TeSys D, Star Delta Starter, TeSys Deca, 3 x 3P (3 NO), 18A, 240VAC 50/60Hz coil

Home ProductsIndustrialTeSysStar Delta Starter

TeSys D, Star Delta Starter, TeSys Deca, 3 x 3P (3 NO), 18A, 240VAC 50/60Hz coil

Item Number: LC3D18AU7

Datasheet

Product Dimensions

Width icon

Width144 mm

Height icon

Height124 mm

Depth icon

Depth143 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys Deca

Range

TeSys|TeSys Deca

Product or component type

star delta starter

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Device presentation

pre-wired

[ue] rated operational voltage

power circuit: <= 690 V AC 25...400 Hz

[ie] rated operational current

18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

Electrical durability

1.65 Mcycles 18 A AC-3 at Ue <= 440 V

Provided equipment

protective cover

Mounting support

plate

Standards

EN 60947-4-1|CSA C22.2 No 14|IEC 60947-4-1|UL 508|EN 60947-5-1|IEC 60947-5-1|IEC 60335-1

Product certifications

CSA|RINA|GOST|DNV|GL|LROS (Lloyds register of shipping)|CCC|BV|UL

Connections - terminals

control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end|control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end|control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end|control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end|control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end|control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end|power circuit: screw clamp terminals 1 1.5-6 mm² - cable stiffness: flexible without cable end|power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible without cable end|power circuit: screw clamp terminals 1 1-6 mm² - cable stiffness: flexible with cable end|power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible with cable end|power circuit: screw clamp terminals 1 1.5-6 mm² - cable stiffness: solid without cable end|power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: solid without cable end

Width

144 mm

Height

124 mm

Depth

143 mm

Net weight

1.73 kg

Insulation resistance

> 10 MOhm for signalling circuit

Ip degree of protection

IP20 front face conforming to IEC 60529

Climatic withstand

conforming to IACS E10| conforming to IEC 60947-1 Annex Q category D

Ambient air temperature for storage

-60...80 °C

Ambient air temperature for operation

-40...70 °C at Uc

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental disclosure

ENVPEP1501004

Circularity profile

ENVEOLI1501004

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Package 1 bare product quantity

1

Product name

TeSys Deca

Device short name

LC3D

Contactor application

motor control

Utilisation category

AC-3

Poles description

3 x 3P

Pole contact composition

3 x 3 NO

Motor power kw

11 kW at 220/230 V AC 50/60 Hz|22 kW at 415 V AC 50/60 Hz|22 kW at 440 V AC 50/60 Hz|18.5 kW at 380/400 V AC 50/60 Hz

Control circuit type

AC at 50/60 Hz

[uc] control circuit voltage

240 V AC 50/60 Hz

Auxiliary contact composition

1 NC for KM1 star contactor

[uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

Overvoltage category

III

[ui] rated insulation voltage

power circuit: 690 V conforming to IEC 60947-4-1|power circuit: 600 V CSA certified|power circuit: 600 V UL certified|signalling circuit: 690 V conforming to IEC 60947-1|signalling circuit: 600 V CSA certified|signalling circuit: 600 V UL certified

Interlocking type

mechanical

Tightening torque

power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm|power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2|control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm|control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2|power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2|control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Maximum operating rate

30 cyc/h 60 °C

Starting time

30 s

Coil technology

without built-in suppressor module

Control circuit voltage limits

drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C)|operational: 0.8...1.1 Uc at 50 Hz (at <60 °C)|operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)

Inrush power in va

70 VA 60 Hz cos phi 0.75 (at 20 °C)|70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in va

7.5...7.5 VA 60 Hz cos phi 0.3 (at 20 °C)|7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation

2...3 W at 50/60 Hz

Auxiliary contacts type

mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC|mirror contact conforming to IEC 60947-4-1 3 x 1 NC

Signalling circuit frequency

25...400 Hz

Minimum switching current

5 mA for signalling circuit

Switching voltage

17 V for signalling circuit

Non-overlap time

1.5 ms on de-energisation between NC and NO contact|1.5 ms on energisation between NC and NO contact

Power range

1.1...2 kW at 100...120 V 3 phases|4...6 kW at 200...240 V 3 phases|7...11 kW at 380...440 V 3 phases|7...11 kW at 480...500 V 3 phases|7...11 kW at 525...690 V 3 phases

Motor starter type

star delta starter

Protective treatment

TH conforming to IEC 60068-2-30

Pollution degree

3

Operating altitude

3000 m without derating

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Mechanical robustness

vibrations contactor open: 2 Gn, 5...300 Hz|vibrations contactor closed: 4 Gn, 5...300 Hz|shocks contactor open: 10 Gn for 11 ms|shocks contactor closed: 15 Gn for 11 ms

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

17.5 cm

Package 1 width

15.7 cm

Package 1 length

23.0 cm

Package 1 weight

1.721 kg

Unit type of package 2

S06

Number of units in package 2

27

Package 2 height

73.5 cm

Package 2 width

60.0 cm

Package 2 length

80.0 cm

Package 2 weight

59.467 kg