VW3A1101 keypad?

Issue:
Max. distance that the VW3A1101 can be mounted?

Product Line:
Altivar ATV61 and ATV71 with a VW3A1102 remote mounting kit.

Environment:
All

Cause:
Installation

Resolution:
We offer remote cable options up to 10 meters in length.  
Please keep in mind we cannot recommend that the HMI will work with any cable above 10 meters.  

We offer 4 cable options:
1 meter    VW3A1104R10
3 meter    VW3A1104R30
5 meter    VW3A1104R50
10 meter  VW3A1104R100

If you want to try running a longer cable, you can try using a standard CAT 5 type cable to connect between the remote HMI and the Drive. Some OEMs have ran cables up to 200 feet however they had to add an external power supply to compensate the long cable length ( See the attachment for OEM example of 200 ft cable run). We cannot recommend doing this, but we've been informed that it has been done.

Are output filters and line reactors the same on VFDs?

Issue:
Output filters vs Line reactors

Product Line:
Drives.

Environment:
N/A

Cause:
Product features.

Resolution:
No. Output filters and Line reactors are not the same thing. (Load reactor if applied to the output)
Filters reduce DV/DT at the motor by filtering high frequencies. This helps protect the motor.
Line reactors add impedance to the line. This reduces current distortion between the drive and motor if applied to the output. It reduces current distortion on the line when applied to the line side of the drive.
See the information for the specific device for additional details.

Filter info at: http://www.transcoil.com/#klc
Reactor info at: https://mtecorp.com/products/reactors/

What is the replacement main control board part number for ATV61 drives?

What are the input circuit requirements for an EV Charging Station?

Issue:
What are the feeder circuit requirements for an EV Charging station?

Product Line:
PTEVC - ELECTRICAL VEHICLE

Resolution:
The EVlink series of Level 2 charging station require a 40A, non-GFI type breaker for each charging outlet.  #8 wire is required (L1, L2, and GND).  For dual outlet charging stations, two 40A non-GFI breakers will be required (one for each charging outlet).  A neutral connection is not required for EVlink stations.
A 40A circuit breaker is required as the continuous output current from the charging station can be as high as 30A. 
The wiring diagram for a single outlet charging station is shown in the figure below.
EVlink Basic Wiring Diagram

How do you order a Masterpact NW or NT circuit breaker?

Issue:
What is the process for ordering a Masterpact NW or NT circuit breaker?

Product Line:
Circuit Breakers

Resolution:
Masterpact circuit breakers cannot be ordered by catalog number.  A Schneider distributor or sales office must enter the order via the online product selector in My Schneider, SE Advantage, or Quote to Cash.
Information they need includes the certification standard (UL, ANSI, IEC), fixed or drawout, ampacity, AIR required, trip unit functions or type, accessories, connectors, and other customer specifications.

The attached decoder will assist in breaking down a catalog number to its component parts.  With knowledge of the breaker's construction it will be possible to use the Q2C or SE Advantage product selector to select, quote, and order the breaker.  DO NOT try to build a catalog number using the decoder.  A number generated using the decoder will be prone to error due to possibly selecting components and features which are mutually exclusive, and the number will have no value for quotation or ordering even if valid.

Required information for placing an order can be found on the attached RFQ (Request for Quote) or RFQ - DC for DC rated Masterpacts.

Do the electronic boards of the Altivar 61 and Altivar 71 drives have conformal coating?

Issue:
Do Altivar 61 and Altivar 71 electronic boards have conformal coating?

Product Line:
Altivar ATV61 and ATV71

Environment:
NA

Cause:
Needs to know if you can order the ATV61 ATV71 drive with conformal coating?

Resolution:
The Conformal Coating is standard on:
 
Part NumberDescription 
ATV61HC40N4ATV61 400KW 600HP 480V 3PH EMC
ATV61HC50N4ATV61 500KW 700HP 500V 3PH EMC
ATV61HC63N4ATV61 630KW 900HP 480V 3PH EMC
ATV71HC31N4ATV71 480V 315KW 500HP EMC
ATV71HC40N4ATV71 480V 400KW 600HP EMC
ATV71HC50N4DATV71 480V 500KW 700HP EMC w/o choke
ATV71HC50N4ATV71 480V 500KW 700HP EMC

These products are treated for increased protection for dusty and corrosive environments. With this coating, exposed copper is tinned, circuit boards are conformal coated in critical areas and plastics are treated to better withstand the corrosive nature of certain oils.

The ATV61 and ATV71 drives are designed for maximum ambient pollution as follows:
ATV71:
H...M3, 71HD11M3X, HD15M3X, H075N4 to HD18N4 are Degree 2 conforming to IEC/EN 61800-5-1
HD18M3X to HD75M3X, HD22N4 to HC50N4 are Degree 3 conforming to IEC/EN 61800-5-1

ATV61:
H...M3, HD11M3X, HD15M3X, H075N4 to HD18N4 are Degree 2 conforming to IEC/EN 61800-5-1
HD18M3X to HD90M3X, HD22N4 to HC63N4 are Degree 3 conforming to IEC/EN 61800-5-1

Video: How is a faulted Altivar drive reset?

Issue:
Reset a  fault on a Altivar drive.

Product Line:
Altivar ATV variable speed drives

Environment:
All

Cause:
Need to reset a fault status.

Resolution:
There are multiple ways to reset a fault, including a logic input assignment and communication network.  But an easy way to reset a fault is to remove line voltage from L1,L2,L3.  Allow enough time for the display to go completely blank and then wait another 30seconds.  Reapply power.  If the fault appears again, it means that the VFD has re-faulted.

Note: Some faults have to be reset by removing and reapplying line voltage (power-cycling) the drive. Refer to your drive's Programming Manual for a list of faults that require a power cycle to clear. 

The following video demonstrates how to configure a logic input fault reset function on the Altivar 212:

Does VAP6 need calibration?

VAP6 device does not need calibration. Please check the attached document.

What is the replacement for NS630H with STR23SE trip unit?

The alternative replacement for NS630H with STR23SE trip unit is the new offer Compact NSX new Generation C63H32D630.


C63H32D630

Circuit breaker, ComPacT NSX630H, 70kA/415VAC, 3 poles, MicroLogic 2.3 trip unit 630A

Are the ATV Process drives (ATV630, ATV650, ATV930, ATV950) conformal coated? What about the ATV320 and ATV340?

Issue: 
ATV Process and ATV Machine drives conformal coated.

Product Line:
ALTIVAR 630
ALTIVAR 650
ALTIVAR 930
ALTIVAR 950
ALTIVAR 320
ALTIVAR 340

Environment:
All
 
Cause:
N/A

Resolution:
Altivar Process (ATV6x0 and ATV9x) withstand to harsh environments:
- Chemical class 3C3 conforming to IEC/EN 60721-3-3.
- Mechanical class 3S3 conforming to IEC/EN 60721-3-3.
Except:
- Altivar Process ATV630C22...C31N4 drives are certified as chemical class 3C2 and mechanical class 3S2 conforming to IEC/EN 60721.
- Altivar Process ATV930C22...C31N4 drives are certified as chemical class 3C2 and mechanical class 3S2 conforming to IEC/EN 60721.

Altivar Machine (ATV320 and ATV340) withstand to harsh environments:
- Chemical class 3C3 conforming to IEC/EN 60721-3-3.
- Mechanical class 3S2 conforming to IEC/EN 60721-3-3.

However, in all cases, there are no published certificates that we can send out. 

What does "Connection in progress" mean on ATV630/ATV930 drives?

Issue:
Getting 'Connection in progress' on ATV630/ATV930 drives.

Product Line:
Altivar 630 Process Drive

Environment:
All serial numbers for Altivar 630 Process Drive

Cause:
N/A

Resolution:
This issue indicates the keypad is getting power from the drive but it is not communicating with it.
This almost always indicates the communication settings for the port are no longer at default.
  1. If SoMove or webserver connection is available, check the Modbus HMI baudrate and format.  The keypad is fixed at 19200 baud are requires 8 bits, Even parity, 1 stop bit. Changes to the communication settings are only taken into effect after reset, so a power cycle may be required. d
  2. If the keypad is remote mounted, and plugged into the HMI port on the front of the drive, move the connection cable to the Modbus network port since (as shown above) the default settings are compatible. If the keypad communicates, navigate to the Menu 6: Communication and then set the Modbus HMI baudrate to 19200 and the format to 8E1.  After power cycling the drive, move the keypad back to it's original port. 
  3. You might have a loose HMI or a remote cable. Try re-seating the HMI and remote cable. 
  4. If you've confirmed baudrate and format are set properly and that power has been cycled to the drive, try a known good keypad.
  5. Make sure there is no control voltage drop or grounding issues.
If issues remain the drive may require repair or replacement parts so contact Technical Support for further assistance.

When was the LH4N soft start line made obsolete?

Issue:
Customer wants to know when the LH4N soft starts became obsolete

Product line:
LH4, LH4N

Environment:
All models

Cause:
Obsolete

Resolution:
The LH4N became obsolete in January 2005.  The current replacement product for form, fit and function is the ATS01 soft start series.  Customers should still review the product ratings and dimensions before ordering. 
The Installation Manuals for the LH4N and the ATS01 are attached. 
 

What fault is used on the Process Drive to indicate cavitation?

Issue:
How does Process Drive indicate Cavitation detection?
 
Product Line:
ATV630
 
Environment:
All models and serial numbers
 
Cause:
None
 
Resolution:
The fault used to detect cavitation is "Inlet pressure fault". 
  Inlet Pressure Fault image

 

Video: How to setup Plus/Minus Speeds on the Altivar Process Drive

Issue:
Set up Plus/Minus Speeds on the Altivar Process Drive.

Product Line:
Altivar Process Drive (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)

Environment:
All serial numbers for Altivar Process Drive

Resolution:



To Program the +/- Speeds
  1. [Complete settings] [Command and Reference]
  2. Set [Freq Switch Assign] rFC to [Ref Freq Channel 2] FR2
  3. Set [Ref Freq Channel 2] FR2 to [Ref Frequency via DI] UPdt
  4. Go to [Complete settings] [Generic functions] [+/- speed]
  5. Assign [+ Speed Assign] USP
  6. Assign [- Speed Assign] dSP
  7. Assign [Ref Frequency Save] Str

    To adjust the increment of plus and minus speed, adjust the ACC and DEC. If ACC is set to 6 seconds, it will ramp 10 Hz for every second that the +speed is active (60Hz range / 6sec = 10Hz/sec).  Keep it active for 6 seconds and output will reach 60 Hz. To make +speed increase at a slower rate, increase ACC.  To make it faster, decrease ACC.  The same logic applies to -speed and DEC.

     
Reference the attached document for more information

What can cause the ATV630 Process Drive not connect to WIFER?

Issue:
ATV630 Process Drive not connecting to WIFER.
 
Product Line:
ATV630, ATV930, Process Drive
 
Environment:
All models using the WIFER TCSEGWB13FA0 Wi-Fi Access Point
 
Cause:
Cannot connect to WiFi.
 
Resolution:
1.The demo box has two cables with RJ45 connectors.  The larger of the two is a Modbus cable and cannot be used to connect to the Wi-Fi.  The smaller flat cable which also has RJ45 connectors on each end is the cable needed for the Ethernet connection to the WIFER.  See the attached picture.
2. Disconnect from local LAN, if connected. Discover the Wifer device on available networks. Double-Click to connect. Then open a Browser and goto www.a.com.
3. Depending on release version of the OS of your laptop, tablet, the WIFER WEB site is automatically opened as soon as the Web Browser is launched. But with other OS it could be necessary to enter a simple URL like "www.a.com" in the Browser line to force the Browser to open and show the WIFER Web site.
4. Deactivate Pop up blocker.
 

What is the part number of the USB cable used to connect a PC to a drive or soft start when using SoMove?

Issue:
Cable part number to connect a PC to a drive or soft start when using SoMove or Powersuite?

Product Line:
ATV Altivar Drive ATS Altistart Soft starter

Environment:
All current products

Resolution:
TCSMCNAM3M002P:  This cable is a USB to RS485 interface cable to be used with SoMove and Powersuite.
The cable connects to the the ModBus port on the drive and a USB port on a PC. 

cable image
Note: If using this cable with SoMove, then the SoMove software must be installed on your PC prior to plugging this cable into the USB port on the PC. The driver for this cable is now included in the core SoMove software. And it's important that your PC uses this driver as opposed to a driver that Windows would install automatically.

Video: How do I apply the vinyl skin for my EVlink charger?

Issue:
The application of the vinyl skin to EVlink residential units.

Product Line:
PTEVC - Electric Vehicles

Resolution: 
The video below highlights the application process.

What is the resistance value of the VW3A7703 braking resistor?

Issue:
Resistance value of the VW3A7703 braking resistor.

Product Line:
VW3A7703 braking resistor

Environment:
Part number VW3A7703 only.

Cause:
Customer needs to know the ohmic value of this resistor

Resolution:
The resistance value of the VW3A7703 braking resistor is 28 ohms at 20 degrees C.

What parts are needed for remote mounting the ATV61/71 VW3A1101 keypad?

Issue:
Part number required for remote mounting the ATV61/71 with the VW3A1101 keypad.

Product Line:
VW3A1101 keypad for ATV61 ATV71 drives

Environment:
All

Cause:
Installation

Resolution:

The mounting kit, including bezel and hardware is VW3A1102

The Modbus cables to connect the keypad to the control basket of the drive are:
1 Meter -      VW3A1104R10                        
3 Meters -    VW3A1104R30
5 Meters -    VW3A1104R50
10 Meters -  VW3A1104R100
Cable

The clear plastic door (IP 65 rating) to cover the keypad when not in use is VW3A1103

Installation Image






 

How to control the speed of the Altivar 630 Drive with Local HMI?

Issue:
ATV630 speed control with local HMI

Product Line:
Altivar ATV600 and ATV900 series drives

Environment:
All 

Cause:
The drive's speed is to be controlled by the local  HMI

Resolution:
Enter the Main Menu of the Drive. Go to Complete Settings then go to Command and Reference. In this Menu, the first parameter is Ref Freq 1 Config which is set to AI1 (Factory default), change this parameter to Ref Freq-Rmt Ter

Main Menu -> Complete Settings -> Command and Reference
-> HMI CMD to Bumpless (Default is Disabled)
-> Ref Freq 1 Config -> Ref Freq-Rmt Term
-> If Start/Stop  from Terminals and Speed control from HMI, Control Mode must be changed to Separate

How does the ATV630 Process drives stall function work?

Issue:
How to set up stall function on the ATV630 Process drive?

Product Line:
Altivar 630

Environment:
All serial numbers

Cause:
Stall function

Resolution:
This function helps to prevent a motor overload by monitoring the motor current and the speed rise time. 
A stalling condition is when: 
An output frequency is smaller than the stalling frequency [Stall Frequency] StP3 
And an output current is higher than the stalling current [Stall Current] StP2 
During a time longer than the stalling time [Stall Max Time] StP1 
That means that you must meet three conditions, then a stalling condition occurs, an [Motor Stall Error] StF error is triggered. 

For example,
Set StP3=10HZ, StP2=100% (meaning rated motor current)
StP1=5s 
When the drive is running at 9.9HZ, motor current is above rated motor current, then after 5S, an [Motor Stall Error] StF error is triggered. 
If the drive is running at 10.1HZ, an StF error is not triggered.

What is the warranty period for EVlink electric vehicle charging stations?

Issue:
What is the warranty period for EVlink electric vehicle charging stations

Product Line:
PTEVC - ELECTRICAL VEHICLE

Resolution:
The EVlink stations are covered by an 18 month warranty as described in section 12 of the Schneider Electric Terms and Conditions of Sale. These can be reviewed here .
This warranty does not cover the consumable items of the EV station, namely the J1772 cable (EVCABLER) or the cable dock (EVCABLEDOCK).
EVlink_Family

What is the password to the embedded Ethernet Modbus TCP Webserver on the Altivar Process Drive?

Issue:
Password for the Altivar Process Drive embedded Ethernet Webserver.

Product Line:
Altivar Process Drive (ATV630, ATV930, ATV650, ATV950, ATV660, ATV960, ATV680, ATV980)
Altivar Machine Drive (ATV340 E version)

Environment:
All models and serial numbers for Altivar Process Drive
 
Cause:
Reset the password of the Embedded Ethernet Modbus TCP webserver

Resolution:
[My preferences] [Webserver]


ATV600 series Firmware < V1.5: The default User ID and password is: ADMIN  
ATV600 drives with Firmware V1.5 or higher no longer support ADMIN as a default password. The password is now unique to the drive and has to be looked up in the webserver submenu 8.7.
ATV900 series implemented the password change beginning with V2.1.
ATV340 E implemented this change with V1.6.
NOTE: The password is not shown unless the drive has an IP address assigned (either through DHCP server or fixed IP settings).
The default  User ID remains Admin (not case sensitive).

There has been an additional cyber security update to the drives that requires the default password to be changed on first connection via Ethernet (Webpage or SoMove). 
This was implemented in V3.3 for ATV600/ATV900 and in V3.2 for ATV340 E.
This enhancement means you will be required to enter the default password (available on the keypad) and then will be required to enter a new password to access the drive.
Password policies can be modified using SoMove or from the Webserver.

It is possible to disable this cybersecurity function from the keypad or via SoMove/webserver but caution should be used before doing so, since this can compromise the security of the system.

SoMove connections via the Modbus port are not impacted.
 

What is a good source of information for the ATV12?

Issue:
Looking for ATV12 information

Product Line:
Altivar 12

Environment:
All models and serial numbers

Cause:
Information is needed for installation and programming.

Resolution:
User manual is document number BBV28581.  This manual includes instructions for installing the drive, connecting the control wiring, programming and troubleshooting.
https://www.schneider-electric.us/en/download/document/BBV28581/

What is a good source of information for the ATS48 soft start?

Issue:
Information is needed to facilitate installation and programming

Product line:
Altistart ATS48

Environment:
All models, all serial numbers

Cause:
None

Resolution:
Instruction Bulletin, S1A37491, includes information for installing and programming the ATS48.
Instruction Bulletin, 30072-451-28, is a Maintenance and Repair manual.

Use this URL to get to the ATS48 product page:
https://www.schneider-electric.com/en/product-range/689-altistart-48/

Do we have a 230V single-phase input enclosed drive for a three-phase motor?

Issue:
230V single-phase input enclosed drive for a three-phase motor product selection

Product Line:
ATV61/71

Environment:
Irrigation Field Drive
 
Cause:
None

Resolution:
Schneider Electric provides a solution for single phase input, running a three phase motor with the Irrigation Field Drive.  
Specific information can be found in the Altivar 61/71 Field Drive manual number 30072-454-01


 

Where can I get a list of the ATV630, process drive, communication parameters?

Issue: 
Communication parameters for the ATV630
 
Product Line:
Altivar 630
 
Environment:
All serial numbers
 
Cause:
N/A
 
Resolution:
Click the link below to download the latest of ATV630 communication parameters.

https://www.schneider-electric.us/en/download/document/EAV64332/

Will an FAL or FHL breaker that has an electrical accessory such as shunt trip, undervoltage trip, auxiliary switch, or alarm switch fit into a standard FA enclosure?

Issue:  
Need to know if my FAL breaker will install in an enclosure with an accessory installed in it.  

Product line:  
Molded case circuit breakers

Resolution:  
Yes. These accessories are internal to the breaker frame and require no extra enclosure room.  

What are components in the 9001KYK116?

Issue:
Identify the parts break down of a 9001KYK116

Product Line:
30mm, 9001KY/SKY Control Stations

Environment:
Pushbuttons and Operator Inteface

Resolution:
9001KY1 - Enclosure
9001K15 - Emergency Break Glass Operator
9001KA1 - 1NO and 1NC Contact Block
9001KN799RP -  Legend Plate (Special Marking)

What is the height of our pushbutton guard ZB4BZ1905?

Issue:
ZB4BZ1905 Height Dimensions

Product Line:
Push Buttons and operator interface

Environment:
Harmony XB4/ZB4 Metal Push Buttons

Cause:
Product Specifications

Resolution:
Height is 38mm.

What is the difference between 9001KYG1Y1 and 9001KYG1Y2?

Issue:
9001KYG1Y1 and 9001KYG1Y2 Difference

Product Line:
30 mm Enclosures

Environment:
9001KY/SKY Control Stations

Resolution:
9001KYG1Y1 includes a push/pull operator 9001KR9R
9001KYG1Y2 includes a turn to release operator 9001KR16.  

Both have the same 9001KYG1Y enclosure with the same 9001KA3, one normally closed contact block.

Video: How to wire start/stop command to an Altivar Process Drive?

Issue:
How to wire start/stop command to an Altivar 630 & 930 Process Drive?

Product Line:
Altivar Process Drive

Environment:
All serial numbers for Altivar Process Drive

Resolution:
2 wire control
Wiring
Maintain Contacts
Wire the run contact between terminals DI1 and 24V.

3 wire control
Wiring
Momentary Contacts
Wire Normally Closed Contacts (Stop Button) on DI1 and 24V
Wire Normally Open Contacts (Start Button) on DI2 and 24V

Programming
To alternate between 2 and 3 wire control is done in the Programming Menu
[Complete settings] [Command and Reference] [2/3-wire control] tCC

 

Is it possible to transfer the ATV71 program to ATV930?

Issue:
Wants to know if the old parameters of the ATV71 can be transferred to the ATV930?

Product Line:
Altivar ATV71 ATV930

Environment:
All

Cause:
Programming 

Resolution:
No. The ATV930 has a different memory may and different capabilities than the older ATV71.
The program files are not compatible.

Where can I find specifications for an ATV212 S-Flex?

Issue:
Looking for the specifications for an ATV212 S-Flex. 

Product Line:
ATV212

Environment:
S-Flex all models

Cause:
Need specifications for an S-FLEX

Resolution:
See the latest S-Flex Instruction bulletin, which contains the basic specifications, wiring diagrams, etc for the S-Flex enclosed product.

https://www.schneider-electric.us/en/download/document/30072-451-83/
               

Is the ATV630 (or ATV930) Process drive available with 1 phase input and 3 phase output?

Issue:
Are the Process drives available with single phase input and 3 phase output?

Product Line:
Altivar 630
Altivar 930

Environment:
Application 

Cause:
Wants to know if the ATV630 Process drive is offered in 1 phase input 3 phase output. 

Resolution:
The ATV630 is approved for some single phase input, 3 phase output applications. 
See the current Annex to the Getting Started with Altivar Process ATV600 document below:
https://www.schneider-electric.com/en/download/document/EAV64300/

This document lists models for 240V and 480V Pump applications.
Note: Do not use ATV630D55M3 and ATV630D75M3 for 1-phase application.

At this time, no ATV900 Process drives are approved for single phase supply.  They are designed strictly for 3 phase input power to run a 3 phase motor.

The ATV900 series may be used in conjunction with a 3rd party input bridge from a company like Bonitron (Bonitron Solutions for Schneider Drives) .
Contact Bonitron directly for assistance.

Where do I connect an external +24vdc power supply on the ATV630 process drive?

Issue:
External power supply connection
 
Product Line:
ATV630
 
Environment:
All models and serial numbers
 
Cause:
None
 
Resolution: 
The external +24vdc power supply must be connected to terminals P24 and 0v.  The positive is P24 and the negative is 0v. 
DO NOT connect the external power supply to +24v.
No programming changes are required.

How to disable the password to the Embedded Ethernet Modbus TCP Webserver on Altivar Process Drive ?

Login with full access account to Webserver, navigate to "Setup", select "Access Management", then choose "Off". The password is disabled when the screen refreshes. 
Setup - Access Management

Altivar Process : How to connect to a Webserver - https://www.youtube.com/watch?v=8qULiamjhco

 

What is the parts breakdown of a 9001KP1R31?

Issue:
9001KP1R31 components

Product Line:
Push Buttons and Operator Interface

Environment:
Harmony Pushbuttons

Resolution:
It consists of a 9001KM1 light module, 9001KP operator and a 9001R31 lens.

What is the outside diameter and depth of the 9001K68 / 9001K685 mushroom button guards?

Issue:
9001K68 / 9001K685 mushroom button guards dimensions

Product Line:
30mm Class 9001 Type K Harmony Pushbuttons

Environment:
Type K and SK Accessories

Resolution:
Outside diameter: 2.75 inches (70 mm)
Depth: 1.14 inches (29 mm)

What is available in ATV630 and ATV650 Multipump Control?

Issue:
ATV630 and ATV650 Multipump Control

Product Line:
Altivar Process, ATV630, ATV650

Environment:
All

Cause:
NA

Resolution:
The multipump feature available in the ATV630/650 drive currently is one Variable VFD pump and multiple fixed speed pumps. 
Alternation of pump can be done as well and uses a relay to trigger external contactors to switch which pump is connected to the drive.

How to get Security Station Replacement Keys

Issue:
Can you provide replacement keys for the 9001KZC297 Security Control Station?

Product Line:
Class 9001 Type K, SK, KX control stations

Environment:
Push Buttons and Operator Interface

Resolution:
The replacement keys for this Security Control Station must be purchased directly through Best Lock Corporation.
© 2010 Stanley Security Solutions, Inc.
6161 East 75th Street | Indianapolis, IN | 46250
Tel 317 849 2250 | Cust Srv 855 365 2407

Where can I download the Visio and CAD for Dafligateway2 (5502CDGP230)

Please see attached Visio and CAD for Dafligateway2 (5502CDGP230)

Visio and CAD for Dafligateway 2 5502CDGP235
 

What is the difference between the 9001K20 and the 9001K21?

Issue:
What single potentiometer operator with single pot should be used with 10 ohms?

Product Line:
Harmony Push Buttons

Environment:
Harmony 9001K potentiometer

Cause:
Product Features

Resolution:
The 9001 K20 is the operator only without the single pot. The 9001 K21 is the operator with the single pot.

What is the difference between (5502DAL + DCDALCIP250-2) Old Vs 5502CDGP230 New Hardware?

Dimension wise - 8 module vs 6 modules wides

Built in DALI PS - Separate vs Build in dali power supply

C-Bus Current draw 32mA vs 20 mA

Dali Compatible Vs Dali2 Compliance…


Dali 5200DAL vs 5502DCGP230
 
Show More