Specifications

Design

Range of product

Modicon M221

Product or component type

logic controller

Physical

Inrush current

40 A

Electrical durability

100000 cycles AC-12, 120 V, 240 VA, resistive|100000 cycles AC-12, 240 V, 480 VA, resistive|300000 cycles AC-12, 120 V, 80 VA, resistive|300000 cycles AC-12, 240 V, 160 VA, resistive|100000 cycles AC-15, cos phi = 0.35 , 120 V, 60 VA, inductive|100000 cycles AC-15, cos phi = 0.35 , 240 V, 120 VA, inductive|300000 cycles AC-15, cos phi = 0.35 , 120 V, 18 VA, inductive|300000 cycles AC-15, cos phi = 0.35 , 240 V, 36 VA, inductive|100000 cycles AC-14, cos phi = 0.7 , 120 V, 120 VA, inductive|100000 cycles AC-14, cos phi = 0.7 , 240 V, 240 VA, inductive|300000 cycles AC-14, cos phi = 0.7 , 120 V, 36 VA, inductive|300000 cycles AC-14, cos phi = 0.7 , 240 V, 72 VA, inductive|100000 cycles DC-12, 24 V, 48 W, resistive|300000 cycles DC-12, 24 V, 16 W, resistive|100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)|300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)

Mechanical durability

20000000 cycles for relay output

Protection type

without protection at 5 A

Backup time

1 year at 25 °C (by interruption of power supply)

Control signal type

single phase|frequency meter|dual phase (quadrature)|dual phase (pulse/direction)

Integrated connection type

USB port with mini B USB 2.0 connector|non isolated serial link serial 1 with RJ45 connector and RS485 interface |non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface

Supply

(serial)serial link supply: 5 V, <200 mA

Communication port protocol

USB port: USB - SoMachine-Network|non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network

Local signalling

1 LED (green) for PWR|1 LED (green) for RUN|1 LED (red) for module error (ERR)|1 LED (green) for SD card access (SD)|1 LED (red) for BAT|1 LED (green) for SL1|1 LED (green) for SL2|1 LED per channel (green) for I/O state

Marking

CE

Mounting support

top hat type TH35-15 rail conforming to IEC 60715|top hat type TH35-7.5 rail conforming to IEC 60715| plate or panel with fixing kit

Height

90 mm

Depth

70 mm

Width

95 mm

Net weight

0.346 kg

Standards

IEC 61131-2|UL 508|CAN/CSA C22.2 No. 213|IACS E10|ANSI/ISA 12-12-01

Product certifications

RCM|ABS|LR|DNV-GL|EAC|cULus|CE|UKCA|cULus HazLoc

Environmental characteristic

ordinary and hazardous location

Ambient air temperature for operation

-10...55 °C (horizontal installation)|-10...35 °C (vertical installation)

Ambient air temperature for storage

-25...70 °C

Relative humidity

10...95 %, without condensation (in operation)|10...95 %, without condensation (in storage)

Ip degree of protection

IP20 with protective cover in place

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP1403012EN

Circularity profile

ENVEOLI1403012EN

California proposition 65

WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Package 1 bare product quantity

1

Package 2 bare product quantity

20

Package 3 bare product quantity

240

[us] rated supply voltage

100...240 V AC

Discrete input number

9 , discrete input conforming to IEC 61131-2 Type 1

Analogue input number

2 at 0...10 V

Discrete output type

relay normally open

Discrete output number

7 relay

Discrete output voltage

5...125 V DC|5...250 V AC

Discrete output current

2 A

Discrete i/o number

16

Maximum number of i/o expansion module

4 (local I/O-Architecture)|11 (remote I/O-Architecture)

Supply voltage limits

85...264 V

Network frequency

50/60 Hz

Maximum power consumption in va

46 VA at 100...240 V with max number of I/O expansion module|31 VA at 100...240 V without I/O expansion module

Power supply output current

0.325...0.325 A 5 V for expansion bus|0.12...0.12 A 24 V for expansion bus

Discrete input logic

sink or source (positive/negative)

Discrete input voltage

24 V

Discrete input voltage type

DC

Analogue input resolution

10 bits

Lsb value

10 mV

Conversion time

1 ms per channel + 1 controller cycle time for analogue input analog input

Permitted overload on inputs

+/- 30 V DC for 5 min (maximum) for analog input|+/- 13 V DC (permanent) for analog input

Voltage state 1 guaranteed

>= 15 V for input

Voltage state 0 guaranteed

<= 5 V for input

Discrete input current

7 mA for discrete input|5 mA for fast input

Input impedance

3.4 kOhm for discrete input|100 kOhm for analog input|4.9 kOhm for fast input

Response time

35 µs turn-off, I2...I5 terminal(s) for input|10 ms turn-on for output|10 ms turn-off for output|5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input|35 µs turn-on, other terminals terminal(s) for input|5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input|100 µs turn-off, other terminals terminal(s) for input

Configurable filtering time

0 ms for input|3 ms for input|12 ms for input

Output voltage limits

125 V DC|277 V AC

Maximum current per output common

6 A at COM 1|7 A at COM 0

Absolute accuracy error

+/- 1 % of full scale for analog input

Switching frequency

20 switching operations/minute with maximum load

Minimum load

1 mA at 5 V DC for relay output

Reset time

1 s

Memory capacity

256 kB for user application and data RAM with 10000 instructions|256 kB for internal variables RAM

Data backed up

256 kB built-in flash memory for backup of application and data

Data storage equipment

2 GB SD card (optional)

Battery type

BR2032 or CR2032X lithium non-rechargeable

Execution time for 1 kinstruction

0.3 ms for event and periodic task

Execution time per instruction

0.2 µs Boolean

Exct time for event task

60 µs response time

Maximum size of object areas

512 %KW constant words|512 %M memory bits|255 %C counters|8000 %MW memory words|255 %TM timers

Realtime clock

with

Clock drift

<= 30 s/month at 25-25 °C

Regulation loop

adjustable PID regulator up to 14 simultaneous loops

Counting input number

4 fast input (HSC mode) at 100 kHz 32 bits

Transmission rate

1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15-15 m for RS485|1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3-3 m for RS232|480 Mbit/s for USB

Electrical connection

removable screw terminal block for inputs| removable screw terminal block for outputs| terminal block, 3 terminal(s) for connecting the 24 V DC power supply| connector, 4 terminal(s) for analogue inputs|mini B USB 2.0 connector for a programming terminal

Maximum cable distance between devices

shielded cable: <10 m for fast input|unshielded cable: <30 m for output|unshielded cable: <30 m for digital input|unshielded cable: <1 m for analog input

Insulation

between input and internal logic at 500 V AC|non-insulated between analogue input and internal logic|non-insulated between analogue inputs|between supply and ground at 1500 V AC|between sensor power supply and ground at 500 V AC|between input and ground at 500 V AC|between output and ground at 1500 V AC|between supply and internal logic at 2300 V AC|between sensor power supply and internal logic at 500 V AC|between output and internal logic at 2300 V AC|between Ethernet terminal and internal logic at 500 V AC|between supply and sensor power supply at 2300 V AC

Sensor power supply

24 V DC at 250 mA supplied by the controller

Resistance to electrostatic discharge

8 kV in air conforming to IEC 61000-4-2|4 kV on contact conforming to IEC 61000-4-2

Resistance to electromagnetic fields

10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3|3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3|1 V/m 2...2.7 GHz conforming to IEC 61000-4-3

Resistance to magnetic fields

30 A/m 50/60 Hz conforming to IEC 61000-4-8

Resistance to fast transients

2 kV (power lines) conforming to IEC 61000-4-4|2 kV (relay output) conforming to IEC 61000-4-4|1 kV (I/O) conforming to IEC 61000-4-4|1 kV (Ethernet line) conforming to IEC 61000-4-4|1 kV (serial link) conforming to IEC 61000-4-4

Surge withstand

2 kV power lines (AC) common mode conforming to IEC 61000-4-5|2 kV relay output common mode conforming to IEC 61000-4-5|1 kV I/O common mode conforming to IEC 61000-4-5|1 kV shielded cable common mode conforming to IEC 61000-4-5|0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5|1 kV power lines (AC) differential mode conforming to IEC 61000-4-5|1 kV relay output differential mode conforming to IEC 61000-4-5|0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5

Resistance to conducted disturbances

10 V 0.15...80 MHz conforming to IEC 61000-4-6|3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL)|10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)

Electromagnetic emission

conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15-0.5 MHz conforming to IEC 55011|conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5-300 MHz conforming to IEC 55011|conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10-150 kHz conforming to IEC 55011|conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5-30 MHz conforming to IEC 55011|radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30-230 MHz conforming to IEC 55011|conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150-1500 kHz conforming to IEC 55011|radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200-1000 MHz conforming to IEC 55011

Immunity to microbreaks

10 ms

Pollution degree

<= 2

Operating altitude

0...2000 m

Storage altitude

0...3000 m

Vibration resistance

3.5 mm at 5-8.4 Hz on symmetrical rail|3.5 mm at 5-8.4 Hz on panel mounting|1 gn at 8.4-150 Hz on symmetrical rail|1 gn at 8.4-150 Hz on panel mounting

Shock resistance

98 m/s² for 11 ms

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

10.6 cm

Package 1 width

14.0 cm

Package 1 length

13.9 cm

Package 1 weight

300.0 g

Unit type of package 2

S04

Number of units in package 2

20

Package 2 height

30 cm

Package 2 width

40 cm

Package 2 length

60 cm

Package 2 weight

6.983 kg

Unit type of package 3

P12

Number of units in package 3

240

Package 3 height

105.0 cm

Package 3 width

120.0 cm

Package 3 length

80.0 cm

Package 3 weight

162 kg

Scip number

db4bbd5b-c14f-4e05-90f0-9ef8d1e54486

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Pvc free

Yes

Pvc free

Yes

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Carbon footprint (kg.eq.co2 per cr, total life cycle)

78.16698595814708
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Environmental Disclosure

  • End of Life Manual

  • Operating Manuals

  • System User Guide

  • Certificates (MSDS)

  • eTechPub

  • Declaration of Conformity