Altistart 01, Soft starter for asynchronous motor, ATS01, 3 A-110..480V-0.55..1.1 KW

Home ProductsIndustrialAltistartSoft starter for asynchronous motor

Altistart 01, Soft starter for asynchronous motor, ATS01, 3 A-110..480V-0.55..1.1 KW

Item Number: ATS01N103FT

Datasheet

Product Dimensions

Width icon

Width23 mm

Height icon

Height100 mm

Depth icon

Depth100 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Altistart 01

Product or component type

soft starter

Product destination

asynchronous motors

Warranty

18 months

Physical

Function available

integrated bypass

Marking

CE

Height

100 mm

Width

23 mm

Depth

100 mm

Net weight

0.16 kg

Standards

EN/IEC 60947-4-2

Product certifications

CSA|GOST|C-Tick|UL|CCC

Ip degree of protection

IP20

Relative humidity

5...95 % without condensation or dripping water conforming to EN/IEC 60068...2-3

Ambient air temperature for operation

-10...40 °C (without derating)|40...50 °C (with current derating of 2 % per °C)

Ambient air temperature for storage

-25...70 °C conforming to EN/IEC 60947...4-2

Reach regulation

Free of Substances of Very High Concern above the threshold

Reach free of svhc

Yes

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

California proposition 65

"WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"

Others

Life cycle assessment data

No

If one of the deliverables is not relevant please give the reason

Brand Labelling

Substance regulation data deliverable

Yes

Package 1 bare product quantity

1

Package 2 bare product quantity

36

Product specific application

simple machine

Device short name

ATS01

Network number of phases

1 phase

[us] rated supply voltage

110...480 V - 10...10 %

Motor power kw

0.37 kW, 3 phases at 230 V|0.55 kW, 3 phases at 230 V|1.1 kW, 3 phases at 400 V|0.37 kW, 1 phase at 230 V

Motor power hp

0.5 hp, 3 phases at 230 V|0.5 hp, 3 phases at 460 V|1.5 hp, 3 phases at 460 V

Icl starter rating

3 A

Utilisation category

AC-53B conforming to EN/IEC 60947-4-2

Current consumption

15 A at nominal load

Type of start

start with voltage ramp

Power dissipation in w

19 W in transient state|4 W at full load and at end of starting

Assembly style

with heat sink

Supply voltage limits

99...528 V

Supply frequency

50...60 Hz - 5...5 %

Network frequency

47.5...63 Hz

Output voltage

<= power supply voltage

[uc] control circuit voltage

110 V AC +/- 10 % at 30 mA|24 V AC/DC +/- 10 % at 25 mA|240 V AC +/- 10 % at 65 mA

Starting time

1 s / 100 |5 s / 20 |adjustable from 1 to 5 s

Starting torque

30...80 % of starting torque of motor connected directly on the line supply

Discrete output current

2 A DC-13|3 A AC-15

Tightening torque

0.8...0.8 N.m

Electrical connection

cage type connector - rigid 1 2.5 mm² AWG 14 control circuit|cage type connector - rigid with cable end 1 2.5 mm² AWG 14 power circuit|cage type connector - rigid without cable end 2 1 mm² AWG 17 control circuit|cage type connector - rigid without cable end 2 1 mm² AWG 17 power circuit|cage type connector - flexible with cable end 1 2.5 mm² AWG 14 control circuit|cage type connector - flexible with cable end 1 2.5 mm² AWG 14 power circuit|cage type connector - flexible without cable end 1 2.5 mm² AWG 14 control circuit|cage type connector - flexible without cable end 1 2.5 mm² AWG 14 power circuit|cage type connector - flexible with cable end 2 0.75 mm² AWG 18 control circuit|cage type connector - flexible with cable end 2 0.75 mm² AWG 18 power circuit|cage type connector - flexible without cable end 2 1 mm² AWG 17 control circuit|cage type connector - flexible without cable end 2 1 mm² AWG 17 power circuit

Operating position

vertical +/- 10 degree

Compatibility code

ATS01N1

Power range

0.5 kW at 200...240 V 1 phase|0.5 kW at 200...240 V 3 phases|0.55...1 kW at 200...240 V 3 phases|1.1...2 kW at 380...440 V 3 phases

Motor starter type

soft starter

Electromagnetic compatibility

conducted and radiated emissions level B conforming to CISPR 11|conducted and radiated emissions level B conforming to IEC 60947-4-2|damped oscillating waves level 3 conforming to IEC 61000-4-12|electrostatic discharge level 3 conforming to IEC 61000-4-2|EMC immunity level 3 conforming to EN 50082-1|EMC immunity level B conforming to EN 50082-2|harmonics level 3 conforming to IEC 1000-3-2|harmonics level 3 conforming to IEC 1000-3-4|immunity to conducted interference caused by radio-electrical fields level 3 conforming to IEC 61000-4-6|immunity to electrical transients level 4 conforming to IEC 61000-4-4|immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3|micro-cuts and voltage fluctuation conforming to IEC 61000-4-11|voltage/current impulse level 3 conforming to IEC 61000-4-5

Pollution degree

2 conforming to EN/IEC 60947-4-2

Vibration resistance

1 gn (f= 13-150 Hz) conforming to EN/IEC 60068-2-6|1.5 mm peak to peak (f= 3-13 Hz) conforming to EN/IEC 60068-2-6

Shock resistance

15 gn for 11 ms conforming to EN/IEC 60068-2-27

Operating altitude

<= 1000 m without derating|> 1000 m with current derating of 2.2 % per additional 100 m

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

2.500 cm

Package 1 width

10.300 cm

Package 1 length

10.500 cm

Package 1 weight

172.000 g

Unit type of package 2

S02

Number of units in package 2

36

Package 2 height

15.000 cm

Package 2 width

30.000 cm

Package 2 length

40.000 cm

Package 2 weight

6.491 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • End of Life Manual

  • Technical Drawing

  • Certificates (MSDS)

  • Declaration of Conformity

  • eTechPub

Frequently Asked Questions

hide show

Does the ATS01 come with a shorting contactor?

Issue:
Does the ATS01 have an internal shorting contactor?

Product Line:
Altistat 01

Environment:
All

Cause:
N/A

Resolution:
All of the ALTISTART 01 models, except the ATS01N103FT and ATS01N106FT, have an internal shorting contactor as standard.

What is the combination SCCR rating for ATSU01 with the U-Line starters?

Issue:
Customer is using the ATSU01 with the mounted Tesys U-Line motor starter. They are looking to coordinate the short circuit current rating.

Product line:
ATSU01, U-Line, Altistart 01, ATS01

Environment:
All models.

Cause:
n/a

Resolution:
Per Product Marketing, we do not have any combination SCCR ratings for the ATSU01 and U-Line devices. The ATSU01 and ATS01 have a standalone rating of 5kA. Except the ATS01N103FT and ATS01N106FT, which are 1kA. 
 

What are the adjustment ranges for the dials on an ATS01N1..FT?

What are the adjustment ranges for the dials on an ATS01N1..FT?  

Issue : 
Adjustment ranges for Schneider-Electric recommend for Altistart Soft Starters?

Product Line : 
Altistart Soft Starters

Environment : 
Open style Soft Starters

Cause : 
Adjustment Range

Resolution : 
For the START TIME dial, setpoint A is 1second and setpoint E is 5seconds.  There is a linear relationship from A to E setpoints.
For the INITIAL VOLTAGE dial, setpoint A is 30% and setpoint E is 80% of full voltage.  There is a linear relationship from A to E setpoints.