Colour ()
- 1 PCE 0
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
Item Number: MX9R3232

Colour ()
- 1 PCE 0
Datasheet

For MX9R3232
Ultimate Efficiency and Professional Finish
- MAX9 takes the definition of a busbar to next level with MAXBAR. MAXBAR helps to improve installation speed by up to 15 times when compared to using cables for feeding RCBOs
- With MAXBAR, no cable connections are needed to feed final sub-circuits protected by an RCBO or AFDD - it picks up the active feed from main switch and distributes both active & neutral across all type of Clipsal RCBOs and AFDDs
MAX Innovation & Performance
- Innovation is at the core of everything at Clipsal. MAX9 is no exception to that. MAX9 brings in Arc Fault Detection Device (AFDD) to help take the safety of Australian homes to next level
- Enjoy best-in-class performance with 100A rated system. MAX9 products are designed for tough Aussie conditions with operating temperature ranging from -25 Deg C to +70 Deg C with derating
- When it comes to circuit protection, it all comes down to what's on the inside. MAX9 breakers are solidly built and designed to endure 20K mechanical cycles and 10K electrical cycles*
Peace of Mind
- Amendment 2 of "Wiring rules" mandate type A RCDs from 2023. All RCBOs and RCDs in MAX9 range are already type A so that you can be future ready
- MAX9 system comes type tested as per the requirements of AS/NZS 61439-3 to provide you additional peace of mind
- Clipsal MAX9 range comes with 7 year warranty for the ultimate peace of mind
Simplify Safety & Digital Experience
- Sometimes it could be hard to explain circuit protection category to home owners. MAX9 helps to simplify safety by explaining types of circuit protection to home owners with simple pictograms
- MAX9 range takes the digital experience to next level with QR codes on each product to easily access all technical information like specifications, brochures, installation instructions, FAQs and videos
Specifications
Design
Range
Product or component type
Warranty
Physical
[in] rated current
[ue] rated operational voltage
Height
Width
Depth
Net weight
Connections - terminals
- tunnel type terminal - 1...16 mm² - rigid
- tunnel type terminal - 1...10 mm² - flexible
Standards
- IEC 61009-2-2
- EN/IEC 61009-1
- AS/NZS 61009.1
Ip degree of protection
Ambient air temperature for operation
China rohs regulation
Environmental disclosure
Circularity profile
Others
Package 1 bare product quantity
Package 2 bare product quantity
Poles description
Number of protected poles
Network type
Network frequency
Curve code
Earth-leakage sensitivity
Earth-leakage protection class
Earth-leakage protection time delay
Breaking capacity
Limitation class
[ui] rated insulation voltage
[uimp] rated impulse withstand voltage
9 mm pitches
Comb busbar and distribution block compatibility
Temperature derating table
- -25 °C ( 38 A )
- -20 °C ( 37.5 A )
- -15 °C ( 37 A )
- -10 °C ( 36.4 A )
- -5 °C ( 35.9 A )
- 0 °C ( 35.4 A )
- 5 °C ( 34.8 A )
- 10 °C ( 34.3 A )
- 15 °C ( 33.7 A )
- 20 °C ( 33.2 A )
- 25 °C ( 32.6 A )
- 30 °C ( 32 A )
- 35 °C ( 31.4 A )
- 40 °C ( 30.8 A )
- 45 °C ( 30.2 A )
- 50 °C ( 29.5 A )
- 55 °C ( 28.9 A )
- 60 °C ( 28.2 A )
- 65 °C ( 27.5 A )
- 70 °C ( 26.8 A )
Grid distance
Quality labels
Pollution degree
Overvoltage category
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Packaging made with recycled cardboard
Packaging without single use plastic
Take-back
Take-back
Product contributes to saved and avoided emissions
Removable battery
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Product Brochures
-
Environmental Disclosure
-
End of Life Manual
-
Installation Instruction
-
Certificates (MSDS)
MAX9 - RCBO 1PN C 10A to 40A 30mA 2MOD 3D Simplified - 3D CAD
VERSION
1.0
DATE
04 Oct 2023
REVISION
1.0
MAX9 The ultimate in circuit protection
VERSION
1.0
DATE
21 Mar 2023
REVISION
1.0
Easy9 RCBO 1PN C 16A 30mA AC SLIM
VERSION
1.0
DATE
13 Aug 2024
REVISION
1.0
DPNN 40A + Vigi DPN ELE 30mA AC
VERSION
1.0
DATE
05 Jul 2024
REVISION
1.0
DPNN 40A + Vigi DPN ELE 30mA AC
VERSION
1.0
DATE
07 Aug 2024
REVISION
1.0
Instruction sheet - Residual current circuit breaker with overcurrent protection (RCBO) 2 Modules Type A
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
MAX9 - RCBO 1PN C 10A to 40A 30mA 2MOD 3D Simplified - 3D CAD
VERSION
1.0
DATE
04 Oct 2023
REVISION
1.0
MAX9 The ultimate in circuit protection
VERSION
1.0
DATE
21 Mar 2023
REVISION
1.0
Easy9 RCBO 1PN C 16A 30mA AC SLIM
VERSION
1.0
DATE
13 Aug 2024
REVISION
1.0
DPNN 40A + Vigi DPN ELE 30mA AC
VERSION
1.0
DATE
05 Jul 2024
REVISION
1.0
DPNN 40A + Vigi DPN ELE 30mA AC
VERSION
1.0
DATE
07 Aug 2024
REVISION
1.0
Instruction sheet - Residual current circuit breaker with overcurrent protection (RCBO) 2 Modules Type A
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
- Page 1 / 2
- Page 2 / 2






Fast installation speed with unmatched flexibility
- Up to 15 times faster installation with MAXBAR
- Separate indicator windows for MCB trip or RCD trip for easy diagnosis in case of tripping of device.
- Compatible with multiple types of screw-drivers with combination head screws
- Double locking clip for ease of installation or removal from MAXBAR
Helps to provide additional safety
- Type A RCD to sense a.c. as well as pulsating d.c.
- Option of Type A-SI for high dependency applications
- Switching of both active and neutral contacts
- Positive contact Indicator on toggle that indicates opening of all poles
Peace of mind with complete solution
- Short circuit breaking capacity of 6kA
- Caters for current ratings from 10A to 40A (32A for type A-SI)
- Designed for touch Aussie conditions with operating temperature range of -25 Deg C to +70 Deg C (derating applies)
- Designed to last with endurance performance of 10K electrical cycles and 20K mechanical cycles
- Compatible with A9A26970 padlocking device
Related products

DISCONTINUED
MX9R3210S
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 10A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
1PN, 10A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD

DISCONTINUED
MX9R3210
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 10A, 30mA, C Curve, 6000A, A Type, 2 MOD
1PN, 10A, 30mA, C Curve, 6000A, A Type, 2 MOD

DISCONTINUED
MX9R3216S
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 16A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
1PN, 16A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD

DISCONTINUED
MX9R3216
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 16A, 30mA, C Curve, 6000A, A Type, 2 MOD
1PN, 16A, 30mA, C Curve, 6000A, A Type, 2 MOD

DISCONTINUED
MX9R3220S
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 20A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
1PN, 20A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD

DISCONTINUED
MX9R3220
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 20A, 30mA, C Curve, 6000A, A Type, 2 MOD
1PN, 20A, 30mA, C Curve, 6000A, A Type, 2 MOD

DISCONTINUED
MX9R3225S
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 25A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
1PN, 25A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD

DISCONTINUED
MX9R3225
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 25A, 30mA, C Curve, 6000A, A Type, 2 MOD
1PN, 25A, 30mA, C Curve, 6000A, A Type, 2 MOD

DISCONTINUED
MX9R3232S
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 32A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
1PN, 32A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD

DISCONTINUED
MX9R3240
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 40A, 30mA, C Curve, 6000A, A Type, 2 MOD
1PN, 40A, 30mA, C Curve, 6000A, A Type, 2 MOD

DISCONTINUED
MX9R3132
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 32A, 30mA, C Curve, 6000A, A Type, SLIM
1PN, 32A, 30mA, C Curve, 6000A, A Type, SLIM
Recently viewed

DISCONTINUED
MX9R3232
MAX9, Residual Current Breaker with Overcurrent Protection (RCBO), 1PN, 32A, 30mA, C Curve, 6000A, A Type, 2 MOD
1PN, 32A, 30mA, C Curve, 6000A, A Type, 2 MOD

DISCONTINUED
A9D11210
Acti9, Residual current breaker with overcurrent protection (RCBO), iC60H2 RCBO, 2P, 10A, 30mA, A type, 10000A

DISCONTINUED
A9D11225