TeSys D, Contactor, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VDC coil

TeSys D, Contactor, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 25A, 24VDC coil

Item Number: LC1D25BD

Datasheet

Product Dimensions

Width icon

Width45 mm

Height icon

Height85 mm

Depth icon

Depth101 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys Deca

Product or component type

contactor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

[ue] rated operational voltage

power circuit: <= 690 V AC 25...400 Hz|power circuit: <= 300 V DC

[ie] rated operational current

25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit|40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit|25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

Mechanical durability

30 Mcycles

Electrical durability

1.65 Mcycles 25 A AC-3 at Ue <= 440 V|1.4 Mcycles 40 A AC-1 at Ue <= 440 V|1.65 Mcycles 25 A AC-3e at Ue <= 440 V

Connections - terminals

control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end|control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end|control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end|control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end|control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end|control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end|power circuit: screw clamp terminals 1 2.5-10 mm² - cable stiffness: flexible without cable end|power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: flexible without cable end|power circuit: screw clamp terminals 1 1-10 mm² - cable stiffness: flexible with cable end|power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible with cable end|power circuit: screw clamp terminals 1 1.5-10 mm² - cable stiffness: solid without cable end|power circuit: screw clamp terminals 2 2.5-10 mm² - cable stiffness: solid without cable end

Insulation resistance

> 10 MOhm for signalling circuit

Mounting support

plate|rail

Standards

CSA C22.2 No 14|EN 60947-4-1|EN 60947-5-1|IEC 60947-4-1|IEC 60947-5-1|UL 60947-4-1|IEC 60335-1:Clause 30.2|IEC 60335-2-40:Annex JJ|UL 60335-2-40:Annex JJ|CSA C22.2 No 60947-4-1

Product certifications

UL|CCC|CSA|Marine|UKCA|EAC|CB Scheme

Ip degree of protection

IP20 front face conforming to IEC 60529

Climatic withstand

conforming to IACS E10 exposure to damp heat| conforming to IEC 60947-1 Annex Q category D exposure to damp heat

Height

85 mm

Width

45 mm

Depth

101 mm

Net weight

0.53 kg

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP110230EN

Circularity profile

ENVEOLI1102030EN

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Life cycle assessment data

Yes

Substance regulation data deliverable

Yes

Package 1 bare product quantity

1

Package 2 bare product quantity

15

Package 3 bare product quantity

240

Device short name

LC1D

Contactor application

motor control|resistive load

Utilisation category

AC-4|AC-3|AC-1|AC-3e

Poles description

3P

[uc] control circuit voltage

24 V DC

Motor power kw

5.5 kW at 220...230 V AC 50/60 Hz (AC-3)|11 kW at 380...400 V AC 50/60 Hz (AC-3)|11 kW at 415...440 V AC 50/60 Hz (AC-3)|15 kW at 500 V AC 50/60 Hz (AC-3)|15 kW at 660...690 V AC 50/60 Hz (AC-3)|5.5 kW at 400 V AC 50/60 Hz (AC-4)|5.5 kW at 220...230 V AC 50/60 Hz (AC-3e)|11 kW at 380...400 V AC 50/60 Hz (AC-3e)|11 kW at 415...440 V AC 50/60 Hz (AC-3e)|15 kW at 500 V AC 50/60 Hz (AC-3e)|15 kW at 660...690 V AC 50/60 Hz (AC-3e)

Motor power hp

3 hp at 230/240 V AC 50/60 Hz for 1 phase motors|2 hp at 115 V AC 50/60 Hz for 1 phase motors|7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors|15 hp at 460/480 V AC 50/60 Hz for 3 phases motors|20 hp at 575/600 V AC 50/60 Hz for 3 phases motors|7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors

Compatibility code

LC1D

Pole contact composition

3 NO

Protective cover

with

[ith] conventional free air thermal current

10 A (at 60 °C) for signalling circuit|40 A (at 60 °C) for power circuit

Irms rated making capacity

140 A AC for signalling circuit conforming to IEC 60947-5-1|250 A DC for signalling circuit conforming to IEC 60947-5-1|450 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity

450 A at 440 V for power circuit conforming to IEC 60947

[icw] rated short-time withstand current

240 A 40 °C - 10 s for power circuit|380 A 40 °C - 1 s for power circuit|50 A 40 °C - 10 min for power circuit|120 A 40 °C - 1 min for power circuit|100 A - 1 s for signalling circuit|120 A - 500 ms for signalling circuit|140 A - 100 ms for signalling circuit

Associated fuse rating

10 A gG for signalling circuit conforming to IEC 60947-5-1|63 A gG at <= 690 V coordination type 1 for power circuit|40 A gG at <= 690 V coordination type 2 for power circuit

Average impedance

2 mOhm - Ith 40 A 50 Hz for power circuit

Power dissipation per pole

3.2 W AC-1|1.25 W AC-3|1.25 W AC-3e

[ui] rated insulation voltage

power circuit: 690 V conforming to IEC 60947-4-1|power circuit: 600 V CSA certified|power circuit: 600 V UL certified|signalling circuit: 690 V conforming to IEC 60947-1|signalling circuit: 600 V CSA certified|signalling circuit: 600 V UL certified

Overvoltage category

III

Pollution degree

3

[uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

Safety reliability level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1|B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Control circuit type

DC standard

Coil technology

built-in bidirectional peak limiting diode suppressor

Control circuit voltage limits

0.1...0.25 Uc (-40-70 °C):drop-out DC|0.7...1.25 Uc (-40-60 °C):operational DC|1...1.25 Uc (60-70 °C):operational DC

Inrush power in w

5.4...5.4 W (at 20 °C)

Hold-in power consumption in w

5.4...5.4 W at 20 °C

Operating time

63 ±15 % ms closing|20 ±20 % ms opening

Time constant

28 ms

Maximum operating rate

3600 cyc/h 60 °C

Maximum operating rate

3600 cyc/h at 60 °C

Tightening torque

control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm|control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2|power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm|power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2|control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2|power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Auxiliary contact composition

1 NO + 1 NC

Auxiliary contacts type

type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1| type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency

25...400 Hz

Minimum switching voltage

17 V for signalling circuit

Minimum switching current

5 mA for signalling circuit

Non-overlap time

1.5 ms on de-energisation between NC and NO contact|1.5 ms on energisation between NC and NO contact

Contact compatibility

M4

Protective treatment

TH conforming to IEC 60068-2-30

Permissible ambient air temperature around the device

-40...60 °C|60...70 °C with derating

Operating altitude

0...3000 m

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Mechanical robustness

vibrations contactor open (2 Gn, 5...300 Hz) |vibrations contactor closed (4 Gn, 5...300 Hz) |shocks contactor closed (15 Gn for 11 ms) |shocks contactor open (8 Gn for 11 ms)

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

5.000 cm

Package 1 width

9.300 cm

Package 1 length

11.300 cm

Package 1 weight

586.000 g

Unit type of package 2

S02

Number of units in package 2

15

Package 2 height

15.000 cm

Package 2 width

30.000 cm

Package 2 length

40.000 cm

Package 2 weight

9.034 kg

Unit type of package 3

P06

Number of units in package 3

240

Package 3 height

75.000 cm

Package 3 width

60.000 cm

Package 3 length

80.000 cm

Package 3 weight

152.000 kg

Sustainable packaging

Yes

Pvc free

Yes
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Environmental Disclosure

  • End of Life Manual

  • Data Bulletin

  • Technical Drawing

  • Certificates (MSDS)

  • Declaration of Conformity

  • eTechPub

Frequently Asked Questions

hide show

What is the difference between the LAD4TB and LAD4TBDL bi-directional peak limiting diode?

Issue:
Identifying the difference between LAD4TB and LAD4TBDL

Product Line:
IEC contactors and starters

Environment:
Products sold and used in the United States

Cause:
Identifying the difference between two similar part numbers

Resolution:
The LAD4TB is for 24V AC coils for the Tesys Series LC1D09 through LC1D38 contactors when supplied with G7 voltage code. The LAD4TBDL is 24 vdc bi-directional diode offered as a replacement if for some reason the diode supplied with the Tesys LC1D09 through LC1D38 contactors when ordered with BD or BL voltage code breaks or is no longer working.


 

Where do I find the Coil voltage on the Tesys D 3 Pole AC Contactor?

On the Tesys D 3 Pole AC Contactor you will find the coil voltage marked at the top, behind the Power terminals of the Contactor, for example U7, 240V 50/60 Hz

For the DC Version, the coil voltage is marked on the front of the Contactor. Hence it has got complete part number for the Contactor on the front, for example: LC1D25BD for 24V DC Coil.