Harmony XB5R, Programmable receiver, 2 relays, 24..240 V AC/DC, 2 pusbuttons, 6 LEDs

Home ProductsIndustrialHarmonyProgrammable receiver

Harmony XB5R, Programmable receiver, 2 relays, 24..240 V AC/DC, 2 pusbuttons, 6 LEDs

Item Number: ZBRRA

Datasheet

Product Dimensions

Width icon

Width36 mm

Height icon

Height108 mm

Depth icon

Depth75 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Harmony

Product or component type

programmable receiver

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Function of module

bi-stable|monostable|stop/start

Transmission frequency

2405 MHz

Communication port protocol

Zigbee green power at 2.4 GHz conforming to IEEE 802.15.4

Mounting support

35 mm symmetrical DIN rail conforming to IEC 60715|mounting plate

Number of channels

1

Width

36 mm

Height

108 mm

Depth

75 mm

Net weight

0.13 kg

Standards

CSA C22.2 No 14|UL 508|IEC 60947-5-1|IEC 60947-1

Product certifications

C-Tick|CCC|CSA|UL|GOST

Marking

CE

Ambient air temperature for storage

-40...70 °C

Relative humidity

90 % at -20...55 °C, without condensation conforming to ETSI EN 300 440...1

Ip degree of protection

IP20 (casing) conforming to IEC 60529|IP20 (terminals)

Insulation resistance

> 500 MOhm at 500 V DC conforming to NF C 20-030

Electrical durability

100000 cycles

Mechanical durability

1000000 cycles

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP101106EN

Circularity profile

ENVEOLI1103010EN

California proposition 65

"WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"

Others

Package 1 bare product quantity

1

Device short name

ZBRRA

Product specific application

interface to actuators

Reset time

2 ms time delay

Level or class

5M00G7W

Antenna type

omnidirectional

Nominal output current

0.3 A at 48 V DC conforming to IEC 60947-5-1|3 A at 24 V DC conforming to UL 508|1.5 A at 240 V AC conforming to IEC 60947-5-1|3 A at 120 V AC conforming to IEC 60947-5-1|3 A at 240 V AC conforming to UL 508|3 A at 24 V DC conforming to CSA C22.2 No 14|3 A at 240 V AC conforming to CSA C22.2 No 14

Output type

2 relays

Output contacts

2 C/O

Input output isolation

galvanic isolation

Time delay range

0.5 s (tolerance: - 15...15 %)

Switching capacity in va

1250 VA

Maximum switching current

5 mA AC/DC

Maximum switching voltage

250 V AC/DC

[us] rated supply voltage

24...240 V AC/DC 50/60 Hz - 10...10 %

Maximum sensing distance

100 m in free field|25 m transmitter in a plastic box type XAL D and receiver in a metal enclosure|40 m transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna

Response time

< 30 ms after transmitter clicks

Utilisation category

AC-15 : B300 conforming to IEC 60947-5-1|DC-12 conforming to IEC 60947-5-1

Maximum power consumption in w

4 W AC/DC

Breaking capacity

15 W

Breaking capacity

750 VA

Control circuit frequency

50...60 Hz +/- 10 %

Short-circuit protection

0.4 A fuse type fast blow

Operating position

any position without derating

Electrical connection

1 conductor cable 0.14-2.5 mm² - AWG 26...AWG 14 - solid - without cable end conforming to IEC 60947-1|2 conductors cable 0.14-1.5 mm² - AWG 26...AWG 16 - solid - without cable end conforming to IEC 60947-1|1 conductor cable 0.14-4 mm² - AWG 26...AWG 12 - flexible - with cable end conforming to IEC 60947-1|2 conductors cable 0.14-1.5 mm² - AWG 26...AWG 16 - flexible - with cable end conforming to IEC 60947-1

Tightening torque

0.5...1 N.m conforming to IEC 60947...1

Housing material

self-extinguishing plastic

Status led

1 LED green for power ON|2 LEDs green for relay ON|2 LEDs green for function mode|1 LED green and yellow for reception signal

Rated short-duration power frequency withstand voltage

1.5 kV 50 Hz conforming to IEC 60947-5-1

[uimp] rated impulse withstand voltage

4 kV

Surge withstand

1 kV differential mode conforming to IEC 61000-4-5|2 kV common mode conforming to IEC 61000-4-5

Max power consumption in w

1 mW

Modulation technique

O-QPSK

Bandwidth

5 MHz

Antenna gain

0 dBi

[us] rated supply voltage

24...240 V

Radio agreement

RSS|SRRC|ANATEL|ARIB T66|FCC|ICASA

Vibration resistance

+/- 7.5 mm (f= 5-14 Hz) conforming to IEC 60068-2-6|2 gn (f= 8-150 Hz) conforming to IEC 60068-2-6

Shock resistance

10 gn (duration = 16 ms) for 6000 shocks conforming to IEC 60068-2-27

Pollution degree

2 conforming to IEC 60664-1

Overvoltage category

II conforming to IEC 60664-1

[ui] rated insulation voltage

250 V conforming to IEC 60664-1

Electromagnetic compatibility

immunity for industrial environments conforming to IEC 61000-6-2|conducted and radiated emissions class B conforming to CISPR 22|electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2|electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2|susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz) conforming to IEC 61000-4-3|susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m) conforming to IEC 61000-4-3|electrical fast transient/burst immunity test - test level: 2 kV (relay wires) conforming to IEC 61000-4-4|electrical fast transient/burst immunity test - test level: 2 kV (power supply wires) conforming to IEC 61000-4-4|1.2/50 µs shock waves immunity test - test level: 1 kV (differential mode) conforming to IEC 61000-4-5|1.2/50 µs shock waves immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5|conducted RF disturbances - test level: 10 V conforming to IEC 61000-4-6|immunity to microbreaks and voltage drops - test level: 10 ms conforming to IEC 61000-4-11|radiated emission conforming to ETSI EN 300 440-1|conducted emission conforming to EN 300-489-1|conducted emission conforming to ETSI EN 300 489-3|radiated emission conforming to ETSI EN 300 440-2

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

4.6 cm

Package 1 width

8 cm

Package 1 length

9.6 cm

Package 1 weight

138 g

Unit type of package 2

S03

Number of units in package 2

64

Package 2 height

30 cm

Package 2 width

30 cm

Package 2 length

40 cm

Package 2 weight

9.479 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Installation Instruction

  • Environmental Disclosure

  • End of Life Manual

  • Operating Manuals

  • Technical illustration

  • Application Notes

  • Declaration of Conformity

  • Certificates (MSDS)

  • eTechPub

Frequently Asked Questions

hide show

What is the difference between ZBRRC, ZBRRA, and ZBRRD?

Issue:
Functions and mode of ZBRRC, ZBRRA, and ZBRRD

Product Line:
Push Buttons and Operator Interface

Environment:
XB5R Wireless Push Buttons

Cause:
Product Selection

Resolution:
ZBRRC has 4 programmable PNP outputs rated at 200mA. The ZBRRA and ZBRRD has 2 programmable relay outputs and is rated at 3A.
ZBRRC - momentary (monostable)
ZBRRD - Can be programmed for momentary (monostable), or maintained (bi-stable).
ZBRRA - Can be programmed for momentary (monostable), maintained (bi-stable), Stop/start