Specifications

Design

Range of product

Altivar 312

Product or component type

variable speed drive

Product destination

asynchronous motors

Warranty

18 months

Physical

Supply

  • internal supply for logic inputs: 19...30 V 100 mA, protection type: overload and short-circuit protection
  • internal supply for reference potentiometer (2.2 to 10 kOhm): 10...10.8 V 10 mA, protection type: overload and short-circuit protection

Communication port protocol

  • CANopen
  • Modbus

Ip degree of protection

  • IP20 on upper part without cover plate
  • IP21 on connection terminals
  • IP31 on upper part
  • IP41 on upper part

Protection type

  • input phase breaks: drive
  • line supply overvoltage and undervoltage safety circuits: drive
  • line supply phase loss safety function, for three phases supply: drive
  • motor phase breaks: drive
  • overcurrent between output phases and earth (on power up only): drive
  • overheating protection: drive
  • short-circuit between motor phases: drive
  • thermal protection: motor

Insulation resistance

>= 500 mOhm 500 V DC for 1 minute

Local signalling

  • 1 LED (red) for drive voltage
  • four 7-segment display units for CANopen bus status

Connector type

1 RJ45 for Modbus/CANopen

Marking

CE

Height

143 mm

Width

107 mm

Depth

152 mm

Net weight

1.8 kg

Standards

  • IEC 61800-3
  • IEC 61800-5-1

Product certifications

  • UL
  • DNV
  • C-Tick
  • CSA
  • NOM
  • GOST

Relative humidity

  • 5...95 % without condensation conforming to IEC 60068...2-3
  • 5...95 % without dripping water conforming to IEC 60068...2-3

Ambient air temperature for storage

-25...70 °C

Ambient air temperature for operation

  • -10...50 °C without derating (with protective cover on top of the drive)
  • -10...60 °C with derating factor (without protective cover on top of the drive)

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

California proposition 65

WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • End of Life Manual

  • Operating Manuals

  • Certificates (MSDS)

  • Declaration of Conformity

  • Software - Data Library

  • Page 2  /  4
  • Page 3  /  4
  • Page 4  /  4

Frequently Asked Questions

hide show

What is the din rail mounting kit part number for the ATV312?

Issue:
Part number for ATV312 Din rail mounting kit

Product Line:
ATV312

Environment:
All

Cause:
Desire to utilize din mounting kit option

Resolution:
The part numbers need to order the mounting kit for this drive are VW3A9804 and VW3A9805.

VW3A9804 covers the following range of drives: ATV312....
018M2, H037M2, H055M2, H075M2, H018M3, H037M3, H055M3, H075M3

VW3A9805 covers the following range of drives: ATV312....
HU11M2, HU15M2, HU11M3, HU15M3, HU22M3, H037N4, H055N4, H075N4, HU11N4, HU15N4, H075S6, HU15S6
Note: The din rail mounting kits are only available for the above drives. 

Note: Other drives not list above do not have a din rail kit.

Can the ATV312 be powered by an external 24V only?

Issue:
Powering the ATV312 by an external 24Vdc only

Product Line:
Altivar 312

Environment:
All

Cause:
Installation/programming
 
Resolution:
No, this drive must have line voltage applied. The voltage must be within -15% to +10% of the rated line voltage.