PowerLogic, Current transformer tropicalised, DIN mount 200 5 cables d. 27 - bars 10x32 15x25

Home ProductsIndustrialPowerLogicCurrent transformer tropicalised

PowerLogic, Current transformer tropicalised, DIN mount 200 5 cables d. 27 - bars 10x32 15x25

Item Number: METSECT5MA020

This current transformer, tropicalised for busbar and cable, has a line rated current of 200 A and a secondary current rating of 5 A. This current transformer allow a maximum cable outer diameter of 27 mm. Compatible with a double output for bar: 32.5 mm x 10.5 mm or 25.5 mm x 15.5 mm. Burden and accuracy class as follows: class 0.5 maximum power: 4 VA, class 1 maximum power: 7 VA.

Datasheet

Product Dimensions

Width icon

Widthoutside: 56 mm

Height icon

Heightoutside: 80 mm

Depth icon

Depthframe : 43 mm|total : 63 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

PowerLogic

Range of product

PowerLogic CT

Product or component type

current transformer

Sustainable offer status

Green Premium product

Physical

[in] rated current

200 A

[ue] rated operational voltage

< 720 V AC 50/60 Hz

Mounting mode

clip-on|by screws|insulated locking screw

Mounting support

DIN rail|busbar|mounting plate

Width

outside: 56 mm

Height

outside: 80 mm

Depth

frame : 43 mm|total : 63 mm

Net weight

0.318 kg

Electrical insulation class

class B

Cable outer diameter

27 mm

Standards

IEC 61869-2|VDE 0414

Product certifications

EAC|CE

Ip degree of protection

IP20

Relative humidity

0...95 %

Ambient air temperature for operation

-25...60 °C

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

China rohs regulation

X

Rohs exemption information

Yes

Environmental disclosure

ENVPEP111007EN

Circularity profile

ENVEOLI111006

Others

Package 1 bare product quantity

1

Product name

CT

Secondary current

5 A

Accuracy class

class 0.5 at 4 VA|class 1 at 7 VA

Current transformer type

tropicalised for busbar and cable

Current transformer ratio

200/5

[ith] conventional free air thermal current

12 kA

Dynamic withstand current

2.5 Ith

Maximum safety factor

5

[ui] rated insulation voltage

3 kV

Diameter

27 mm

[uimp] rated impulse withstand voltage

3 kV

Opening of bars

32.5 x 10.5|25.5 x 15.5

Sealing

without

Compatibility code

MA

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

7.000 cm

Package 1 width

7.000 cm

Package 1 length

9.000 cm

Package 1 weight

320 g

Unit type of package 2

S03

Number of units in package 2

35

Package 2 height

30.000 cm

Package 2 width

30.000 cm

Package 2 length

40.000 cm

Package 2 weight

11.641 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications