Harmony XALD XALK, Control station, plastic, dark grey lid, 1 selector key switch 22mm, 1NO

Harmony XALD XALK, Control station, plastic, dark grey lid, 1 selector key switch 22mm, 1NO

Item Number: XALD144

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Harmony XALD

Product or component type

complete control station

Product destination

for XB5 Ø 22 mm control and signalling units

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Cable entry

2 knock-outs for cable entry, clamping capacity: 14-14 mm|2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12-12 mm

Net weight

0.187 kg

Mechanical durability

1000000 cycles

Connections - terminals

screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1|screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1

[ie] rated operational current

6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1|3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1|1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1|0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1|0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1|0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1

Electrical durability

1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C|1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C|1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C|1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C|1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

Ambient air temperature for storage

-40...70 °C

Ambient air temperature for operation

-40...70 °C

Ip degree of protection

IP66 conforming to IEC 60529|IP67|IP69|IP69K

Ik degree of protection

IK03 conforming to IEC 62262

Standards

IEC 60947-5-1|CSA C22.2 No 14|UL 508|JIS C8201-5-1|IEC 60947-5-5|IEC 60947-5-4|IEC 60947-1|JIS C8201-1

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

China rohs regulation

X

Rohs exemption information

Yes

Environmental disclosure

ENVPEP1806010EN

Circularity profile

ENVEOLI1806010EN

California proposition 65

"WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"

Material

Material

polycarbonate

Contacts material

silver alloy (Ag/Ni)

Others

Package 1 bare product quantity

1

Device short name

XALD

Control station application

Start-Stop function

Colour of base of enclosure

light grey (RAL 7035)

Colour of cover

dark grey (RAL 7016)

Operator profile

1 key selector switch

Operators description

key switch ''O-I'' 1 NO

Control station composition

1 key selector switch 1 NO O-I marking

Marking location

marking on legend holder

Contact operation

slow-break

Resistance to high pressure washer

7000000 Pa at 55 °C, distance : 0.1 m

Operator position information

2 positions

Key number

455

Key withdrawal position

left-hand

Positive opening

without

Operating travel

4.3 mm (total travel)

Torque value

0.14 N.m NO changing electrical state

Tightening torque

0.8...1.2 N.m conforming to IEC 60947...1

Shape of screw head

cross compatible with Philips no 1 screwdriver|cross compatible with pozidriv No 1 screwdriver|slotted compatible with flat Ø 4 mm screwdriver|slotted compatible with flat Ø 5.5 mm screwdriver

Short-circuit protection

10 A cartridge fuse type gG conforming to IEC 60947-5-1

[ith] conventional free air thermal current

10 A conforming to IEC 60947-5-1

[ui] rated insulation voltage

600 V (pollution degree 3) conforming to IEC 60947-1

[uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-1

Electrical reliability

λ < 10exp(-6) at 5 V, 1 mA conforming to IEC 60947-5-4|λ < 10exp(-8) at 17 V, 5 mA conforming to IEC 60947-5-4

Compatibility code

XALD

Protective treatment

TH

Overvoltage category

class II conforming to IEC 60536

Nema degree of protection

NEMA 13|NEMA 4X

Vibration resistance

5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6

Shock resistance

30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27|50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

7.0 cm

Package 1 width

7.0 cm

Package 1 length

10.0 cm

Package 1 weight

187.0 g

Unit type of package 2

S03

Number of units in package 2

40

Package 2 height

30 cm

Package 2 width

30 cm

Package 2 length

40 cm

Package 2 weight

7.94 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Declaration of Conformity

  • Certificates (MSDS)

  • eTechPub