TeSys GV4, Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, Everlink terminals

Home ProductsIndustrialTeSysMotor circuit breaker

TeSys GV4, Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, Everlink terminals

Item Number: GV4PE02N

Datasheet

Product Dimensions

Width icon

Width81 mm

Height icon

Height155 mm

Depth icon

Depth116 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys Deca

Range of product

TeSys GV4

Product or component type

motor circuit breaker

Device application

motor protection

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Control type

toggle

[in] rated current

2 A

[ue] rated operational voltage

690 V AC 50/60 Hz conforming to IEC 60947-2

Mechanical durability

40000 cycles

Electrical durability

40000 cycles for AC-3 at 440 V In/2|40000 cycles for AC-3 at 440 V In

Connections - terminals

EverLink BTR screw connectors (top) 1 cable(s) 1.5-70 mm² - solid|EverLink BTR screw connectors (top) 1 cable(s) 1.5-50 mm² - flexible|EverLink BTR screw connectors (bottom) 1 cable(s) 2.5-95 mm² - solid|EverLink BTR screw connectors (bottom) 1 cable(s) 2.5-70 mm² - flexible

Height

155 mm

Width

81 mm

Depth

116 mm

Net weight

1.45 kg

Standards

CSA C22.2 No 60947-4-1|UL 60947-4-1|EN/IEC 60947-4-1|EN/IEC 60947-2

Product certifications

IEC|UL|CSA|CCC|EAC|ATEX|EU-RO MR

Climatic withstand

conforming to IACS E10

Ik degree of protection

IK07 conforming to IEC 62262

Ip degree of protection

IP40 conforming to IEC 60529

Ambient air temperature for storage

-50...85 °C

Ambient air temperature for operation

-25...70 °C

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP1704004EN

Circularity profile

ENVEOLI1704004EN

Others

Life cycle assessment data

Yes

Substance regulation data deliverable

Yes

Package 1 bare product quantity

1

Device short name

GV4PE

Product name

TeSys GV4|TeSys Deca

Trip unit technology

electronic|thermal-magnetic

Poles description

3P

Utilisation category

category A conforming to IEC 60947-2|AC-3 conforming to IEC 60947-4-1

Operating position

any position

Motor power kw

0.25...0.25 kW at 400...415 V AC 50/60 Hz|0.37...0.37 kW at 400...415 V AC 50/60 Hz|0.55...0.55 kW at 400...415 V AC 50/60 Hz|0.75...0.75 kW at 400...415 V AC 50/60 Hz|0.37...0.37 kW at 500 V AC 50/60 Hz|0.55...0.55 kW at 500 V AC 50/60 Hz|0.75...0.75 kW at 500 V AC 50/60 Hz|1.1.1 kW at 500 V AC 50/60 Hz|0.55...0.55 kW at 660...690 V AC 50/60 Hz|0.75...0.75 kW at 660...690 V AC 50/60 Hz|1.1.1 kW at 660...690 V AC 50/60 Hz|1.5...1.5 kW at 660...690 V AC 50/60 Hz

Breaking capacity

100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2|50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2|50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2|15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2|65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947|65 kA at 240 V AC 50/60 Hz conforming to UL 60947|35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947|8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2|25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2|18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947

Magnetic tripping current

34 A

[ui] rated insulation voltage

800 V AC 50/60 Hz conforming to IEC 60947-2

[ith] conventional free air thermal current

115 A conforming to IEC 60947-4-1

[uimp] rated impulse withstand voltage

8 kV conforming to IEC 60947-2

Power dissipation per pole

4.6 W

Maximum operating rate

25 cyc/h

Rated duty

continuous conforming to IEC 60947-4-1

Direct connector

without

Tightening torque

9 N.m for cable 16-95 mm²|5 N.m for cable 1.5-10 mm²

Mechanical robustness

vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6|vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6|shocks: 15 gn 11 ms conforming to IEC 60068-2-27

Phase failure sensitivity

yes conforming to IEC 60947-4-1

Suitability for isolation

yes conforming to IEC 60947-1

Pollution degree

3

Fire resistance

960 °C conforming to IEC 60695-2-11

Operating altitude

5000 m

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

17.0 cm

Package 1 width

11.0 cm

Package 1 length

22.0 cm

Package 1 weight

1.72 kg

Unit type of package 2

S03

Number of units in package 2

5

Package 2 height

30.0 cm

Package 2 width

30.0 cm

Package 2 length

40.0 cm

Package 2 weight

14.0 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Pvc free

Yes

Halogen content performance

Halogen free plastic parts product
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Operating Manuals

  • Certificates (MSDS)

  • Declaration of Conformity

  • eTechPub