TeSys D Contactor
Item Number: LC1D09BD
Datasheet

For LC1D09BD
Barcode
Qty | UoM | EAN | Colour |
---|---|---|---|
1 | 3389110353075 | - | |
- | |||
- |
Barcode
Qty | UoM | EAN | Colour |
---|---|---|---|
1 | 3389110353075 | - |
Specifications
Design
Range of product
Product or component type
Warranty
Physical
[ue] rated operational voltage
- power circuit: <= 690 V AC 25...400 Hz
- power circuit: <= 300 V DC
[ie] rated operational current
- 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
- 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
- 9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Mechanical durability
Electrical durability
- 0.6 Mcycles 25 A AC-1 at Ue <= 440 V
- 2 Mcycles 9 A AC-3 at Ue <= 440 V
- 2 Mcycles 9 A AC-3e at Ue <= 440 V
Connections - terminals
- power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
- power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
- power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
- power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
- power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
- power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
- control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
- control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
Insulation resistance
Mounting support
- plate
- rail
Standards
- CSA C22.2 No 14
- EN 60947-4-1
- EN 60947-5-1
- IEC 60947-4-1
- IEC 60947-5-1
- UL 60947-4-1
- IEC 60335-1:Clause 30.2
- IEC 60335-2-40:Annex JJ
- UL 60335-2-40:Annex JJ
- CSA C22.2 No 60947-4-1
Product certifications
- UL
- CCC
- CSA
- Marine
- UKCA
- EAC
- CB Scheme
Ip degree of protection
Climatic withstand
- conforming to IACS E10 exposure to damp heat
- conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Height
Width
Depth
Net weight
Reach regulation
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
California proposition 65
Others
Life cycle assessment data
Substance regulation data deliverable
Package 3 bare product quantity
Package 2 bare product quantity
Package 1 bare product quantity
Device short name
Contactor application
- motor control
- resistive load
Utilisation category
- AC-4
- AC-1
- AC-3
- AC-3e
Poles description
[uc] control circuit voltage
Motor power kw
- 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
- 4 kW at 380...400 V AC 50/60 Hz (AC-3)
- 4 kW at 415...440 V AC 50/60 Hz (AC-3)
- 5.5 kW at 500 V AC 50/60 Hz (AC-3)
- 5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
- 2.2 kW at 400 V AC 50/60 Hz (AC-4)
- 2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
- 4 kW at 380...400 V AC 50/60 Hz (AC-3e)
- 4 kW at 415...440 V AC 50/60 Hz (AC-3e)
- 5.5 kW at 500 V AC 50/60 Hz (AC-3e)
- 5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
Motor power hp
- 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
- 2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
- 2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
- 5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
- 7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
- 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Compatibility code
Pole contact composition
Protective cover
[ith] conventional free air thermal current
- 25 A (at 60 °C) for power circuit
- 10 A (at 60 °C) for signalling circuit
Irms rated making capacity
- 250 A at 440 V for power circuit conforming to IEC 60947
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity
[icw] rated short-time withstand current
- 105 A 40 °C - 10 s for power circuit
- 210 A 40 °C - 1 s for power circuit
- 30 A 40 °C - 10 min for power circuit
- 61 A 40 °C - 1 min for power circuit
- 100 A - 1 s for signalling circuit
- 120 A - 500 ms for signalling circuit
- 140 A - 100 ms for signalling circuit
Associated fuse rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1
- 25 A gG at <= 690 V coordination type 1 for power circuit
- 20 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
Power dissipation per pole
- 1.56 W AC-1
- 0.2 W AC-3
- 0.2 W AC-3e
[ui] rated insulation voltage
- power circuit: 690 V conforming to IEC 60947-4-1
- power circuit: 600 V CSA certified
- power circuit: 600 V UL certified
- signalling circuit: 690 V conforming to IEC 60947-1
- signalling circuit: 600 V CSA certified
- signalling circuit: 600 V UL certified
Overvoltage category
Pollution degree
[uimp] rated impulse withstand voltage
Safety reliability level
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Control circuit type
Coil technology
Control circuit voltage limits
- 0.1...0.25 Uc (-40-70 °C):drop-out DC
- 0.7...1.25 Uc (-40-60 °C):operational DC
- 1...1.25 Uc (60-70 °C):operational DC
Inrush power in w
Hold-in power consumption in w
Operating time
- 63 ±15 % ms closing
- 20 ±20 % ms opening
Time constant
Maximum operating rate
Tightening torque
- power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
- power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Auxiliary contact composition
Auxiliary contacts type
- type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
- type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency
Minimum switching voltage
Minimum switching current
Non-overlap time
- 1.5 ms on de-energisation between NC and NO contact
- 1.5 ms on energisation between NC and NO contact
Contact compatibility
Protective treatment
Permissible ambient air temperature around the device
- -40...60 °C
- 60...70 °C with derating
Operating altitude
Fire resistance
Flame retardance
Mechanical robustness
- vibrations contactor open (2 Gn, 5...300 Hz)
- vibrations contactor closed (4 Gn, 5...300 Hz)
- shocks contactor open (10 Gn for 11 ms)
- shocks contactor closed (15 Gn for 11 ms)
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Unit type of package 3
Number of units in package 3
Package 3 height
Package 3 width
Package 3 length
Package 3 weight
Packaging made with recycled cardboard
Packaging without single use plastic
Green premium status for reporting
Scip number
Sustainable packaging
Pvc free
Pvc free
F-gas usage performance
Take-back
Take-back
Product contributes to saved and avoided emissions
Removable battery
Carbon footprint (kg.eq.co2 per cr, total life cycle)
Global warming ; total life cycle
Minimum percentage of recycled plastic content
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Data Bulletin
-
End of Life Manual
-
Environmental Disclosure
-
Installation Instruction
-
Technical illustration
-
Technical Drawing
-
Certificates (MSDS)
-
Declaration of Conformity
-
eTechPub
UKCA Declaration TeSysD_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-2
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0
EU Declaration TeSys D_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-25
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0

BU_AUT_664_EPDS_V1_EN - POC for TeSys Motor Control
VERSION
2.0
DATE
25 Oct 2024
REVISION
2.0
TeSys_3P CONT 9A AC3 4KW 1NO 1NC 24VDC COIL - 3D CAD
VERSION
1.0
DATE
11 Jan 2024
REVISION
1.0
LC1D09BD_CAD_DOC
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor, 9-18a, 3 Pole, D-Line (TESYS)
VERSION
1.2
DATE
29 Sep 2023
REVISION
1.2
TeSys - Catalog 2025 - Innovative and connected solutions for motor starters
VERSION
16.0
DATE
11 Mar 2025
REVISION
16.0
Catalog Safety chain solutions & Safety functions English 07/2020
VERSION
2.1
DATE
08 May 2024
REVISION
2.1
Motor Control Solutions for the North American Market Data Bulletin
VERSION
5.0
DATE
10 Mar 2025
REVISION
5.0
TeSys Deca 3-pole contactor 09A DC
VERSION
3.0
DATE
26 Dec 2024
REVISION
3.0
TeSys Deca 3-pole contactor 09A DC
VERSION
3.0
DATE
26 Dec 2024
REVISION
3.0
LC1D 9 to 38 A AC/DC contactors with screw clamp terminals - Instruction Sheet
VERSION
4.1
DATE
14 Jun 2024
REVISION
4.1
TeSys CONTACTOR - TI
VERSION
1.0
DATE
24 Dec 2024
REVISION
1.0
LC1D09BD_2DSalesDrawing_PDF
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
Technical drawing for IEC Contactor, 9-18a, 3 Pole, D-Line (TESYS)
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor 9-18A 3P D-Line TESYS Technical drawings
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor 9-12A 3P D-Line Technical drawings
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
Technical drawing for IEC Contactor, 9-12A, 3 Pole, D-Line
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0

CCC Certificate_TeSys Deca_LC1D09-18&LC2D09-18_SSAP
VERSION
1.0
DATE
01 Apr 2025
REVISION
1.0

CCC_TeSys Deca_LC1D09-18&LC2D09-18_Le Vaudreuil
VERSION
1.0
DATE
01 Apr 2025
REVISION
1.0

CB Certificate TeSys Deca _LC1D09-18&LC2D09-18_Le Vaudreuil
VERSION
1.0
DATE
31 Mar 2025
REVISION
1.0
CCC_TeSys Deca_LC1D09-18&LC2D09-18_SEMW
VERSION
1.0
DATE
16 Dec 2024
REVISION
1.0

CCC_TeSys Deca_LC1D09-18&LC2D09-18_Hyderabad
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0

CB Certificate_ TeSys Deca_LC.D09-18_SSAP
VERSION
1.0
DATE
05 Dec 2024
REVISION
1.0

CB Certificate_TeSys Deca_ LC.D09-18_SEMW
VERSION
1.0
DATE
05 Dec 2024
REVISION
1.0
CSA Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE
VERSION
1.0
DATE
15 Sep 2024
REVISION
1.0
DNV Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
EU RO MR Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
UL_Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE_DC_Coils
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
CSA Certificate_TeSys GV2ME&GV2RT&GV2P&GV2MC&GV2MP and GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
29 Feb 2024
REVISION
1.0
Zelio Relay, Certificate, UL
VERSION
1.0
DATE
23 Feb 2024
REVISION
1.0
UL_Certificate_TeSys GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
22 Dec 2022
REVISION
1.0
CB Certificate TeSys D - LC1D09-18&LC2D09-18_Batam plant
VERSION
1.0
DATE
06 Oct 2022
REVISION
1.0
UKCA Declaration TeSysD_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-2
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0
EU Declaration TeSys D_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-25
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0

BU_AUT_664_EPDS_V1_EN - POC for TeSys Motor Control
VERSION
2.0
DATE
25 Oct 2024
REVISION
2.0
TeSys_3P CONT 9A AC3 4KW 1NO 1NC 24VDC COIL - 3D CAD
VERSION
1.0
DATE
11 Jan 2024
REVISION
1.0
LC1D09BD_CAD_DOC
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor, 9-18a, 3 Pole, D-Line (TESYS)
VERSION
1.2
DATE
29 Sep 2023
REVISION
1.2
TeSys - Catalog 2025 - Innovative and connected solutions for motor starters
VERSION
16.0
DATE
11 Mar 2025
REVISION
16.0
Catalog Safety chain solutions & Safety functions English 07/2020
VERSION
2.1
DATE
08 May 2024
REVISION
2.1
Motor Control Solutions for the North American Market Data Bulletin
VERSION
5.0
DATE
10 Mar 2025
REVISION
5.0
TeSys Deca 3-pole contactor 09A DC
VERSION
3.0
DATE
26 Dec 2024
REVISION
3.0
TeSys Deca 3-pole contactor 09A DC
VERSION
3.0
DATE
26 Dec 2024
REVISION
3.0
LC1D 9 to 38 A AC/DC contactors with screw clamp terminals - Instruction Sheet
VERSION
4.1
DATE
14 Jun 2024
REVISION
4.1
TeSys CONTACTOR - TI
VERSION
1.0
DATE
24 Dec 2024
REVISION
1.0
LC1D09BD_2DSalesDrawing_PDF
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
Technical drawing for IEC Contactor, 9-18a, 3 Pole, D-Line (TESYS)
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor 9-18A 3P D-Line TESYS Technical drawings
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor 9-12A 3P D-Line Technical drawings
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
Technical drawing for IEC Contactor, 9-12A, 3 Pole, D-Line
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0

CCC Certificate_TeSys Deca_LC1D09-18&LC2D09-18_SSAP
VERSION
1.0
DATE
01 Apr 2025
REVISION
1.0

CCC_TeSys Deca_LC1D09-18&LC2D09-18_Le Vaudreuil
VERSION
1.0
DATE
01 Apr 2025
REVISION
1.0

CB Certificate TeSys Deca _LC1D09-18&LC2D09-18_Le Vaudreuil
VERSION
1.0
DATE
31 Mar 2025
REVISION
1.0
CCC_TeSys Deca_LC1D09-18&LC2D09-18_SEMW
VERSION
1.0
DATE
16 Dec 2024
REVISION
1.0

CCC_TeSys Deca_LC1D09-18&LC2D09-18_Hyderabad
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0

CB Certificate_ TeSys Deca_LC.D09-18_SSAP
VERSION
1.0
DATE
05 Dec 2024
REVISION
1.0

CB Certificate_TeSys Deca_ LC.D09-18_SEMW
VERSION
1.0
DATE
05 Dec 2024
REVISION
1.0
CSA Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE
VERSION
1.0
DATE
15 Sep 2024
REVISION
1.0
DNV Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
EU RO MR Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
UL_Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE_DC_Coils
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
CSA Certificate_TeSys GV2ME&GV2RT&GV2P&GV2MC&GV2MP and GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
29 Feb 2024
REVISION
1.0
Zelio Relay, Certificate, UL
VERSION
1.0
DATE
23 Feb 2024
REVISION
1.0
UL_Certificate_TeSys GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
22 Dec 2022
REVISION
1.0
CB Certificate TeSys D - LC1D09-18&LC2D09-18_Batam plant
VERSION
1.0
DATE
06 Oct 2022
REVISION
1.0
UKCA Declaration TeSysD_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-2
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0
EU Declaration TeSys D_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-25
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0

BU_AUT_664_EPDS_V1_EN - POC for TeSys Motor Control
VERSION
2.0
DATE
25 Oct 2024
REVISION
2.0
- Page 1 / 6
- Page 2 / 6
- Page 3 / 6
- Page 4 / 6
- Page 5 / 6
- Page 6 / 6
TeSys_3P CONT 9A AC3 4KW 1NO 1NC 24VDC COIL - 3D CAD
VERSION
1.0
DATE
11 Jan 2024
REVISION
1.0
LC1D09BD_CAD_DOC
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor, 9-18a, 3 Pole, D-Line (TESYS)
VERSION
1.2
DATE
29 Sep 2023
REVISION
1.2
LC1D09BD_2DSalesDrawing_PDF
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
Technical drawing for IEC Contactor, 9-18a, 3 Pole, D-Line (TESYS)
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor 9-18A 3P D-Line TESYS Technical drawings
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
IEC Contactor 9-12A 3P D-Line Technical drawings
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
Technical drawing for IEC Contactor, 9-12A, 3 Pole, D-Line
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0

CCC Certificate_TeSys Deca_LC1D09-18&LC2D09-18_SSAP
VERSION
1.0
DATE
01 Apr 2025
REVISION
1.0

CCC_TeSys Deca_LC1D09-18&LC2D09-18_Le Vaudreuil
VERSION
1.0
DATE
01 Apr 2025
REVISION
1.0

CB Certificate TeSys Deca _LC1D09-18&LC2D09-18_Le Vaudreuil
VERSION
1.0
DATE
31 Mar 2025
REVISION
1.0
CCC_TeSys Deca_LC1D09-18&LC2D09-18_SEMW
VERSION
1.0
DATE
16 Dec 2024
REVISION
1.0

CCC_TeSys Deca_LC1D09-18&LC2D09-18_Hyderabad
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0

CB Certificate_ TeSys Deca_LC.D09-18_SSAP
VERSION
1.0
DATE
05 Dec 2024
REVISION
1.0

CB Certificate_TeSys Deca_ LC.D09-18_SEMW
VERSION
1.0
DATE
05 Dec 2024
REVISION
1.0
CSA Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE
VERSION
1.0
DATE
15 Sep 2024
REVISION
1.0
DNV Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
EU RO MR Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
UL_Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE_DC_Coils
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
CSA Certificate_TeSys GV2ME&GV2RT&GV2P&GV2MC&GV2MP and GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
29 Feb 2024
REVISION
1.0
Zelio Relay, Certificate, UL
VERSION
1.0
DATE
23 Feb 2024
REVISION
1.0
UL_Certificate_TeSys GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
22 Dec 2022
REVISION
1.0
CB Certificate TeSys D - LC1D09-18&LC2D09-18_Batam plant
VERSION
1.0
DATE
06 Oct 2022
REVISION
1.0
UKCA Declaration TeSysD_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-2
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0
EU Declaration TeSys D_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-25
VERSION
1.0
DATE
13 Dec 2024
REVISION
1.0
Frequently Asked Questions
What is the difference between the LAD4TB and LAD4TBDL bi-directional peak limiting diode?
Hide ShowIdentifying the difference between LAD4TB and LAD4TBDL
Product Line:
IEC contactors and starters
Environment:
Products sold and used in the United States
Cause:
Identifying the difference between two similar part numbers
Resolution:
The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.
Related products

DISCONTINUED
GV2ME14
TeSys GV2, Motor circuit breaker, TeSys Deca, 3P, 6 to 10A, thermal magnetic, screw clamp terminals, button control
TeSys Deca, 3P, 6 to 10A, thermal magnetic, screw clamp terminals, button control

DISCONTINUED
GV2LE14
TeSys GV2, Motor circuit breaker, TeSys Deca,3P,10A,magnetic,toggle control,screw clamp terminals
TeSys Deca,3P,10A,magnetic,toggle control,screw clamp terminals
Recently viewed

DISCONTINUED
LC1D09BD
TeSys D, Contactor, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 9A, 24VDC coil