Datasheet
Close
Specifications
Design
Range of product
Series 900|PDL
Product brand
Clipsal
Colour
white
Physical
[in] rated current
10 A
[ue] rated operational voltage
230 V 50/60 Hz conforming to EN 60309-2
Others
Voltage colour
blue
Plug, socket, control station shape
angled
Duration
6 h
Unit type of package 1
PCE
Number of units in package 1
1
Frequently Asked Questions
hide show
Issue:
Can new accessories be used on older style contactors
Product Line:
IEC contactors and starters
Environment:
Pre-Tesys Contactors
Cause:
Identifying product compatibility
Resolution:
Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.
Can new accessories be used on older style contactors
Product Line:
IEC contactors and starters
Environment:
Pre-Tesys Contactors
Cause:
Identifying product compatibility
Resolution:
Yes, all front mount D2 and Tesys series auxiliary modules are backward forward compatible.
Issue:
Auxiliary contact modules for the LC1D and LC2D contactors
Product Line:
Contactor and Starters - IEC
Environment:
North American Products
Resolution:
Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
Front Mounting; maximum of 1 block per contactor:
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1---------LADN11-----------LA1DN11
--1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
--1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
--2-----------0---------LADN20-----------LA1DN20
--2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
--2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
--0-----------2---------LADN02-----------LA1DN02
--2-----------2---------LADN22-----------LA1DN22
--2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
--2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
--2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
--3-----------1---------LADN31------------LA1DN31
--3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
--1-----------3---------LADN13------------LA1DN13
--4-----------0---------LADN40------------LA1DN40
--4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
--0-----------4---------LADN04------------LA1DN04
Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------0--------LADN10----------LA1DN10
--0-----------1--------LADN01----------LA1DN01
Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
(*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1--------LAD8N11----------LA8DN11
--2-----------0--------LAD8N20----------LA8DN20
--0-----------2--------LAD8N02----------N/A
Footnotes:
{1.EN_US} EN50 012 Machine Tool Terminal Markings
{2.EN_US} (2) NO Sealed Dust Tight Contacts
{3.EN_US} Gold Flash Contacts
{4.EN_US} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
{5.EN_US} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
{6.EN_US} (2) NO Dust Tight Contacts & (2) NO Standard Contacts
Auxiliary contact modules for the LC1D and LC2D contactors
Product Line:
Contactor and Starters - IEC
Environment:
North American Products
Resolution:
Select based on application requirements. Please note that the TeSys and Pre-TeSys auxiliary blocks are backward/forward compatible.
Front Mounting; maximum of 1 block per contactor:
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1---------LADN11-----------LA1DN11
--1-----------1---------LADN11G---------LA1DN11G (See Footnote 1)
--1-----------1---------LADN11P---------LA1DN11P (See Footnote 1)
--2-----------0---------LADN20-----------LA1DN20
--2-----------0---------LA1DX20---------LA1DX20 (See Footnote 2)
--2-----------0---------LA1DY20---------LA1DY20 (See Footnote 3)
--0-----------2---------LADN02-----------LA1DN02
--2-----------2---------LADN22-----------LA1DN22
--2-----------2---------LADN22G---------LA1DN22G (See Footnote 1)
--2-----------2---------LADN22P---------LA1DN22P (See Footnote 1)
--2-----------2---------LADC22------------LA1DC22 (See Footnote 4)
--3-----------1---------LADN31------------LA1DN31
--3-----------1---------LA1DZ31----------LA1DZ31 (See Footnote 5)
--1-----------3---------LADN13------------LA1DN13
--4-----------0---------LADN40------------LA1DN40
--4-----------0---------LA1DZ40-----------LA1DZ40 (See Footnote 6)
--0-----------4---------LADN04------------LA1DN04
Front Mounting; maximum of 1 block per contactor: For use with D2 Series 25 amp through 80 amp contactors and TeSys Series 40 amp through 80 amp only.
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------0--------LADN10----------LA1DN10
--0-----------1--------LADN01----------LA1DN01
Side Mounting; maximum of 1 block on each side for D2 Series and Tesys Series 40 through 80 amp contactors. Tesys 9 through 32, 115, and 150 amps contactors will accept 1 block and is limited to left side only. (*) DC control devices will not accept side mount auxiliaries.
(*) DC control exceptions that will accept one left side mounted auxiliary: LC1D115 & LC1D150.
N.O.-------N.C.-----TeSys P/N--------Pre-TeSys P/N
--1-----------1--------LAD8N11----------LA8DN11
--2-----------0--------LAD8N20----------LA8DN20
--0-----------2--------LAD8N02----------N/A
Footnotes:
{1.EN_US} EN50 012 Machine Tool Terminal Markings
{2.EN_US} (2) NO Sealed Dust Tight Contacts
{3.EN_US} Gold Flash Contacts
{4.EN_US} (1) NO & (1) NC Standard and (1) NO & (1) NC Make Before Break
{5.EN_US} (2) NO Dust Tight Contacts & (1) NO & (1) NC Standard Contacts
{6.EN_US} (2) NO Dust Tight Contacts & (2) NO Standard Contacts
Issue:
Replacement NEMA 3R enclosure for a 9013FSW or 9013FYW.
Product Line:
Pressure, Vacuum, and Float Switches
Environment:
9013 Type F Pressure Switches
Resolution:
These are not available as a repair part. Replace the entire switch.
Replacement NEMA 3R enclosure for a 9013FSW or 9013FYW.
Product Line:
Pressure, Vacuum, and Float Switches
Environment:
9013 Type F Pressure Switches
Resolution:
These are not available as a repair part. Replace the entire switch.
Issue:
Contact Rating of 9013F Pressure Switches
Product Line:
Pressure, vacuum and Float Switches
Environment:
9013 Type F Pressure Switch
Resolution:
Those contacts have a control circuit rating of A600.
They are DC rated at 1/4 HP at 115V and 230V (Except form M4)
They are Single Phase AC rated 1 1/2 HP at 115V, 2 HP at 230V
They are Polyphase rated 2 HP at 115V, 3 HP at 230V, and 1 HP at 460/575V.
This also applies to the 9013 FHG2, 9, 12, 13, 44, 49 9013 FSG, and FSW.
Contact Rating of 9013F Pressure Switches
Product Line:
Pressure, vacuum and Float Switches
Environment:
9013 Type F Pressure Switch
Resolution:
Those contacts have a control circuit rating of A600.
They are DC rated at 1/4 HP at 115V and 230V (Except form M4)
They are Single Phase AC rated 1 1/2 HP at 115V, 2 HP at 230V
They are Polyphase rated 2 HP at 115V, 3 HP at 230V, and 1 HP at 460/575V.
This also applies to the 9013 FHG2, 9, 12, 13, 44, 49 9013 FSG, and FSW.
Issue:
Is the 9013F compatible with Skydrol?
Product Line:
Pressure switches
Environment:
9013F
Cause:
Material comparability
Resolution:
It is not recommended for Skydrol. Nitrile is the standard material used in diaphragm for the 9013F devices. The 9012G has an option to use ethylene propylene, form Q3, for the diaphragm.
Note that 9012G switches are control devices and cannot support inductive loads directly, but require an interposing contactor.
Is the 9013F compatible with Skydrol?
Product Line:
Pressure switches
Environment:
9013F
Cause:
Material comparability
Resolution:
It is not recommended for Skydrol. Nitrile is the standard material used in diaphragm for the 9013F devices. The 9012G has an option to use ethylene propylene, form Q3, for the diaphragm.
Note that 9012G switches are control devices and cannot support inductive loads directly, but require an interposing contactor.
Issue:
9012GAW4 B4: What does the B4 stand for?
Product Line:
Pressure Switches
Environment:
Class 9012
Cause:
Product features and nomenclature.
Resolution:
The form B4 is no longer available for the above pressure switch. However, it was for a detachable bottom conduit hub.
9012GAW4 B4: What does the B4 stand for?
Product Line:
Pressure Switches
Environment:
Class 9012
Cause:
Product features and nomenclature.
Resolution:
The form B4 is no longer available for the above pressure switch. However, it was for a detachable bottom conduit hub.
Issue:
What is the temperature rating of a 9013FSG2J20? Will it work in hot water at 140 F?
Product Line:
Pressure Switches
Environment:
Pressure switches commercialized in the US
Cause:
What is the temperature rating of a 9013FSG2J20? Will it work in hot water at 140 F?
Resolution:
The Media temperature for all 9013 F & G switches is minimum -30C (-22F) and maximum 125C (257F).
The ambient temperature is a minimum of -30C (-22F) and a maximum of 70C (158F).
What is the temperature rating of a 9013FSG2J20? Will it work in hot water at 140 F?
Product Line:
Pressure Switches
Environment:
Pressure switches commercialized in the US
Cause:
What is the temperature rating of a 9013FSG2J20? Will it work in hot water at 140 F?
Resolution:
The Media temperature for all 9013 F & G switches is minimum -30C (-22F) and maximum 125C (257F).
The ambient temperature is a minimum of -30C (-22F) and a maximum of 70C (158F).
Issue:
How do I lift a Masterpact NW breaker? What are the cross bar and lifting hook part numbers?
Product Line:
Masterpact NW
Resolution:
You will need a cross bar depending on the frame, a kit of lifting hooks, and a lifting truck or hoist provided by yourself:
Crossbar for W-Frame Circuit Breaker or Cradle - S48900
Crossbar for Y-Frame Circuit Breaker or Cradle - S48901
Set of Two Lifting Hooks - S48906
How do I lift a Masterpact NW breaker? What are the cross bar and lifting hook part numbers?
Product Line:
Masterpact NW
Resolution:
You will need a cross bar depending on the frame, a kit of lifting hooks, and a lifting truck or hoist provided by yourself:
Crossbar for W-Frame Circuit Breaker or Cradle - S48900
Crossbar for Y-Frame Circuit Breaker or Cradle - S48901
Set of Two Lifting Hooks - S48906
Issue:
Type F pressure switch came with Form X - can he bypass that pressure release valve
Product Line:
Pressure, Vacuum, and Float Switches
Environment:
9013 Type F Pressure Switches
Resolution:
Just do not hook anything to it - Form X is just a mechanical bleed valve.
Type F pressure switch came with Form X - can he bypass that pressure release valve
Product Line:
Pressure, Vacuum, and Float Switches
Environment:
9013 Type F Pressure Switches
Resolution:
Just do not hook anything to it - Form X is just a mechanical bleed valve.
Issue:
Factory setting tolerance for type G pressure switch
Product Line:
Pressure, Vacuum, and Float Switches
Environment:
Class 9013 Type G Pressure Switches
Resolution:
Factory setting tolerance is + 4 psi.
Factory setting tolerance for type G pressure switch
Product Line:
Pressure, Vacuum, and Float Switches
Environment:
Class 9013 Type G Pressure Switches
Resolution:
Factory setting tolerance is + 4 psi.
Issue:
9013FHG pressure switch repair kit
Product Line:
Commercial Pressure Switches
Environment:
Type F—Pumptrol™ Water Pump Pressure Switches
Resolution:
For standard (non-special) devices:
9013FHG pressure switch repair kit
Product Line:
Commercial Pressure Switches
Environment:
Type F—Pumptrol™ Water Pump Pressure Switches
Resolution:
For standard (non-special) devices:
- Types FHG2 thru 19 order 9998 PC241.
- Types FHG22 thru 39 order 9998 PC242.
- Types FHG42 thru49 order 9998 PC241.
- Types FHG52 thru 59 order 9998 PC242.
Issue:
replacement contact/diaphragm kit for 9013GHG2
Product Line:
Pressure, Vaccum and Float Switches
Environment:
9013 Float Switches
Resolution:
9998PC205 is the contacts only for All 9013 GHG except with Forms H( NO and NC) and R (Reverse action). ONLY means alone and that no other parts are included.
The Diaphragm assy would be part number 9998PC208. The diaphram is a mechanical acutating mechanism which has no electrical components in it as it is shipped.
replacement contact/diaphragm kit for 9013GHG2
Product Line:
Pressure, Vaccum and Float Switches
Environment:
9013 Float Switches
Resolution:
9998PC205 is the contacts only for All 9013 GHG except with Forms H( NO and NC) and R (Reverse action). ONLY means alone and that no other parts are included.
The Diaphragm assy would be part number 9998PC208. The diaphram is a mechanical acutating mechanism which has no electrical components in it as it is shipped.