Standard Series, Flush Switch, 1 Gang, 1-Way/2-Way, 250VAC, 10A, Miniature Architrave

Standard Series, Flush Switch, 1 Gang, 1-Way/2-Way, 250VAC, 10A, Miniature Architrave White Electric

Item Number: 30T-WE

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Sustainable offer status

Green Premium product

Physical

Device presentation

basic element with full cover plate

Device mounting

flush

Number of rocker

1

Local signalling

without

[ue] rated operational voltage

250 V AC

Rated current

10 A

Marking

without marking

Fixing mode

by screws

Actuator

rocker

Switch function

1-way|2-way

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP120506EN

Circularity profile

N/A

Others

Package 1 bare product quantity

1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3 cm

Package 1 width

11.4 cm

Package 1 length

9.7 cm

Package 1 weight

21 g

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A
Show all specifications

Frequently Asked Questions

hide show

Where do I find drawings for the most common EX Three Phase Ventilated Transformers, such as an EX75T3H?

Issue:
Drawings for common EX Transformers

Product Line:
LV Transformers

Environment:
Applies to Low Voltage Ventilated EX Transformers by SquareD/Schneider Electric

Cause:
Transformers for some applications require drawings

Resolution:
There is a Website set up for the purpose of obtaining Three Phase Ventilated EX Transformer drawings.  Drawings for common three phase EX type Transformers may be obtained by using this link:

http://www.schneider-electric.us/en/product-range-download/63362-doe-2016-square-d-energy-efficient-ex-transformers/?filter=business-4-electrical-distribution&parent-category-id=53700


 

Can a 60 Hz rated Transformer be energized with 50 Hz source?

Issue:
Transformers rated for 60 Hz ONLY are sometimes chosen to be installed in a location that has a 50 Hz Distribution system. 

Product Line:
LV Transformers 

Environment:
Applies to MOST Transformers made by SquareD/Schneider Electric.  Exceptions are 9070 series Control Transformers and Export Model Transformers which are dual rated for 50Hz and 60Hz.

Cause:
Domestic (USA) power systems are rated 60 Hz.   Many other power systems in the world are rated at 50 Hz.

Resolution:
A 60 Hz rated transformer can only be used on a 60 Hz system (with certain exceptions -- read further.) Whereas a 50 or 50/60 Hz rated transformer can be used on either a 50 or a 60 Hz rated system.
Exception: If the energizing voltage does not exceed 83% of the transformers nominal voltage, the transformer can be used. Remember that transformers are simple ratio devices and the output will also be lower. Another important factor to remember is that the transformer`s capacity will also have to be derated at the same ratio of the applied voltage divided by the nominal voltage.

Example: An EXN30T3H, 30kVA 480 delta to 208Y/120 transformer 60 Hz, can be utilized on a 50 Hz system as long as the applied voltage does not exceed 50/60 or 5/6 of the nominal 480, or rather 400 volts. With 400 volts 50 Hz applied, the output voltage will be 400/480 * 208 = 173 volts line-to-line, and 100 volts line-to-neutral, or 173Y/100 50 Hz. As well, the capacity or kVA of the transformer will be 400/480 * 30 = 25kVA. Transformers cannot change frequency, thus frequency in = frequency out.