Altivar 12, Variable speed drive ATV12, 2.2kW, 3hp, 200..240V, 1ph, with heat sink

Home ProductsIndustrialAltivarVariable speed drive ATV12

Altivar 12, Variable speed drive ATV12, 2.2kW, 3hp, 200..240V, 1ph, with heat sink

Item Number: ATV12HU22M2

Datasheet

Product Dimensions

Width icon

Width105 mm

Height icon

Height142 mm

Depth icon

Depth156.2 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Altivar 12

Product or component type

variable speed drive

Warranty

18 months

Physical

Mounting mode

cabinet mount

Communication port protocol

Modbus

Ip degree of protection

IP20

Connector type

1 RJ45

Protection type

line supply overvoltage|line supply undervoltage|overcurrent between output phases and earth|overheating protection|short-circuit between motor phases|against input phase loss in three-phase|thermal motor protection via the drive by continuous calculation of I²t

Quantity per set

set of 1

Width

105 mm

Height

142 mm

Depth

156.2 mm

Net weight

1.4 kg

Product certifications

NOM|CSA|C-Tick|UL|GOST|RCM|KC

Marking

CE

Standards

UL 508C|UL 618000-5-1|IEC 61800-5-1|IEC 61800-3

Ambient air temperature for operation

-10...60 °C

Relative humidity

5...95 % without condensation conforming to IEC 60068...2-3|5...95 % without dripping water conforming to IEC 60068...2-3

Ambient air temperature for operation

-10...50 °C without derating|50...60 °C with current derating 2.2 % per °C

Ambient air temperature for storage

-25...70 °C

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

California proposition 65

"WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"

Others

Life cycle assessment data

No

If one of the deliverables is not relevant please give the reason

End of commercialization (planned, announced or effective)

Substance regulation data deliverable

Yes

Package 1 bare product quantity

1

Package 2 bare product quantity

30

Product specific application

simple machine

Design of frequency changer

U converter

Supply frequency

50/60 Hz +/- 5 %

[us] rated supply voltage

200...240 V - 15...10 %

[us] rated supply voltage

200...240 V

Relative symmetric mains voltage tolerance

10 %

Nominal output current

10 A

Number of input phases

3

Number of output phases

3

Motor power hp

3 hp

Motor power kw

2.2 kW

Motor power hp

3 hp

Emc filter

integrated

Discrete input number

4

Discrete output number

2

Analogue input number

1

Analogue output number

1

Relay output number

1

Number of inputs, bidirectional, not potential-free

0

Number of inputs, potential-free

0

Computer port

true

Optical interface present

false

Physical interface

2-wire RS 485

Continuous output current

10 A at 4 kHz

Method of access

server Modbus serial

Speed drive output frequency

0.5...400 Hz

Speed range

1...20

Sampling duration

20 ms, tolerance +/- 1 ms for logic input|10 ms for analogue input

Linearity error

+/- 0.3 % of maximum value for analogue input

Frequency resolution

analog input: converter A/D, 10 bits|display unit: 0.1 Hz

Time constant

20 ms +/- 1 ms for reference change

Transmission rate

9.6 kbit/s|19.2 kbit/s|38.4 kbit/s

Transmission frame

RTU

Number of addresses

1...247

Data format

8 bits, configurable odd, even or no parity

Communication service

read holding registers (03) 29 words|write single register (06) 29 words|write multiple registers (16) 27 words|read/write multiple registers (23) 4/4 words|read device identification (43)

Type of polarization

no impedance

Number of hw interfaces parallel

0

Number of hw interfaces industrial ethernet

0

Number of hw interfaces profinet

0

Number of hw interfaces serial rs232

0

Number of hw interfaces serial rs422

0

Number of hw interfaces serial rs485

1

Number of hw interfaces serial tty

0

Number of hw interfaces usb

0

Number of hw interfaces other

0

Supporting protocol for as-interface safety at work

false

Supporting protocol for asi

false

Supporting protocol for suconet

false

Supporting protocol for bacnet

false

Supporting protocol for can

false

Supporting protocol for data-highway

false

Supporting protocol for devicenet

false

Supporting protocol for devicenet safety

false

Supporting protocol for ethernet/ip

false

Supporting protocol for foundation fieldbus

false

Supporting protocol for interbus

false

Supporting protocol for interbus-safety

false

Supporting protocol for knx

false

Supporting protocol for lon

false

Supporting protocol for modbus

true

Supporting protocol for other bus systems

false

Supporting protocol for profibus

false

Supporting protocol for profinet cba

false

Supporting protocol for profinet io

false

Supporting protocol for profisafe

false

Supporting protocol for safetybus p

false

Supporting protocol for sercos

false

Supporting protocol for tcp/ip

false

4 quadrant operation possible

false

Asynchronous motor control profile

sensorless flux vector control|quadratic voltage/frequency ratio|voltage/frequency ratio (V/f)

Maximum output frequency

4 kHz

Transient overtorque

150...170 % of nominal motor torque depending on drive rating and type of motor

Acceleration and deceleration ramps

linear from 0 to 999.9 s|U|S

Motor slip compensation

adjustable|preset in factory

Switching frequency

2...16 kHz adjustable|4...16 kHz with derating factor

Nominal switching frequency

4 kHz

Braking to standstill

by DC injection

Brake chopper integrated

false

Maximum associated fuse rating

12.5 A

Line current

24.0 A at 100 V (heavy duty)|20.2 A at 120 V (heavy duty)

Maximum output voltage

240 V

Nominal output power

2200.0 W

Apparent power

4.8 kVA at 240 V (heavy duty)

Maximum transient current

15.0 A during 60 s (heavy duty)|16.5 A during 2 s (heavy duty)

Capacity of dc link

1890.0 µF

Network frequency

50...60 Hz

Relative symmetric network frequency tolerance

5 %

Prospective line isc

1 kA

1 phase low current possible

false

Base load current at high overload

10.0 A

Application in domestic and commercial area permitted

false

Application in industrial area permitted

true

Emc limit value (complied)

true

Power loss per device current dependent

93.0 W

Power loss static current independent

11.0 W

Power dissipation in w

forced cooling: 93.0 W

Housing material

plastic

With safety function safely limited speed (sls)

false

With safety function safe brake management (sbc/sbt)

false

With safety function safe operating stop (sos)

false

With safety function safe position (sp)

false

With safety function safe programmable logic

false

With safety function safe speed monitor (ssm)

false

With safety function safe stop 1 (ss1)

false

With sft fct safe stop 2 (ss2)

false

With safety function safe torque off (sto)

false

With safety function safely limited position (slp)

false

With safety function safe direction (sdi)

false

Operating element present

true

Tightening torque

1.2 N.m

Insulation

electrical between power and control

Operating altitude

> 1000...2000 m with current derating 1 % per 100 m|<= 1000 m without derating

Operating position

vertical +/- 10 degree

Assembly style

with heat sink

Electromagnetic compatibility

electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4|electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2|immunity to conducted disturbances level 3 conforming to IEC 61000-4-6|radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3|surge immunity test level 3 conforming to IEC 61000-4-5|voltage dips and interruptions immunity test conforming to IEC 61000-4-11

Environmental class (during operation)

class 3C3 according to IEC 60721-3-3|class 3S2 according to IEC 60721-3-3

Environmental class (during storage)

class 1C3 according to IEC 60721-3-1|class 1S2 according to IEC 60721-3-1

Environmental class (during transport)

class 2C3 according to IEC 60721-3-2|class 2S1 according to IEC 60721-3-2

Maximum acceleration under shock impact (during operation)

150 m/s² at 11 ms

Maximum acceleration under shock load (during storage)

150 m/s² at 11 ms

Maximum acceleration under shock load (during transport)

150 m/s² at 11 ms

Maximum acceleration under vibratory load (during storage)

10 m/s² at 13...200 Hz

Maximum acceleration under vibratory load (during transport)

10 m/s² at 13...200 Hz

Maximum acceleration under vibrational stress (during operation)

10 m/s² at 13...200 Hz

Maximum deflection under vibratory load (during storage)

1.5 mm at 2...13 Hz

Maximum deflection under vibratory load (during transport)

1.5 mm at 2...13 Hz

Maximum deflection under vibratory load (during operation)

1.5 mm at 2...13 Hz

Volume of cooling air

16 m3/h

Overvoltage category

class III

Regulation loop

adjustable PID regulator

Electromagnetic emission

radiated emissions environment 1 category C2 conforming to IEC 61800-3 2...16 kHz shielded motor cable|conducted emissions with integrated EMC filter environment 1 category C1 conforming to IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m|conducted emissions with additional EMC filter environment 1 category C1 conforming to IEC 61800-3 4...12 kHz shielded motor cable <20 m|conducted emissions with additional EMC filter environment 1 category C2 conforming to IEC 61800-3 4...12 kHz shielded motor cable <50 m|conducted emissions with additional EMC filter environment 2 category C3 conforming to IEC 61800-3 4...12 kHz shielded motor cable <50 m|conducted emissions with integrated EMC filter environment 1 category C2 conforming to IEC 61800-3 4...16 kHz shielded motor cable <5 m|conducted emissions with integrated EMC filter environment 1 category C2 conforming to IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <10 m

Vibration resistance

1 gn (f = 13-200 Hz) conforming to IEC 60068-2-6|1.5 mm peak to peak (f = 3-13 Hz) - drive unmounted on symmetrical DIN rail - conforming to IEC 60068-2-6

Shock resistance

15 gn conforming to IEC 60068-2-27 for 11 ms

Noise level

45 dB

Pollution degree

2

Ambient air transport temperature

-25...70 °C

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

18.000 cm

Package 1 width

18.500 cm

Package 1 length

18.500 cm

Package 1 weight

1.767 kg

Unit type of package 2

S06

Number of units in package 2

30

Package 2 height

75.000 cm

Package 2 width

60.000 cm

Package 2 length

80.000 cm

Package 2 weight

65.950 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • End of Life Manual

  • Operating Manuals

  • Declaration of Conformity

  • Certificates (MSDS)

  • eTechPub

  • Software - Data Library

Frequently Asked Questions

hide show

What is a good source of information for the ATV12?

Issue:
Looking for ATV12 information

Product Line:
Altivar 12

Environment:
All models and serial numbers

Cause:
Information is needed for installation and programming.

Resolution:
User manual is document number BBV28581.  This manual includes instructions for installing the drive, connecting the control wiring, programming and troubleshooting.
https://www.schneider-electric.us/en/download/document/BBV28581/