Medilec, Amber Power, Available Neon with F30Z1.5 Mounting Clip

Medilec, Amber Power, Available Neon with F30Z1.5 Mounting Clip

Item Number: N01

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

ESP Metal Plate Series

Physical

[ue] rated operational voltage

240 V AC

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Package 1 bare product quantity

1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3.0 cm

Package 1 width

3.0 cm

Package 1 length

3.0 cm

Package 1 weight

11.0 g
Show all specifications

Frequently Asked Questions

hide show

Video: What auxiliary contact modules are available for the LC1D and LC2D contactors?

Issue:
Auxiliary contact modules for the LC1D and LC2D contactors

Product Line: 
Contactor and Starters - IEC

Environment:
North American Products

Resolution:
Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
Front Mounting; maximum of 1 block per contactor:

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1---------LADN11-----------LA1DN11
--1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
--1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
--2-----------0---------LADN20-----------LA1DN20
--2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
--2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
--0-----------2---------LADN02-----------LA1DN02
--2-----------2---------LADN22-----------LA1DN22
--2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
--2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
--2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
--3-----------1---------LADN31------------LA1DN31
--3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
--1-----------3---------LADN13------------LA1DN13
--4-----------0---------LADN40------------LA1DN40
--4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
--0-----------4---------LADN04------------LA1DN04




Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------0--------LADN10----------LA1DN10
--0-----------1--------LADN01----------LA1DN01

Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
(*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.

N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1--------LAD8N11----------LA8DN11
--2-----------0--------LAD8N20----------LA8DN20
--0-----------2--------LAD8N02----------N/A

Footnotes:
{1.EN_US} EN50 012 Machine Tool Terminal Markings
{2.EN_US} (2) NO Sealed Dust Tight Contacts
{3.EN_US} Gold Flash Contacts
{4.EN_US} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
{5.EN_US} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
{6.EN_US} (2) NO Dust Tight Contacts & (2) NO Standard Contacts

Is there a thru the door external operator for the GV2ME and GV2P manual starters?

Issue:
What is the through-the-door operating mechanism for a GV2 Manual starter?

Product Line: 
Digest 177 Section 18 : Contactors and Starters - IEC

Environment:
North American Products

Cause:
Needs  the through-the-door operating mechanism for a GV2P Manual starter

Resolution:
There are no available kits for the GV2ME devices, only the GV2P devices (as listed below)
GV2APN01 - Nema 1 Black
GV2APN02 - Nema 1, 12 Red/Yellow
GV2APN04 - Nema 3R, 4, 4X Red/Yellow
 

Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

ISSUE
In which contactors can the LA1DN and LADN auxiliary contacts be mounted?

PRODUCT LINE
Auxiliary contacts for the Tesys D line

ENVIRONMENT
Tesys D-Line and Tesys F

RESOLUTION
These contacts will only fit on the following contactors:
Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
Left side mount only to LC1F contactors

GV2P disconnect options

Issue:
What is the product number for a complete through-the-door disconnect device for a GV2P

Product Line:
IEC Contactors and Starters

Environment:
GV2P Manual Starters and Protectors

Resolution:
There are three devices which include mechanism, shaft and handle:
GV2APN01 has a NEMA 1, 12 rating and is black
GV2APN02 has a NEMA 1, 12 rating and is red/yellow
GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

Will a single circuit auxiliary contact block, like a LADN10 or LADN01, fit onto the Tesys D09-D38 amp contactors?

Issue:
Identifying auxiliary contact blocks for Tesys D contactors

Product Line:
IEC contactors and starters

Environment:
Tesys D Auxiliary contact blocks

Cause:
single auxiliary contact block needed for use on a Tesys D line contactor

Resolution:
No, the single pole contact block will not fit . A LADN11,LADN20, LADN02 etc will fit. Anything with 2 auxiliary contacts in one block will fit.