Specifications
Design
Range of product
Range
Product or component type
Product compatibility
Sustainable offer status
Warranty
Physical
[ue] rated operational voltage
Mechanical durability
Protection type
Height
Width
Depth
Net weight
Environmental characteristic
Product certifications
Reach regulation
Reach free of svhc
Eu rohs directive
Toxic heavy metal free
Mercury free
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
California proposition 65
Others
Package 1 bare product quantity
Package 2 bare product quantity
Package 3 bare product quantity
Package 4 bare product quantity
Device short name
Mounting location
Auxiliary contacts operation
Pole contact composition
[ui] rated insulation voltage
[ith] conventional free air thermal current
Minimum switching current
Minimum switching voltage
Rated operational power in va
Rated operational power in w
Tightening torque
Compatibility code
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Unit type of package 3
Number of units in package 3
Package 3 height
Package 3 width
Package 3 length
Package 3 weight
Weee
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
End of Life Manual
-
Installation Instruction
-
Technical Drawing
-
Certificates (MSDS)
-
Declaration of Conformity
-
eTechPub
Frequently Asked Questions
hide showGV2ME, GV2P, GV2L, GV2LE, GV3P and GV3L motor protection circuit breakers (MPCB) can be fitted with the following fault indicating contact blocks:
GVAD0110
GVAD0101
GVAD1010
GVAD1001
These blocks comprise of fault signalling contacts and instantaneous auxiliary contacts.
GVAD0110
A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs.
A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energised and open when the device is de-energised.
GVAD0101
A N/C fault signalling contact (terminals 95-96), closed if there is no fault, open when a fault (magnetic or thermal) occurs.
A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energised and open when the device is energised.
GVAD1010
A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs.
A N/O instantaneous auxiliary contact (terminals 53-54), closed when the device is energised and open when the device is de-energised.
GVAD1001
A N/O fault signalling contact (terminals 97-98), open if there is no fault, closed when a fault (magnetic or thermal) occurs.
A N/C instantaneous auxiliary contact (terminals 51-52), closed when the device is de-energised and open when the device is energised.
The instantaneous auxiliary contact test is performed by creating a state of transition of the handle actuator between the de-energised position and the energised position.
The fault contact test is performed by pressing the test button when the handle actuator is in the closed position.