Item Number: 755PFM4

755PFM4 is a photoelectric flush mount smoke alarm that can be used as a single mains powered battery backed alarm or can be interconnected with other 755 series smoke alarms. The stylish design is extremely low profile and unobtrusive. It caters for fast installs with 90mm cut out & extra large terminals.

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Free Introductory Training Module

On installation, maintenance and troubleshooting

Home owner checking their fire alarm
Clipsal Firetek group shot of products and packaging
dimensions

Specifications

Design

Range

Fire Tek

Product brand

Clipsal

Product or component type

smoke detector

Device application

early detection of smouldering fires and open fires

Sustainable offer status

Green Premium product

Physical

Type of packing

carton

Supply

mains

[in] rated current

13 µA at 9 V, DC not in operation| 40 mA at 9 V, DC operation

Function available

local alarm| hush function| self-test of smoke detection

Control type

button (test/hush function)

Local signalling

sound: signal|visual: LED (red) for warning and low battery|visual: LED (green) for ON status

Connections - terminals

screw terminal (line) - 2 x 1...3 x 2.5 mm²|screw terminal (neutral) - 2 x 1...3 x 2.5 mm²|screw terminal (earth loop) - 2 x 1...3 x 2.5 mm²|screw terminal (interconnect) - 2 x 1...3 x 2.5 mm²

Type of installation

indoor

Device mounting

flush

Mounting support

ceiling

Fixing mode

by screws

Depth

102.6 mm

Net weight

263 g

Ip degree of protection

IP20

Ambient air temperature for operation

0...45 °C

Ambient air temperature for storage

-20...60 °C

Relative humidity

5...95 %

Product certifications

RCM|SAI|Activfire

Standards

ISO 8201|AS 3786:2014|AS/NZS 60950.1|AS/NZS 60065

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP1907002EN

Circularity profile

ENVEOLI1907002EN

Material

Device composition

1 mounting base|1 dust protection foil|1 user guide|3 screws|1 sticker sheet

Material

thermoplastic

Others

Package 1 bare product quantity

1

Electronic sensor type

photo-electric sensor

[us] rated supply voltage

220...240 V AC 50 Hz

Battery type

alkaline 9 V 6LR61

Battery life

1 year(s)

Output voltage limits

interconnection: 6.5...20 V

Type of alarms

low battery at 6.9...7.5 V

Detection type

heat

Technology type

scattered light (Tyndall effect)

Type of measurement

optic

Number of devices

40 for wired alarm wired over <= 150 m

Noise level

85 dB at 3 m, minimum

Diameter

108 mm

Projecting depth

23 mm

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

10.6 cm

Package 1 width

14.5 cm

Package 1 length

14.5 cm

Package 1 weight

343 g
Show all specifications

Frequently Asked Questions

hide show

What causes the smoke alarm to continuously beep ?

The dust inside the smoke alarms can cause a continuous beep.
Please follow the regular maintenance check to avoid this.

Vacuum the smoke alarms using a soft brush attachment-
Keeping your smoke alarm free of dust particles, dirt, kitchen grease or cobwebs will help you reduce false alarms and ensure any smoke can easily reach the internal sensing chamber.

Clean and wipe down around unit-
Clean around the smoke alarm unit and remove any insects or other contamination which may have occurred. Spray bug repellent on a cloth and wipe the ceiling around the smoke alarm to act as a future bug deterrent. Clean every 3-6 months to mitigate insect ingress.

ALWAYS TEST THE SMOKE ALARM AFTER CLEANING.

Attached is the Clipsal smoke alarm troubleshooting guide for more info.

Clipsal Smoke Alarms.png
 
Firetek group shot

Range

Clipsal's Fire Tek range helps protect the most valuable assets; family, friends and the home.

They are backed by the SAI Global 5 ticks certification of quality, offering robust designs for reliability, ensuring early detection and warning from hazardous smoke and fire.

The Australian Building Code mandates all new homes must have AS3786:2014 compliant smoke alarms installed, interconnected and hard wired to mains power.

By having Fire Tek's smoke alarms installed, you will have the best chance of escaping the devastating effects of a house fire.

Visit our Smoke Alarms FAQ page

To learn more