Standard Series, Flush Plate, Architrave Size, Switch Plate 1 Gang (75 x 32mm)

Standard Series, Flush Plate, Architrave Size, Switch Plate 1 Gang (75 x 32mm) White Electric

Item Number: 31-WE

Datasheet

Product Dimensions

Width icon

Width32 mm

Height icon

Height72 mm

Depth icon

Depth11 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Product destination

switch

Sustainable offer status

Green Premium product

Physical

Fixing mode

by screws

Marking

without marking

Mounting position

horizontal and vertical

Fixing center

55 mm

Width

32 mm

Height

72 mm

Depth

11 mm

Number of gangs

1 gang

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP120506EN

Circularity profile

N/A

Material

Material

plastic

Others

Package 1 bare product quantity

1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

1 cm

Package 1 width

8.2 cm

Package 1 length

11.8 cm

Package 1 weight

15 g

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A
Show all specifications

Documents & downloads

hide show

Frequently Asked Questions

hide show

How can I connect SoMove to an Altivar Process drive via Ethernet TCP/IP or Profinet?

Issue:
Connecting SoMove to the VFD using the Ethernet network connection.
 

Product Line:
ATV61 
ATV71 
ATV630
ATV930
ATV320
ATV340
ATV32

Environment:
Ethernet IP or Profinet option installed.
VW3A3316, VW3A3320, VW3A3627 VW3A3720

Cause:
Drive is not detected when attempting to connect.

Resolution:
See attachment for screenshots showing SoMove V2.9.4

STEP 1
Turn OFF your computers firewall before starting so you will have access to your Ethernet port. 
somove Ethernet 32

STEP 2
Edit Connection on your computers ethernet port and setup IP address in the Altivar Drive using an HMI.
Computer or PC setup:
Example setting up your PCs IP address.
Search Ethernet settings
-Change adapter options
- Choose the Ethernet port you want to use.
-Choose Properties
-Make sure IPV4 and IPV6 are both checked. 
-Double click on the IPV4 settings
-Select "Use the following IP address" and now enter in an IP address for your PCs ethernet port. 
Note this IP address needs to match your Drives IP address up to the last octet. 
Drives IP address= 10.172.86.1 (for the Drive) and your PC's IP address = 10.172.86.10 (your computer)
Subnet address= 255.255.255.0
-Choose ok
Somove Ethernet 1

Drive Setup
Example set your Drives IP address using the remote HMI under the Ethernet settings in the programming. 
Type=Fixed
IP address= 10.172.86.1 (for the Drive) 
Subnet address= 255.255.255.0
-Power cycle your Drive after changing the IP address 


STEP 3 
Open up Somove 2.9.4 or newer and setup your "edit connection/scan" settings.
-Click on  "edit connection/scan"
-Choose Modbus TCP double click
-Choose the advanced settings (small gear wheel icon).
-Choose More
-Choose Scan tab
-Now type in your Drives IP address example 10.172.86.1  
-Choose Single Scan and enter 1 
-Apply and OK
-Ok again 
Somove Ethernet 2

STEP 4 
-Now Scan for the Device to see if your PC finds the Drive. 
-double click on the picture of the drive to connect and load from the device.

Somove Ethernet 3

NOTE: If your Drives ATV630 or ATV930 Firmware is version V3.3IE or above it will now include cyber security features and you will have to enter a password before connecting to the drive other Ethernet or Profinet. You can find this unique password on your HMI under the Communications menu, Embedded Ethernet configuration, and find SECE.  SECE select OK on the HMI and then select WDPE and press ok.  Your will now see your unique password example "iY^Nm9cV"
This password is temporary and will need to be changed and remembered.

The USERNAME: ADMIN (all caps)
The Password: iY^Nm9cV (for this example only) 

FAQ cyber security 1

FAQ cyber security 1a

FAQ cyber security 1n

Please read and understand before checking OK. 

Somove ethernet 4

Somove is loading settings from the Drive to your Somove on your PC. 

somove ethernet 5b


Your are now connected to the Drive when the bar across the top turn's orange. 

Somove Ethernet 6a


Please be aware that you will be required to enter a password when you connect via Ethernet or Profinet if your Process Drive is version V3.3IE or higher so if you live in an area or work for a company that does not require or mandate having a password for Ethernet or Profinet for cyber security you can disable the feature if desired.  Otherwise leave the feature active which can offer the best cyber security. 

FAQ cyber security 1b


Done.  


NOTE:  

This example should work using. 
-Ethernet TCP
-Ethernet IP
-Profinet

 

 
 
 
 
 

Why will the ATV312 drive not run the motor with a run command present?

Issue:
The ATV312 drive will not run the motor, with a run command present. 

Product Line:
ALTIVAR 312

Environment:
All
 
Cause:
No output voltage

Resolution:
Verity line voltage and control voltage is present:

  • Measure AC line voltage phase to phase 
  • Measure DC voltage between the +24 terminal and the COM terminal 

Verify mode of operation remote or local modes:

  • If the red LED's on the left-hand side of the drive's display are:
    • Off- The drive is in remote (terminal) control 
    • Scrolling (flashing in sequence)- The drive is in local control 
    • Flashing together- The drive is in local, programming mode. It will not run in this mode. Hold down the ESC key for 2-3 seconds to return to local mode

Verify the run command is valid: Measure DC voltage between LI1/LI2 and COM 
Verify the speed reference is valid: Meaure DC voltage between AI1/AI2 and COM
Verify the drive state and status: ​i.e. RDY state, faulted, or some other state.

Where can I find programming assistance for setting up Ethernet TCP/IP on the ATV61 and ATV71 drives?

Issue:
Setting up Ethernet TCP/IP on the ATV61 and ATV71 drives.

Product Line:
Altivar ATV61 and ATV71

Environment:
All

Cause:
Ethernet TCPIP manual VW3A3310D

Resolution:
You can find ethernet configuration assistance in the ATV61/71 Ethernet TCPIP manual 30072-452-37

When comparing projects with a BMENOC3xx in Unity Dif, what does the “ParamKW” refer to?

UnityDif
If the value of ParamKW is different, then it is referring to any modification done on the configuration of the NOC (most likely in the DTM browser). If you do not see any changes in this section of the program, then no actual modification was done. For example, if the IP address of a device in the DTM browser is changed and then changed back to its original value, a time stamp will still exist, resulting in the ParamKW changing.
DTM

How can you change the maximum speed on the ATV31 or ATV312 drives so that the motor can operate above 60Hz?

Issue:   
How can the motor operate above 60Hz in the ATV31 or ATV312 drives?
 
Product Line:   
ATV31 ATV312
 
Environment:  
All
 
Cause:  
Changing high speed / max frequency
 
Resolution:   
Parameter HSP determines the maximum speed the drive can operate.  Parameter tFr determines the maximum value that HSP can be adjusted.  

By default, tFr is set to 60Hz.  When changing the Motor Frequency - bFr this changes tFr to 72Hz.  

To increase the maximum speed above 72Hz - Go to the drc menu and Set parameter tFr.  This can be adjusted up to 500Hz.  After saving the change, go to the SEt menu > HSP and adjust up to the desired speed.  

If your motor is a specialty motor that is rated for a frequency other than 50Hz. or 60Hz. such as a 300Hz. rated spindle motor, change parameter FrS under the DRC menu to match the rated frequency of the motor.

 

Do the ATV212 and ATV312 drives have output phase loss protection?

Issue:
Output phase loss protection on ATV212 and ATV312 drives

Product Line:
Altivar 212, Altivar 312

Environment:
All models, all serial numbers. 

Cause:
Protection from the loss of an output phase. 

Resolution:
Both the ATV312 and ATV212 have output phase loss protection. 

Output phase protection can be deactivated on both of these drives if needed for testing purposes:
For the ATV312 go to FLT > OPL and change from YES to NO to deactivate phase protection.
For the ATV212, press Mode until you see AUF, then scroll down to F - - - and hit Enter.  Scroll down to F605 and change to '0' to deactivate.

How do I add a password on an ATV312?

Issue:
ATV312 password.

Product Line:
ATV312, Altivar 312

Environment:
All

Cause:
Prevent program changes

Resolution:
You can add a password by setting parameter COd (PIN code 1).  This parameter is under the SUP menu (Monitoring).  Change from Off to to On and then change the display to a 4 digit code and push the Enter button.

To unlock the drive, go under the COd parameter again and enter the pin code saved. 

To reactivate the same pin code, change COd back to On and push the enter button. 

To change the pin code, once unlocked, change the pin code to another 4 digit code and push enter to save. 

To deactivate the pin code, change the display to Off and then push Enter to save.

What is an USF fault on the ATV312 drives?

Issue
USF showing on the ATV312 drives.

Product Line:
Altivar ATV31 and ATV312

Environment:
All

Cause:
Drive is tripping on USF or undervoltage fault.

Resolution:
USF means undervoltage fault.
Get a digital meter and check your input line voltages on L1 L2 L3
ATV312........M2 drive will trip on USF if the line voltage is 160VAC or less
ATV312........M3 drive will trip on USF if the line voltage is 160VAC or less
ATV312........N4 drive will trip on USF if the line voltage is 300VAC or less
ATV312........S6 drive will trip on USF if the line voltage is 430VAC or less

How can I program an ATV312 for PI control?

Issue:
How do I configure the Pressure or PI [PID Regulator] control configuration in the ATV312?


Product Line:
ATV312 ALtivar 312


Environment:
All model numbers


Cause:
Activating PID control


Resolution:
Several factory default functions are incompatible with PI control so they must first be deactivated before PI control can be set up.
First, go to the FUN menu and turn off the Summing and un-assign summing inputs.
From the FUn- menu, SAI submenu, make sure SA2 and SA3 are both set to NO (by default SA2 is set to AI2).
Then go to FUN menu and turn off the Preset Speed function.
Go to FUn- menu,  PSS submenu, set PS4 to NO (default is LI4) and then set PS2 to NO (default is LI3).
You will not be able to set PS2 to No until after PS4 had been changed to No, so be sure to do it in the order listed.

Then you should have access to the PI Submenu.
Set PI parameters:
FUn - PI - PIF = AIx where x is the analog input for the PID feedback - Typically AI3 if the feedback signal is a mA input or AI1 if the signal is DC Voltage.
FUn - PI - PII = YES for internal setpoint adjustment
FUn - PI - rPI = reference setpoint as a % of the feedback full range

Example:  Transducer is a 0-120 PSI sensor and the customer wants to maintain 60 PSI....The rPI parameter would be set to 50% (half of the sensor range.
If the setpoint was 80PSI then the rPI parameter would be set to 67%  (80psi/120psi=.667 or 67%)


Also consider:
FUn - PI - PIC = YES to reverse the PID correction so that a low feedback results in a slower VFD speed to correct
Sleep/Wake function by setting SEt - tLS = low speed timeout and PI - rSL = wake threshold

ATV312 Programming Manual
 

What are the factors to consider in selecting the braking resistor for Altivar drives?

Issue:
What are the things to consider in selecting the braking resistors for Altivar drives?

Product Line:
All Altivar Drives

Environment:
All

Cause:
Needs to know if the factors to consider in selecting the braking resistor for Altivar drives

Resolution:
1.) Resistance - Choosing a too low resistance may damage the drive.  Too high and it's not as effective as a brake.  That's because higher resistance means we will get lower current from the drive.  Lower resistance means higher currents and too high current can damage the braking IGBT in the drive.

2.) Watts - Higher wattage means more durable braking resistor.

Video: How is a faulted Altivar drive reset?

Issue:
Reset a  fault on a Altivar drive.

Product Line:
Altivar ATV variable speed drives

Environment:
All

Cause:
Need to reset a fault status.

Resolution:
There are multiple ways to reset a fault, including a logic input assignment and communication network.  But an easy way to reset a fault is to remove line voltage from L1,L2,L3.  Allow enough time for the display to go completely blank and then wait another 30seconds.  Reapply power.  If the fault appears again, it means that the VFD has re-faulted.

Note: Some faults have to be reset by removing and reapplying line voltage (power-cycling) the drive. Refer to your drive's Programming Manual for a list of faults that require a power cycle to clear. 

The following video demonstrates how to configure a logic input fault reset function on the Altivar 212:

Why is the LCD display screen blank on a Micrologic Power or Harmonic type trip unit on a Powerpact P frame, R frame, or Masterpact circuit breaker?

Issue:
Why is the display blank on the trip unit?

Product Line:
Powerpact P frame, Powerpact R Frame, Masterpact NT, Masterpact NW

Resolution:
The LCD display on a Micrologic P or H trip unit will be blank unless the trip unit is energized.  Energization requires one of the following sets of conditions:
  1. The trip unit is energized by an external 24 Vdc applied to terminals F1-F2 (F1 negative-F2 positive).  See attachment for location of terminals.
  2. The trip unit is energized by an FFTK or HHTK test kit
  3. There is at least 100 V between two phases, AND the load reaches approximately 20% of the breaker's rated current.
  • Note that the display will not power up with primary injection testing unless one of the conditions in bullet 1 above is met.
  • Note that Ammeter trip units do not require external power and the display will come on with sufficient current flow alone.
See the following bulletins for more information on these trip units.
 

Are power factor correction capacitors recommended with Altivar Variable Frequency drives?

Issue:
Power Factor correction capacitors on the Altivar Variable Frequency Drives. 

Product Line:
Altivar Drives

Environment:
All models and serial numbers

Cause:
None

Resolution:
Schneider Electric does not recommend using power factor correction capacitors with variable frequency drives.  Capacitor banks in distribution systems with 6 pulse variable frequency drives may result in undesirable resonant currents.

Video: Does the ATV312 drive come with a remote keypad?

Issue:
Is a remote keypad come with the ATV312 drive as standard?

Product Line:
ATV312

Environment:
All models and serial numbers

Cause:
None

Resolution:
The ATV312 drive does not come with a remote keypad as a standard item.  It must be ordered separately. 
Remote Keypad Display
(IP54) ATV312, ATV12 VW3A1006
(IP65) ATV312, ATV12 VW3A1007
Mounting Kit, VW3A31101
Graphic Display  (used also with ATV61 and ATV71)  VW3A1101

What is the part number of the USB cable used to connect a PC to a drive or soft start when using SoMove?

Issue:
Cable part number to connect a PC to a drive or soft start when using SoMove or Powersuite?

Product Line:
ATV Altivar Drive ATS Altistart Soft starter

Environment:
All current products

Resolution:
TCSMCNAM3M002P:  This cable is a USB to RS485 interface cable to be used with SoMove and Powersuite.
The cable connects to the the ModBus port on the drive and a USB port on a PC. 

cable image
Note: If using this cable with SoMove, then the SoMove software must be installed on your PC prior to plugging this cable into the USB port on the PC. The driver for this cable is now included in the core SoMove software. And it's important that your PC uses this driver as opposed to a driver that Windows would install automatically.

How do you go from 3 wire control to 2 wire control on the ATV312 drives?

Issue:
Looking to go from 3 wire control to 2 wire control on the ATV312 drives.

Product Line:
Altivar ATV31 and ATV312 drives

Environment:
All

Cause:
The drive was programmed for 3 wire control and now they want change it to 2 wire control.

Resolution:
Programming changes
Go In to the IO menu enter.
find TCC enter
If TCC is 3 C change it to 2C for 2 wire control,
Please note this is a special parameter you will need to hold enter for 3 to 4 seconds.


 

What does the Scrolling LEDs mean on the ATV312?

Issue:
Why is the LED scrolling on the ATV312?
 
Product Line:
Altivar 312, Altivar 12
 
Environment:
All serial numbers
 
Cause:
N/A
 
Resolution:
The scrolling LEDs mean the drive is in Local Operation mode.  To switch into Local Programming, push and hold the ESC button for 2s.  Then all three LED's will be flashing at the same time and the programming can be changed.  When programming is finished, push and hold the ESC button again for 2s to enter into Local Operation again. 

To switch back into Remote mode, push and hold the Mode button for 3s.  Note - some programming is reset to factory defaults if you switch between Local and Remote.  The drive is intended to be used for Local or Remote, not Local and Remote

How many digital inputs and relay outputs come on the ATV312 drives?

Issue:
ATV312 digital inputs and relay outputs.

Product Line:
Altivar ATV312

Environment:
All 

Cause:
Digital input and relay outputs are on the drive. 

Resolution:
6 digital inputs    LI1 thru LI6
2 relay outputs   R1 and R2 relays
3 analog inputs   AI1, AI2 and AI3
1 analog output   AO
 

Where can I find Short circuit current ratings (SCCR) information for ATV312 drive?

Issue:
ATV312 Short Circuit Current Ratings (SCCR) information.

Product Line:
Altivar 312

Environment:
All

Cause:
Short circuit protection for drives

Resolution:
Please see attached for information.

Who do I need to contact to get Start- Up Services on an AC Drive or Softstarter?

Issue:
Contact to get Start -Up Services on an AC Drive or Softstarter.

Product Line:
AC Drive or Softstarter

Cause:
N/A

Resolution:
If startup services has already been purchased, contact the project manager at the appropriate distributor or Schneider Electric sales office to schedule the service.
If startup services needs to be ordered, contact an authorized startup technician, searchable at the following link,

https://drivestartup.schneider-electric.us/#/techlocator 

Or you can call DPSG (888-778-2733 option 2, option 4), and we'll be happy to submit a request to have you contacted to set up a visit by our Services department. 

Can you use the Lonworks card from an ATV21 on an ATV212 and vice versa?

Issue:
Usage of a Lonworks card from an ATV21 on an ATV212 and vice versa

Product Line:
Altivar 21, Altivar 212

Environment:
All

Cause:
N/A

Resolution:
No.
The ATV21 drive's lonworks card part number is VW3A21312.
The ATV212 drive's lonworks card part number is VW3A21212.
 

Where is information on ATV31C drive ratings?


Issue:
ATV31C drive ratings

Product Line:
ATV31C

Environment:
All serial numbers for ATV31C

Cause:
N/A

Resolution:
Located in the Installation manual document 1624729.  It is attached.                
 

What is the breakdown of components for 9001KYK117?

Issue:
Breakdown of components for 9001KYK117  

Product Line:
Harmony Push Buttons

Environment:
Harmony Control Stations

Cause:
Product Features

Resolution:
9001KYK117 components are:
1-9001KY1S1 (red enclosure)
1-9001K15 (break glass operator)
1-9001KA1 (1 open and 1 closed contact)
1-9001KN799RP (legend plate)

Replacement glass discs are 9001K57 (package of five)

What is the part # for a clear plastic bezel for a ZB4BW31, ZB4BW32, ZB4BW33 ZB4BW34, ZB4BW35, ZB4BW36, ZB4BW37 ?

Issue:
What is the part # for a clear plastic bezel for a ZB4 illuminated push buttons (incandescent type)?

Product Line:
Push Buttons and Operator Interface

Environment:
ZB4 Illuminated push buttons

Cause:
Product selection

Resolution:
Use a W415595280111

Why does an ATV312 operate the motor in reverse when a run forward command is given?

Issue:
Why did my ATV312 run the motor in reverse when a run forward command is given?

Product Line:
ATV312

Environment:
All models

Cause:
Motor runs backwards

Resolution:
Verify the run forward command:
In two- wire control, LI1 is run forward. 
In three- wire control, LI2 is run forward.
Monitor the logic inputs in Menu SUP > LIA- > LIS. 
If using local or remote keypad command, consider the setting for CtL > rot, Rotating direction and action of the FWD/REV button.

If the correct run command is confirmed, then reverse the phasing to the motor by swapping two of the motor leads at the output of the drive, Terminals U/T1-V/T2-W/T3.
 

Does the ATV312 have a sleep function?

Issue:
ATV312 Sleep function configuration

Product Line:
All ATV312 Drives

Environment:
All model numbers, all serial numbers

Cause:
Sleep function

Resolution:
Yes.
TLS is a low speed time out.  If the drive is maintaining low speed (LSP) for the amount of time you set under TLS (in seconds), then will cause the drive to go to sleep.
It will wake up and run when commanded faster than LSP.

Press Enter (press on the dial) and scroll down (turn the dial clockwise) to SET menu.  
Press Enter and scroll down to TLS parameter.
Press Enter to view current setting and to make changes.  
Press Enter to save changes.

d

 

 

What is the maximum distance the motor can be from the ATV61 and ATV71 drive?


Issue:
is there a maximum distance of the cables connected between the drive and motor?

Product Line:
Altivar ATV61 and ATV71

Environment:
All

Cause:
Application notes on motor cable distance.

Resolution:
Length of motor cables from ATV61


Length of motor cables from ATV71

Length of motor cables from ATV71
Length of motor cables from ATV71

Altivar drive is showing dCb on the display.

Issue:  
What is the error code dCb on the Altivar Drive's display.
 
Product line: 
Altivar drive families: ATV12, ATV28,  ATV312, ATV32, ATV61, ATV71. 
 
Environment: 
All models, all serial numbers.
 
Cause: 
DC Injection Braking.
 
Resolution: 
This is a normal drive state.  It is indicating the drive is injecting DC current into the motor to slow the motor down.  This typically appears on deceleration or at the end of the deceleration ramp.  On some drives, DC Injection can be turned on using a Logic Input. 
 

What is an "NOF" code in the ATV31 or ATV312 last fault?

Issue:
ATV31 showing nOF in the LFT parameter

Product Line:
ATV31/ATV312

Environment:
All
 
Cause:
Troubleshooting

Resolution:
Last fault code  NOF means "No Fault".
This indicates the drive does not have any recorded faults stored in memory.

Can the Altivar ATV312 Drives do single phase 110 VAC input?

Issue:
ATV312 single phase 110 VAC input

Product Line:
ATV312 Drives

Environment:
All serial numbers for ATV312 Drives

Cause:
N/A

Resolution:
No it cannot. The drive can only do 208/230 VAC single-phase on the single phase input rated drives that have the M2 suffix..

What replaces the ATV31 Drive series?

Issue:
ATV31 series replacement

Product Line:
All  ATV31 Except ATV31W......

Environment:
All

Cause:
Obsolete

Resolution:
The ATV31 series was replaced by the ATV312 series, which has been replaced by the ATV320 series. The ATV320 is now available.

Do we have variable speed drives for single-phase motor?

Our variable speed drives are designed to control three-phase motors only.

However if the motor is replaced with a 3 phase 240V motor, a single phase 240V input inverter can be used.
e.g. ATV12 is a single phase inverter for use with three phase 230v motors.

This single phase in to three phase output function is available on the ATV12 and ATV320 drives up to the maximum rating of 2.2kw
 

How is the ATV312 programmed to be controlled via the VW3A1007 remote keypad?

Issue:
Control via the VW3A1007 remote keypad on ATV312.

Product Line:
ATV31 / ATV312

Environment:
All models, All serial numbers

Cause:
Information not available in current literature.

Resolution:
From RDY, navigate to the CTL menu
Set parameter LAC to L3
Set parameter CHCF to SEP
Set parameter FR1 to LCC
Set parameter CD1 to LCC
Cycle power to the drive.
When you first power the drive, before issuing a run command, press enter three times to navigate to the HMI frequency reference menu.  From here you will be able to adjust the speed of the drive up and down using the arrow buttons on the remote keypad.

Is there a phase rotation parameter on the ATV312?

Issue:
Phase rotation parameter on the ATV312 

Product Line:
ATV312

Environment:
All serial numbers, all model numbers.

Cause:
Run forward command results in motor running in reverse rotation.

Resolution:
No, the ATV312 does not have a phase rotation parameter.  Typically, correction of rotation is accomplished by swapping 2 motor leads at the VFD output, T1/T2/T3.
In the CtL menu, there is a Rotating Direction parameter (rot) that applies to the the remote keypad FWD/REV button only when the command channel is LCC and speed reference channel is AIU1 or LCC.

rot parameter
Information about the rot parameter can be found in the ATV312 Programming Manual:
https://www.schneider-electric.us/en/download/document/BBV46385/

Video: How to install the S29313 H and J frame toggle extension

Issue:
How do you install the handle extension on a PowerPacT H frame or J frame molded case circuit breaker?
 
Product Line:
Molded Case Circuit Breakers
 
Resolution:
To install the toggle extension on the H or J frame circuit breaker, you will fit the handle extension over the handle and then screw into place with the provided screw. For further information, see attached instruction bulletin or video below:

What are the part numbers for the RJ45 Modbus cables for Schneider drives and soft starters?

Issue:
RJ45 Modbus cable part numbers for drives and soft starters.

Product Line:
All drives and soft starters.

Environment:
All

Cause:
Modbus connection cables.

Resolution:
3 meter length cable VW3A8306R30
1 meter length cable VW3A8306R10
0.3 meter length cable VW3A8306R03

NOTE:  These cables will not work for connecting a remote mounted keypad for the drives/softstarts.  
The best cables for remote keypad connections are:
VW3A1104R10 - 1 meter long
VW3A1104R30 - 3 meters long
VW3A1104R50 - 5 meters long
VW3A1104R100 - 10 meters long

What size speed potentiometer to use on the Schneider Electric VFDs?

Issue: 
Speed potentiometer size to use on Schneider Electric VFDs.
 
Product Line:
Altivar 61, Altivar 71, Altivar 312, Altivar 12, Altivar 212, Altivar 32, Altivar 58
 
Environment:
All serial numbers
 
Cause:
N/A
 
Resolution:
The Schneider Electric VFDs will work with any potentiometer with a rating from 1k Ohms to 10k Ohms.

What is the padlock attachment for NSX400 breakers?

Issue:
Padllock attachment on a NSX400N

Product Line:
Molded Case Circuit Breakers

Resultion;
The padlock attachment is S32631 for lock on/off or NJPAF for lock off only.

In programming PID, what does parameter FbS do on an ATV312 drive?

Issue:
Parameter FbS (feedback scale factor)

Product Line:
ATV31 and ATV312

Environment:
All models and serial numbers

Cause:
None

Resolution:
The parameter FbS is a parameter that can be used to scale the reference according to the range of the feedback sensor.
Example: Regulating pressure
PI reference range of process, 0-50 psi (0-100%)
Range of pressure sensor, 0-100 psi
FbS = Max sensor range / Max process range
FbS = 100/50 = 2

Is the remote graphic keypad display, VW3A1101, compatible with the ATV312 drive?

Issue:
Can you use VW3A1101 with ATV312 drive?

Product Line:
ATV312

Environment:
All models

Cause:
Display

Resolution:
Yes, the VW3A1101 keypad is compatible with the ATV312 drive.  The keypad must have minimum CPU V1.2IE09.

It is not direct connected to the drive.  At minimum, an adaptor and a cable are required:
VW3A1105 is a female-female adaptor between cable and keypad
VW3A1104R10 is a 1meter cable
VW3A1104R30 is a 3meter cable
VW3A1104R50 is a 5meter cable
VW3A1104R100 is a 10meter cable

An optional remote mount kit, VW3A1102, will include the VW3A1105 adaptor.
An optional door, VW3A1103, adds to the remote mount kit to increase IP54 rating to IP65.

What is the replacement 120 volt coil for a CA2DN131?

Issue:
Is there a 120 volt coil replacement for a CA2DN131?

Product Line:
Relays and Timers

Environment:
Industrial relays

Cause:
Legacy Replacement

Resolution:
This coil is obsolete.  Relay will have to be replaced.  Check the online cross reference for current replacement.  

Where can I find a list of line/load reactors and output filters for Altivar drives?

Issue:
Finding line/load reactors and output filters for Altivar drives.

Product Line:
All drives

Environment:
All

Resolution:
See attached table for opens style units and enclosed Nema 1 units.



 

What would cause the ATV312 display to flash?

Issue:
Drive's display is flashing.

Product Line:
ATV312

Environment:
All 

Cause:
Drive display blinks off and on.  Motor does not reach commanded speed.  Drive may eventually shuts down with Motor Overload Fault (OLF) or Drive Over Temp Fault (OHF).

Resolution:
The blinking or flashing display is a warning indication that the motor is pulling the maximum current limit programmed value in the drive which is set by the CLI [Current Limitation] parameter in the SEt- menu as the image below. 
                        CLI atv312
  • Check your load to see if motor direction is correct. If the motor is spinning too fast in the wrong direction, the drive will have a difficult time catching it and correcting the direction. In this case, a mechanical brake on the motor may be necessary
  • See if motor is stuck or in a locked rotor.
  • Check the drive settings (drC- menu) to be sure the motor nameplate information is entered correctly (UnS, FrS, nCr, nSP, COS) 
  • Check your the Set- menu to be sure ItH (motor thermal current - Overload protection) and CLI (Current limitation) are set properly.
  • Measure motor current draw.

Please note the main display on the drive will flash the frequency hz value on and off when its in current limit mode. 
The remote HMI VW3A1101 will show CLI in the upper left corner of the HMI if its in Current Limit.

See the ATV312 Programming Manual for further details:
https://www.schneider-electric.us/en/download/document/BBV46385/
 

Does the ATV312 have a run time or elapsed time meter?

Issue:
Run time on ATV312

Product Line:
Altivar 312

Environment:
All models

Cause:
None

Resolution:
Yes, parameter rtH (Operating time) in the SUP menu displays the total time that the motor has been powered up.  If desired, this can be set as the default display.  This operating time can be reset to zero by setting rPr = rtH in the FLt menu.

What is the DC bus level at which the Brake resistor engages for the ATV312 Drives?

Issue:
DC bus level at which the Brake resistor engages for the ATV312 drives

Product line:
ATV312, Altivar 312

Environment:
all

Cause:
n/a

Resolution:
The internal transistor will output to a Brake resistor at the following voltage levels:

For 200-240V drives, the DC bus level is 379V
For 380-480V drives, the DC bus level is 792V
For 575V drives, the DC bus level is 948V



 

What is the part number for Line reactors for ATV drives in the Canadian market?

Issue:
Altivar drives line reactor part numbers.

Product Line:
ATV12, ATV312, ATV61, ATV71

Environment:
Canadian Market

Cause:
3% Line reactors.
5% Line reactors.
Dv/Dt Filters

Resolution:
Please see attached sheet.
For ATV31,  use the ATV312 selection sheet.
 

How is the ATV312 default display changed to show a different monitored parameter?

Issue:
Display a different monitored parameter on an ATV312

Product Line:
ATV312  ATV31

Environment:
All

Cause:
Preference is to normally display a parameter such as motor current or motor torque, not the factory default of output frequency.

Resolution:
Go to SUP menu and display the parameter to be used as a default display ( e.g. LCr or Otr ).  Press ENT once to show the current value of that parameter.  Then press and hold ENT for about 2 seconds and the display will flash, indicating the process is complete.

How is the switching frequency changed on an ATV312 drive?

Issue:
Trying to change the switching frequency changed on an ATV31/ATV312 drive.

Product Line:
ATV31 ATV312

Environment:
All models

Cause:
N/A

Resolution:
The switching frequency parameter (SFr) can be found in both the SEt and drC Menus. It is adjustable from 2.0 to 16 kHz.

On the ATV312, what is parameter CL1?

Issue:
 Function for parameter CL1 on an ATV312

Product Line:
ATV312

Environment:
All

Cause:
None

Resolution:
CL1 sets a threshold to limit the current output to the motor.  It is used to limit stress on the motor and load when conditions are abnormal.
Typically this value is set at 1.2 X motor FLA for variable torque loads and at 1.5 X FLA for constant torque loads.

What is the difference between the VW3A3310 and the VW3A3310D Modbus Ethernet TCP/IP option cards?

Issue:
VW3A3310 with a "D" on the end of the part number.

Product Line:
ATV71 and ATV71

Environment:
All models and serial numbers

Cause:
None

Resolution:
The "D" on the end of the VW3A3310D indicates it is equipped for daisy chain and has dual RJ45 connectors.  A network cable can go into one RJ45 and out the other to connect to the next drive in the network.  The VW3A3310 has only one RJ45 port.
Show More