PM2000 series, Power & Energy meter, up to the 15th harmonic, LCD display, RS485, class 1

PM2000 series, Power & Energy meter, up to the 15th harmonic, LCD display, RS485, class 1

Item Number: METSEPM2220

Datasheet

Product Dimensions

Width icon

Width96 mm

Height icon

Height96 mm

Depth icon

Depthtotal : 76.09 mm|embedded : 61.64 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

EasyLogic

Product or component type

power meter

Device application

power monitoring|sub billing

Physical

[in] rated current

1 A|5 A

Control type

4 x button

Local signalling

red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)|green LED: module operation and integrated communication

Communication port protocol

Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V

Function available

real time clock

Product certifications

CE conforming to IEC 61010-1|cULus conforming to UL 61010-1|cULus conforming to CSA C22.2 No 61010-1|RCM|EAC|C-Tick

Mounting mode

clip-on

Mounting position

vertical

Mounting support

framework

Provided equipment

1 x installation guide

Electrical insulation class

double insulation|class II

Connections - terminals

current transformer: screw connection (bottom) 6 |voltage inputs: screw connection (top) 4

Width

96 mm

Depth

total : 76.09 mm|embedded : 61.64 mm

Height

96 mm

Net weight

300 g

Ip degree of protection

IP54 front: conforming to IEC 60529|IP30 body: conforming to IEC 60529

Relative humidity

5...95 % at 50 °C

Ambient air temperature for operation

-10...60 °C

Ambient air temperature for storage

-25...70 °C

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP1510004_V2

Circularity profile

ENVEOLI1510004_V2

Material

Material

polycarbonate

Others

Package 1 bare product quantity

1

Product name

EasyLogic PM2200

Device short name

PM2220

Power quality analysis

total harmonic distortion| up to the 15th harmonic

Type of measurement

apparent power min/max, total|active and reactive power min/max, total|current min/max, avg|voltage min/max, avg|frequency min/max, avg|total current harmonic distortion THD (I) per phase|total voltage harmonic distortion THD (U) per phase|power factor min/max, avg|apparent energy total|active and reactive energy total

Metering type

active, reactive, apparent energy (signed, four quadrant)|current I, I1, I2, I3|peak demand currents|peak demand power PM, QM, SM|unbalance current|active power P, P1, P2, P3|reactive power Q, Q1, Q2, Q3|demand power P, Q, S|voltage U, U21, U32, U13, V, V1, V2, V3|apparent power S, S1, S2, S3|calculated neutral current

Accuracy class

class 1 active energy conforming to IEC 62053-21|class 1 reactive energy conforming to IEC 62053-24|class 5 harmonic distorsion (I THD & U THD)

Measurement accuracy

apparent power +/- 1 %|active energy +/- 1 %|reactive energy +/- 1 %|active power +/- 1 %|voltage +/- 0.5 %|power factor +/- 0.01|current +/- 0.5 %|frequency +/- 0.05 %

Measurement current

5...6000 mA

Measurement voltage

35...480 V AC 50/60 Hz between phases|20...277 V AC 50/60 Hz between phase and neutral|480...999000 V AC 50/60 Hz with external VT

Frequency measurement range

45...65 Hz

[us] rated supply voltage

44...277 V AC 45...65 Hz +/- 10 %|44...277 V DC +/- 10 %

Network frequency

50 Hz|60 Hz

Maximum power consumption in va

6 VA at 277 V AC

Maximum power consumption in w

3.3 W (power lines (AC))|2 W at 277 V (power lines (DC))

Analogue input type

current (impedance <= 0.3 mOhm)|voltage (impedance > 5 MOhm)

Tamperproof of settings

protected by access code

Display type

backlit LCD

Display colour

monochrome

Display resolution

128 x 128 pixels

Refresh time

configurable from 1 to 60 min

Information displayed

demand current (past value)|demand current (present value)|demand power (past value)|demand power (present value)|voltage|current|frequency|energy consumption|harmonic distortion|power factor|active power|apparent power|reactive power|unbalanced in %|harmonic amplitude

Number of inputs

0

Number of outputs

0

Communication port support

screw terminal block: RS485

Data recording

time stamping|min/max for 8 parameters

Sampling rate

64 samples/cycle

Cybersecurity

enable/disable communication ports

Communication service

remote monitoring

User language

Spanish|French|English|Russian|Portuguese|German|Chinese

Measurement category

category III 480-480 V|category II 480-600 V

Flame retardance

V-0 conforming to UL 94

Compatibility code

PM2220

Service life

7 year(s)

Pollution degree

2

Operating altitude

<= 2000 m

Electromagnetic compatibility

electrostatic discharge conforming to IEC 61000-4-2|radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3|electrical fast transient/burst immunity test conforming to IEC 61000-4-4|surge immunity test conforming to IEC 61000-4-5|conducted RF disturbances conforming to IEC 61000-4-6|magnetic field at power frequency conforming to IEC 61000-4-8|voltage dips and interruptions immunity test conforming to IEC 61000-4-11|emission tests conforming to FCC part 15 class A

Overvoltage category

III

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

8.9 cm

Package 1 width

12.2 cm

Package 1 length

11.7 cm

Package 1 weight

270 g

Scip number

6599793e-9401-4187-a617-35919522fe23

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Carbon footprint (kg.eq.co2 per cr, total life cycle)

31.6958044738
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Other technical guide

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Operating Manuals

  • Declaration of Conformity

  • Firmware

  • Software - Hotfix