Modicon TM3, Safety module, 3 Function, Cat 4 PL e/SIL CL3 (spring) 24 VDC

Modicon TM3, Safety module, 3 Function, Cat 4 PL e/SIL CL3 (spring) 24 VDC

Item Number: TM3SAK6RG

Datasheet

Product Dimensions

Width icon

Width43.7 mm

Height icon

Height94 mm

Depth icon

Depth73 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Modicon TM3 Safety

Product or component type

safety module

Product compatibility

safety light curtains conforming to EN/IEC 61496-1 (type 4)|sensing mat/edges conforming to EN 1760-1

Sustainable offer status

Green Premium product

Physical

Function of module

emergency stop monitoring 1-channel wiring|emergency stop monitoring 2-channel wiring|monitoring of a movable guard with 2 switches and automatic start|monitoring of a movable guard|multiple emergency stop monitoring 2-channel wiring|proximity sensor monitoring PNP/PNP|proximity sensor monitoring PNP/NPN|sensing mat and edges monitoring|monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP|monitoring of electro-sensitive protection equipment (ESPE) PNP/NPN

Connections - terminals

captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34|captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34|captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34|captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34|captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34|captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals|captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals|captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals|captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals

Power consumption in w

0.2 W at 5 V DC|3.6 W at 24 V DC

Local signalling

8 LEDs (green/red) for user

Standards

ISO 13849-1:2008|ISO 13849-2:2012|IEC 62061:2005|IEC 61508:2010|IEC 60947-5-1:2010|IEC 61131-2:2007|IEC 60204-1:2005|IEC 60204-1:2009/A1|IEC 61010-1:2010|EN 50581:2012

Product certifications

CSA 61010-2-201 (pending)|TÜV|CSA Haz Loc Class 1 Division 2 (pending)|EAC|RCM|UL 61010-2-201|ANSI Haz Loc Class 1 Division 2 (pending)

Marking

CSA|RCM|UL|EFUP 10|CE|TÜV|EAC

Mounting support

top hat type TH35-7.5 rail conforming to IEC 60715|top hat type TH35-15 rail conforming to IEC 60715| wall mount using attached fasteners

Height

94 mm

Depth

73 mm

Width

43.7 mm

Net weight

0.19 kg

Standards

EN 1088/ISO 14119|IEC 60947-5-1|IEC 60947-1|IEC 60204-1|ISO 13850

Ambient air temperature for operation

-10...55 °C horizontal installation

Ambient air temperature for storage

-25...70 °C

Relative humidity

10...95 %, without condensation (in operation)|10...95 %, without condensation (in storage)

Ip degree of protection

IP20 (terminals) conforming to IEC 60529

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP1403010EN

Circularity profile

ENVEOLI1403010EN

California proposition 65

"WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"

Others

Package 1 bare product quantity

1

Device short name

TM3SAK

Safety module application

for emergency stop, switch, sensing mat/edges or safety light curtain monitoring

Safety level

can reach PL e/category 4 conforming to ISO 13849-1: 2008|can reach PL e/category 4 conforming to ISO 13849-2: 2012|can reach SILCL 3 conforming to IEC 62061: 2005|can reach SIL 3 conforming to IEC 61508: 2010

Safety reliability data

DC = 95 % conforming to ISO 13849-1|PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A|PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A|MTTFd = 500 years conforming to ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A|MTTFd = 85 years conforming to ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A|SFF = 95 % conforming to IEC 61508-1|HFT = 1 conforming to IEC 61508-1|type = A conforming to IEC 61508-1

Synchronisation time between inputs

unlimited|2 or 4 s depending of wiring configurable by software

Output type

relay instantaneous opening, 3 NO circuit(s), potential free

Number of safety circuits

3 NO for relay instantaneous opening

Maximum switching voltage

230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening)|24 V utilisation category DC-13 (relay instantaneous opening)

[us] rated supply voltage

24 V - 15...20 % DC

Input protection type

internal, electronic

[uc] control circuit voltage

24 V DC

Maximum cable distance between devices

30 m

Breaking capacity

360 VA holding AC-15 B300 relay output|3600 VA inrush AC-15 B300 relay output

Breaking capacity

4 A 24 V 50 ms DC-13 relay output

Output thermal current

6 A per relay for relay output

[ith] conventional free air thermal current

18 A

Associated fuse rating

4 A gG or gL for relay output conforming to IEC 60947-5-1|6 A fast blow for relay output conforming to IEC 60947-5-1

Minimum output current

10 mA for relay output

Output voltage

10 V relay output

Maximum response time on input open

40 ms

[ui] rated insulation voltage

300 V (pollution degree 2) conforming to IEC 60647-5-1

[uimp] rated impulse withstand voltage

4 kV overvoltage category III conforming to IEC 60647-5-1

Current consumption

100 mA at 24 V DC external supply

Electrical connection

spring terminal

Electromagnetic compatibility

electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2|electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2|susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to IEC 61000-4-3|susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3|susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to IEC 61000-4-3|magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8|electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to IEC 61000-4-4|electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to IEC 61000-4-4|1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5|conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6|radiated emission - test level: 40 dBµV/m class A (24 V) conforming to IEC 55011|radiated emission - test level: 47 dBµV/m class A (24 V) conforming to IEC 55011

Resistance to electrostatic discharge

8 kV in air conforming to IEC 61000-4-2|6 kV on contact conforming to IEC 61000-4-2

Resistance to electromagnetic fields

10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3|3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3|1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3

Resistance to magnetic fields

30 A/m 50/60 Hz conforming to IEC 61000-4-8

Resistance to fast transients

3 kV for power lines (DC) (DC) conforming to IEC 61000-4-4|2 kV for I/O lines conforming to IEC 61000-4-4

Surge withstand

1 kV power lines (DC) differential mode conforming to IEC 61000-4-5 DC|1 kV power lines (DC) common mode conforming to IEC 61000-4-5 DC

Resistance to conducted disturbances

10 V 0.15...80 MHz conforming to IEC 61000-4-6

Electromagnetic emission

radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30-230 Hz conforming to IEC 61131-3|radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230-1000 Hz conforming to IEC 61131-3

Pollution degree

2

Operating altitude

0...2000 m

Storage altitude

0...3000 m

Vibration resistance

+/- 3.5 mm (f= 5-150 Hz) conforming to IEC 60068-2-6

Shock resistance

15 gn for 11 ms conforming to IEC 60068-2-27

Mechanical robustness

bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

7.500 cm

Package 1 width

10.600 cm

Package 1 length

12.500 cm

Package 1 weight

236.000 g

Unit type of package 2

S03

Number of units in package 2

18

Package 2 height

30.000 cm

Package 2 width

30.000 cm

Package 2 length

40.000 cm

Package 2 weight

5.344 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Pvc free

Yes
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Environmental Disclosure

  • End of Life Manual

  • Operating Manuals

  • Application Notes

  • Certificates (MSDS)

  • Declaration of Conformity

  • eTechPub