Item Number: A9V02763

Datasheet

Product Dimensions

Width icon

Width108 mm

Height icon

Height91 mm

Depth icon

Depth73.5 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Acti9

Range of product

iC60

Product or component type

add-on residual current devices

Product compatibility

single terminal

Warranty

18 months

Physical

[in] rated current

63 A

[ue] rated operational voltage

400...415 V AC 50/60 Hz conforming to EN/IEC 61009-1|400...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1

Standards

EN/IEC 61009-1|EN/IEC 61009-2-1

Range compatibility

Acti 9 Acti9 iC60

Local signalling

trip indicator

Mounting mode

clip-on

Mounting support

DIN rail

Height

91 mm

Width

108 mm

Depth

73.5 mm

Net weight

0.245 kg

Connections - terminals

tunnel type terminal downside for 1 cable(s) 1-35 mm² rigid without cable end|tunnel type terminal downside for 1 cable(s) 1-25 mm² flexible without cable end|tunnel type terminal downside for 1 cable(s) 1-25 mm² flexible with cable end

Wire stripping length

14 mm for bottom connection

Ip degree of protection

IP20 conforming to IEC 60529|IP40 (modular enclosure) conforming to IEC 60529

Ambient air temperature for operation

-25...60 °C

Ambient air temperature for storage

-40...85 °C

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Rohs exemption information

Yes

Environmental disclosure

ENVPEP1409017EN

Circularity profile

N/A

Others

Package 1 bare product quantity

1

Device short name

Vigi iC60

Poles description

3P + N

Neutral position

left

Earth-leakage sensitivity

30 mA

Earth-leakage protection time delay

instantaneous

Earth-leakage protection class

type A

Network type

AC

Network frequency

50/60 Hz

9 mm pitches

6

Device location in system

outgoer

Residual current tripping technology

voltage independent

[ui] rated insulation voltage

500 V AC 50/60 Hz conforming to IEC 60947-2

[uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-2

Electrical connection to mcb

by screws

Comb busbar and distribution block compatibility

bottom: YES

Total power losses

6.9 W

Power losses per pole

2.3 W

Tightening torque

3.5...3.5 N.m bottom

Pollution degree

3 conforming to IEC 60947-2

Electromagnetic compatibility

8/20 µs impulse withstand, 250 A conforming to IEC 61009-1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

8.5 cm

Package 1 width

11.5 cm

Package 1 length

14.5 cm

Package 1 weight

296.0 g

Unit type of package 2

S03

Number of units in package 2

15

Package 2 height

30.0 cm

Package 2 width

30.0 cm

Package 2 length

40.0 cm

Package 2 weight

4.895 kg

Scip number

71855c1e-69ad-4100-93ab-1a7795ea517c

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Halogen content performance

Halogen free plastic parts product

Halogen content performance

Halogen free plastic parts product

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Carbon footprint (kg.eq.co2 per cr, total life cycle)

8.44734213202996
Show all specifications

Frequently Asked Questions

hide show

What is the part code for a 3 Phase 32A 30mA RCBO?

We do not offer a single 3 Pole 32 Amps 30mA RCBO. 

You can use 3 Pole 32 Amps iC60 MCB and connect it with the 3 Pole Add-on Vigi Module "A9V02763" (comes with the neutral tail to be connected with the distributed neutral) - this combination is 6 Poles wide 

If balanced three phase system with out neutral you should use Add on Vigi "A9V51363" - this combination is 6½ Pole wide

Acti 9 iC60 3 Phase 30mA Type A RCBO available in Australia ?

Acti 9 3phase RCBOs available in Australia, are made by combining the breaker and add-on RCD module (Vigi block).

For example: 3 pole 10A 30mA RCBO is a 3 pole 10A breaker + 30mA Add-on Vigi block.
A9F44310 (3P 10A C curve iC60 breaker, 6kA) + A9V02763 (63A 30mA earth leakage add-on block 3P+N with neutral wire)

3P 10A 30mA RCBO for balanced load will be,
A9F44310 (3P 10A C curve iC60 breaker, 6kA) + A9V51363 (63A 30mA earth leakage add-on block 3P without neutral)

Vigi.png

The datasheets are in available in the link below.
A9V02763https://www.se.com/au/en/product/A9V02763/vigi-ic60---earth-leakage-add-on-block---3p-%2B-n---63a---30ma---a-type/
A9V51363 – https://www.se.com/au/en/product/A9V51363/vigi-ic60---earth-leakage-add-on-block---3p---63a---30ma---a-type/
Acti 9 Technical Catalogue – https://www.se.com/au/en/download/document/SAUM9XED1130718/