TeSys D, Contactor, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 48VDC coil, screw clamp terminals

TeSys D, Contactor, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 48VDC coil, screw clamp terminals

Item Number: LC1D18ED

Datasheet

Product Dimensions

Width icon

Width45 mm

Height icon

Height77 mm

Depth icon

Depth95 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys Deca

Product or component type

contactor

Warranty

18 months

Physical

[ue] rated operational voltage

  • power circuit: <= 690 V AC 25...400 Hz
  • power circuit: <= 300 V DC

[ie] rated operational current

  • 18 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
  • 32 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • 18 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

Mechanical durability

30 Mcycles

Electrical durability

  • 1.65 Mcycles 18 A AC-3 at Ue <= 440 V
  • 1 Mcycles 32 A AC-1 at Ue <= 440 V
  • 1.65 Mcycles 18 A AC-3e at Ue <= 440 V

Connections - terminals

  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
  • control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
  • control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
  • power circuit: screw clamp terminals 1 1.5-6 mm² - cable stiffness: flexible without cable end
  • power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: flexible without cable end
  • power circuit: screw clamp terminals 1 1-6 mm² - cable stiffness: flexible with cable end
  • power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible with cable end
  • power circuit: screw clamp terminals 1 1.5-6 mm² - cable stiffness: solid without cable end
  • power circuit: screw clamp terminals 2 1.5-6 mm² - cable stiffness: solid without cable end

Insulation resistance

> 10 MOhm for signalling circuit

Mounting support

  • plate
  • rail

Standards

  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 60947-4-1
  • IEC 60335-1:Clause 30.2
  • IEC 60335-2-40:Annex JJ
  • UL 60335-2-40:Annex JJ
  • CSA C22.2 No 60947-4-1

Product certifications

  • UL
  • CCC
  • CSA
  • Marine
  • UKCA
  • EAC
  • CB Scheme

Ip degree of protection

IP20 front face conforming to IEC 60529

Climatic withstand

  • conforming to IACS E10 exposure to damp heat
  • conforming to IEC 60947-1 Annex Q category D exposure to damp heat

Height

77 mm

Width

45 mm

Depth

95 mm

Net weight

0.49 kg

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP110230EN

Circularity profile

ENVEOLI1102030EN

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Life cycle assessment data

Yes

Substance regulation data deliverable

Yes

Package 1 bare product quantity

1

Package 2 bare product quantity

16

Package 3 bare product quantity

256

Packaging made with recycled cardboard

Yes

Packaging without single use plastic

Yes

Device short name

LC1D

Contactor application

  • motor control
  • resistive load

Utilisation category

  • AC-3
  • AC-1
  • AC-4
  • AC-3e

Poles description

3P

[uc] control circuit voltage

48 V DC

Motor power kw

  • 4 kW at 220...230 V AC 50/60 Hz (AC-3)
  • 7.5 kW at 380...400 V AC 50/60 Hz (AC-3)
  • 9 kW at 415...440 V AC 50/60 Hz (AC-3)
  • 10 kW at 500 V AC 50/60 Hz (AC-3)
  • 10 kW at 660...690 V AC 50/60 Hz (AC-3)
  • 4 kW at 400 V AC 50/60 Hz (AC-4)
  • 4 kW at 220...230 V AC 50/60 Hz (AC-3e)
  • 7.5 kW at 380...400 V AC 50/60 Hz (AC-3e)
  • 9 kW at 415...440 V AC 50/60 Hz (AC-3e)
  • 10 kW at 500 V AC 50/60 Hz (AC-3e)
  • 10 kW at 660...690 V AC 50/60 Hz (AC-3e)

Motor power hp

  • 1 hp at 115 V AC 50/60 Hz for 1 phase motors
  • 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
  • 5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
  • 5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
  • 10 hp at 460/480 V AC 50/60 Hz for 3 phases motors
  • 15 hp at 575/600 V AC 50/60 Hz for 3 phases motors

Compatibility code

LC1D

Pole contact composition

3 NO

Protective cover

with

[ith] conventional free air thermal current

  • 10 A (at 60 °C) for signalling circuit
  • 32 A (at 60 °C) for power circuit

Irms rated making capacity

  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
  • 300 A at 440 V for power circuit conforming to IEC 60947

Rated breaking capacity

300 A at 440 V for power circuit conforming to IEC 60947

[icw] rated short-time withstand current

  • 145 A 40 °C - 10 s for power circuit
  • 240 A 40 °C - 1 s for power circuit
  • 40 A 40 °C - 10 min for power circuit
  • 84 A 40 °C - 1 min for power circuit
  • 100 A - 1 s for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 140 A - 100 ms for signalling circuit

Associated fuse rating

  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • 50 A gG at <= 690 V coordination type 1 for power circuit
  • 35 A gG at <= 690 V coordination type 2 for power circuit

Average impedance

2.5 mOhm - Ith 32 A 50 Hz for power circuit

Power dissipation per pole

  • 2.5 W AC-1
  • 0.8 W AC-3
  • 0.8 W AC-3e

[ui] rated insulation voltage

  • power circuit: 690 V conforming to IEC 60947-4-1
  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • signalling circuit: 690 V conforming to IEC 60947-1
  • signalling circuit: 600 V CSA certified
  • signalling circuit: 600 V UL certified

Overvoltage category

III

Pollution degree

3

[uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

Safety reliability level

  • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Control circuit type

DC standard

Coil technology

with integral suppression device

Control circuit voltage limits

  • 0.1...0.25 Uc (-40-70 °C):drop-out DC
  • 0.7...1.25 Uc (-40-60 °C):operational DC
  • 1...1.25 Uc (60-70 °C):operational DC

Inrush power in w

5.4...5.4 W (at 20 °C)

Hold-in power consumption in w

5.4...5.4 W at 20 °C

Operating time

  • 63 ±15 % ms closing
  • 20 ±20 % ms opening

Time constant

28 ms

Maximum operating rate

3600 cyc/h at 60 °C

Tightening torque

  • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
  • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
  • power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Auxiliary contact composition

1 NO + 1 NC

Auxiliary contacts type

  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency

25...400 Hz

Minimum switching voltage

17 V for signalling circuit

Minimum switching current

5 mA for signalling circuit

Non-overlap time

  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact

Contact compatibility

M4

Protective treatment

TH conforming to IEC 60068-2-30

Permissible ambient air temperature around the device

  • -40...60 °C
  • 60...70 °C with derating

Operating altitude

0...3000 m

Fire resistance

850 °C conforming to IEC 60695-2-1

Flame retardance

V1 conforming to UL 94

Mechanical robustness

  • vibrations contactor open (2 Gn, 5...300 Hz)
  • vibrations contactor closed (4 Gn, 5...300 Hz)
  • shocks contactor open (10 Gn for 11 ms)
  • shocks contactor closed (15 Gn for 11 ms)

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

5.000 cm

Package 1 width

9.200 cm

Package 1 length

11.200 cm

Package 1 weight

519.000 g

Unit type of package 2

S02

Number of units in package 2

16

Package 2 height

15 cm

Package 2 width

30 cm

Package 2 length

40 cm

Package 2 weight

8.33 kg

Unit type of package 3

P06

Number of units in package 3

256

Package 3 height

45.000 cm

Package 3 width

60.000 cm

Package 3 length

80.000 cm

Package 3 weight

151.14 kg

Green premium status for reporting

Green Premium product

Sustainable packaging

Yes

Pvc free

Yes

Pvc free

Yes

Take-back

No

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Carbon footprint (kg.eq.co2 per cr, total life cycle)

39.46984074

Global warming ; total life cycle​

39 kg CO2 eq.
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Data Bulletin

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Technical illustration

  • Certificates (MSDS)

  • Declaration of Conformity

  • eTechPub